Literature DB >> 22173929

Three-dimensional Doppler evaluation of single spherical samples from the placenta: intra- and interobserver reliability.

W P Martins1, J C Lima, A W Welsh, E Araujo Júnior, E Araujo, A H Miyague, F M Filho, N J Raine-Fenning.   

Abstract

OBJECTIVE: To evaluate the intra- and interobserver reliability of assessment of three-dimensional power Doppler (3D-PD) indices from single spherical samples of the placenta.
METHODS: Women with singleton pregnancies at 24-40 weeks' gestation were included. Three scans were independently performed by two observers; Observer 1 performed the first and third scan, intercalated by the scan of Observer 2. The observers independently analyzed the 3D-PD datasets that they had previously acquired using four different methods, each using a spherical sample: random sample extending from basal to chorionic plate; random sample with 2 cm(3) of volume; directed sample to the region subjectively determined as containing more color Doppler signals extending from basal to chorionic plate; or directed sample with 2 cm(3) of volume. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were evaluated in each case. The observers were blinded to their own and each other's results. Additional evaluation was performed according to placental location: anterior, posterior and fundal or lateral. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICC).
RESULTS: Ninety-five pregnancies were included in the analysis. All three placental 3D-PD indices showed only weak to moderate reliability (ICC < 0.66 and ICC < 0.48, intra- and interobserver, respectively). The highest values of ICC were observed when using directed spherical samples from basal to chorionic plate. When analyzed by placental location, we found lower ICCs for lateral and fundal placentae compared to anterior and posterior ones.
CONCLUSION: Intra- and interobserver reliability of assessment of placental 3D-PD indices from single spherical samples in pregnant women greater than 24 weeks' gestation is poor to moderate, and clinical usefulness of these indices is likely to be limited.
Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2012        PMID: 22173929     DOI: 10.1002/uog.11076

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  8 in total

1.  The prediction of radiofrequency ablation zone volume using vascular indices of 3-dimensional volumetric colour Doppler ultrasound in an in vitro blood-perfused bovine liver model.

Authors:  Samuel Chang; Anthony C Lanctot; Martin D McCarter; Katherine M Roberts; Deborah H Glueck; Gerald D Dodd
Journal:  Br J Radiol       Date:  2016-12-07       Impact factor: 3.039

2.  Novel spatial-temporal image correlation derived indices of tissue vascular impedance: A variability study.

Authors:  Linda Wu; Ana Ferreira; Gordon N Stevenson; Jennifer Sanderson; Aditi Mahajan; Neama Meriki; Alec W Welsh
Journal:  Australas J Ultrasound Med       Date:  2017-07-11

3.  Placental vascularization alterations in hypertensive disorders complicating pregnancy (HDCP) and small for gestational age with HDCP using three-dimensional power doppler in a prospective case control study.

Authors:  Ting Yuan; Ting Zhang; Zhen Han
Journal:  BMC Pregnancy Childbirth       Date:  2015-10-05       Impact factor: 3.007

4.  Reduced placental volume and flow in severe growth restricted fetuses.

Authors:  Renata Montes Dourado Abulé; Lisandra Stein Bernardes; Giovana Farina Doro; Seizo Miyadahira; Rossana Pulcinelli Vieira Francisco
Journal:  Clinics (Sao Paulo)       Date:  2016-07       Impact factor: 2.365

5.  Placental location, postpartum hemorrhage and retained placenta in women with a previous cesarean section delivery: a prospective cohort study.

Authors:  Johanna Belachew; Karin Eurenius; Ajlana Mulic-Lutvica; Ove Axelsson
Journal:  Ups J Med Sci       Date:  2017-08-22       Impact factor: 2.384

Review 6.  Update on Color Flow Imaging in Obstetrics.

Authors:  Kwok-Yin Leung; Yung-Liang Wan
Journal:  Life (Basel)       Date:  2022-01-31

7.  Parturient perineal distensibility tolerance assessed by EPI-NO: an observational study.

Authors:  Mary Uchiyama Nakamura; Nelson Sass; Julio Elito Júnior; Carla Dellabarba Petricelli; Sandra Maria Alexandre; Edward Araujo Júnior; Miriam Raquel Diniz Zanetti
Journal:  Einstein (Sao Paulo)       Date:  2014 Jan-Mar

Review 8.  3D Power Doppler vascular indices as a novel technique in assessing the outcome of minimally invasive techniques in uterine fibroids treatment.

Authors:  Anna Stępniak; Piotr Czuczwar
Journal:  Prz Menopauzalny       Date:  2017-12-30
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.