Literature DB >> 20920423

Quantifying the composition of human skin for glucose sensor development.

Willemijn Groenendaal1, Golo von Basum, Kristiane A Schmidt, Peter A J Hilbers, Natal A W van Riel.   

Abstract

BACKGROUND: Glucose is heterogeneously distributed within human skin. In order to develop a glucose measurement method for human skin, both a good quantification of the different compartments of human skin and an understanding of glucose transport processes are essential. This study focused on the composition of human skin. In addition, the extent to which intersubject variability in skin composition alters glucose dynamics in human skin was investigated.
METHODS: To quantify the composition of the three layers of human skin-epidermis, dermis, and adipose tissue-cell and blood vessel volumes were calculated from skin biopsies. These results were combined with data from the literature. The composition was applied as input for a previously developed computational model that calculates spatiotemporal glucose dynamics in human skin. The model was used to predict the physiological effects of intersubject variability in skin composition on glucose profiles in human skin.
RESULTS: According to the model, the lag time of glucose dynamics in the epidermis was sensitive to variation in the volumes of interstitial fluid, cells, and blood of all layers. Data showed most variation/uncertainty in the volume composition of the adipose tissue. This variability mainly influences the dynamics in the adipose tissue.
CONCLUSIONS: This study identified the intersubject variability in human skin composition. The study shows that this variability has significant influence on the glucose dynamics in human skin. In addition, it was determined which volumes are most critical for the quantification and interpretation of measurements in the different layers.
© 2010 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20920423      PMCID: PMC2956818          DOI: 10.1177/193229681000400502

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  28 in total

Review 1.  The cutaneous microcirculation.

Authors:  I M Braverman
Journal:  J Investig Dermatol Symp Proc       Date:  2000-12

Review 2.  The lymphatic system in body homeostasis: physiological conditions.

Authors:  Waldemar L Olszewski
Journal:  Lymphat Res Biol       Date:  2003       Impact factor: 2.589

Review 3.  Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium.

Authors:  Omar S Khalil
Journal:  Diabetes Technol Ther       Date:  2004-10       Impact factor: 6.118

Review 4.  Interstitial-lymphatic mechanisms in the control of extracellular fluid volume.

Authors:  K Aukland; R K Reed
Journal:  Physiol Rev       Date:  1993-01       Impact factor: 37.312

Review 5.  Variability of insulin absorption and insulin action.

Authors:  Lutz Heinemann
Journal:  Diabetes Technol Ther       Date:  2002       Impact factor: 6.118

Review 6.  Anatomy, histology and immunohistochemistry of normal human skin.

Authors:  Jean Kanitakis
Journal:  Eur J Dermatol       Date:  2002 Jul-Aug       Impact factor: 3.328

7.  Noninvasive glucose monitoring by reverse iontophoresis in vivo: application of the internal standard concept.

Authors:  Anke Sieg; Richard H Guy; M Begoña Delgado-Charro
Journal:  Clin Chem       Date:  2004-05-20       Impact factor: 8.327

8.  Modeling glucose and water dynamics in human skin.

Authors:  W Groenendaal; K A Schmidt; G von Basum; N A W van Riel; P A J Hilbers
Journal:  Diabetes Technol Ther       Date:  2008-08       Impact factor: 6.118

9.  Detection and characterisation of microcirculatory abnormalities in the skin of diabetic patients with microvascular complications.

Authors:  Belinda A Brooks; Susan V McLennan; Stephen M Twigg; Dennis K Yue
Journal:  Diab Vasc Dis Res       Date:  2008-03       Impact factor: 3.291

Review 10.  Lymphatic endothelium: morphological, molecular and functional properties.

Authors:  Michael S Pepper; Mihaela Skobe
Journal:  J Cell Biol       Date:  2003-10-27       Impact factor: 10.539

View more
  15 in total

Review 1.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: theoretical framework.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

2.  Detection of trace glucose on the surface of a semipermeable membrane using a fluorescently labeled glucose-binding protein: a promising approach to noninvasive glucose monitoring.

Authors:  Xudong Ge; Govind Rao; Yordan Kostov; Sunsanee Kanjananimmanont; Rose M Viscardi; Hyung Woo; Leah Tolosa
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

3.  Highly sensitive and specific noninvasive in-vivo alcohol detection using wavelength-modulated differential photothermal radiometry.

Authors:  Xinxin Guo; Khashayar Shojaei-Asanjan; Di Zhang; Koneswaran Sivagurunathan; Qiming Sun; Peng Song; Andreas Mandelis; Bo Chen; Matt Goledzinowski; Qun Zhou; Felix Comeau
Journal:  Biomed Opt Express       Date:  2018-09-05       Impact factor: 3.732

4.  Interstitial fluid physiology as it relates to glucose monitoring technologies: symposium introduction.

Authors:  Natalie A Wisniewski; Uli Klueh; Julie Stenken
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

5.  Pilot study of a prototype minimally invasive intradermal continuous glucose monitor.

Authors:  Ruth S Weinstock; Suzan Bristol; Andrew Armenia; A Chris Gesswein; B Wayne Bequette; John P Willis
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

Review 6.  Microneedles for transdermal diagnostics: Recent advances and new horizons.

Authors:  Gui-Shi Liu; Yifei Kong; Yensheng Wang; Yunhan Luo; Xudong Fan; Xi Xie; Bo-Ru Yang; Mei X Wu
Journal:  Biomaterials       Date:  2019-12-26       Impact factor: 12.479

Review 7.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

8.  Passive Diffusion of Transdermal Glucose: Noninvasive Glucose Sensing Using a Fluorescent Glucose Binding Protein.

Authors:  Sunsanee Kanjananimmanont; Xudong Ge; KarunaSri Mupparapu; Govind Rao; Russell Potts; Leah Tolosa
Journal:  J Diabetes Sci Technol       Date:  2014-01-21

9.  Hydrogel-Forming Microneedle Arrays Allow Detection of Drugs and Glucose In Vivo: Potential for Use in Diagnosis and Therapeutic Drug Monitoring.

Authors:  Ester Caffarel-Salvador; Aaron J Brady; Eyman Eltayib; Teng Meng; Ana Alonso-Vicente; Patricia Gonzalez-Vazquez; Barbara M Torrisi; Eva Maria Vicente-Perez; Karen Mooney; David S Jones; Steven E J Bell; Colin P McCoy; Helen O McCarthy; James C McElnay; Ryan F Donnelly
Journal:  PLoS One       Date:  2015-12-30       Impact factor: 3.240

10.  Integrated hollow microneedle-optofluidic biosensor for therapeutic drug monitoring in sub-nanoliter volumes.

Authors:  Sahan A Ranamukhaarachchi; Celestino Padeste; Matthias Dübner; Urs O Häfeli; Boris Stoeber; Victor J Cadarso
Journal:  Sci Rep       Date:  2016-07-06       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.