Near-infrared spectroscopy cerebral and somatic (renal) oxygen saturation correlation to continuous venous oxygen saturation via intravenous oximetry catheter.

Gilma A Marimón1, W Keith Dockery, Michael J Sheridan, Swati Agarwal.   

Abstract

PURPOSE: Near-infrared spectroscopy (NIRS) and continuous central venous oxygen saturation (ScvO(2)) via oximetry catheter are 2 modalities available to estimate adequacy of oxygen delivery in postoperative pediatric cardiac patients. Near-infrared spectroscopy measures regional tissue oxygenation and is routinely used in pediatric cardiac surgery patients. By not requiring an invasive catheter, NIRS has the advantage over mixed venous oxygen saturation (SvO(2)) monitoring. An alternative marker of global tissue oxygenation is central venous oxygen saturation (ScvO(2)). A recently developed pediatric-sized oximetric catheter (PediaSat; Edwards Lifesciences, Irvine, CA, USA) functions as a central venous catheter and provides a continuous ScvO(2) reading, an accepted surrogate to SvO(2). To date, the correlation between NIRS and ScvO(2) has not been quantified. The aim of this study was to examine the strength of the bivariate correlation between NIRS and ScvO(2) measurements. DESIGN/
METHODS: Twenty pediatric patients undergoing cardiac surgery had the PediaSat catheter placed with the tip in the superior vena cava and NIRS sensors (cerebral and renal) placed in the operating room per routine protocol. Hourly measurements of NIRS-cerebral (NIRS-C), NIRS-renal, and ScvO(2) readings were recorded for each patient for up to 48 hours postoperatively.
RESULTS: A cumulative total of 630 hours of data were collected. Spearman correlation coefficients for NIRS-renal vs ScvO(2) and NIRS-C vs ScvO(2) measurements were r = 0.38 (P = .09) and r = 0.58 (P< .008), respectively.
CONCLUSIONS: In this small cohort of pediatric patients undergoing heart surgery, there was a moderate but statistically significant correlation between the ScvO(2)-catheter and the NIRS-C values. Further studies are required to determine which oxymetric modality of monitoring cardiac output most aids in the postoperative management of these patients.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22172794     DOI: 10.1016/j.jcrc.2011.10.002

Source DB:  PubMed          Journal:  J Crit Care        ISSN: 0883-9441            Impact factor:   3.425


  11 in total

Review 1.  In vivo validation of cerebral near-infrared spectroscopy: a review.

Authors:  Amalie la Cour; Gorm Greisen; Simon Hyttel-Sorensen
Journal:  Neurophotonics       Date:  2018-11-27       Impact factor: 3.593

2.  Somatic stimulation causes frontoparietal cortical changes in neonates: a functional near-infrared spectroscopy study.

Authors:  Nasser H Kashou; Irfaan A Dar; Kathryn A Hasenstab; Ramzi W Nahhas; Sudarshan R Jadcherla
Journal:  Neurophotonics       Date:  2016-08-17       Impact factor: 3.593

3.  Correlation between Regional Cerebral Saturation and Invasive Cardiac Index Monitoring after Heart Transplantation Surgery.

Authors:  Awni M Al-Subu; Christoph P Hornik; Ira M Cheifetz; Andrew J Lodge; George Ofori-Amanfo
Journal:  J Pediatr Intensive Care       Date:  2018-06-11

4.  [Near-infrared spectroscopy in sepsis therapy : predictor of a low central venous oxygen saturation].

Authors:  C Lichtenstern; C Koch; R Röhrig; B Rosengarten; M Henrich; M A Weigand
Journal:  Anaesthesist       Date:  2012-09-27       Impact factor: 1.041

5.  Low near infrared spectroscopic somatic oxygen saturation at admission is associated with need for lifesaving interventions among unplanned admissions to the pediatric intensive care unit.

Authors:  Binod Balakrishnan; Mahua Dasgupta; Kim Gajewski; Raymond G Hoffmann; Pippa M Simpson; Peter L Havens; Sheila J Hanson
Journal:  J Clin Monit Comput       Date:  2017-03-03       Impact factor: 2.502

Review 6.  Advances in monitoring and management of shock.

Authors:  Haifa Mtaweh; Erin V Trakas; Erik Su; Joseph A Carcillo; Rajesh K Aneja
Journal:  Pediatr Clin North Am       Date:  2013-03-29       Impact factor: 3.278

7.  Near-infrared spectroscopy as continuous real-time monitoring for kidney graft perfusion.

Authors:  Enrico Vidal; Angela Amigoni; Valentina Brugnolaro; Giulia Ghirardo; Piergiorgio Gamba; Andrea Pettenazzo; Giovanni Franco Zanon; Chiara Cosma; Mario Plebani; Luisa Murer
Journal:  Pediatr Nephrol       Date:  2013-12-05       Impact factor: 3.714

8.  Noninvasive monitoring of central venous oxygen saturation by jugular transcutaneous near-infrared spectroscopy in pediatric patients undergoing congenital cardiac surgery

Authors:  Dilek Altun; Abdullah Doğan; Ahmet Arnaz; Adnan Yüksek; Yusuf Kenan Yalçinbaş; Riza Türköz; Tayyar Sarioğlu
Journal:  Turk J Med Sci       Date:  2020-08-26       Impact factor: 0.973

9.  Comparison of bilateral cerebral and somatic tissue oxygenation with near-infrared spectroscopy in cyanotic and acyanotic pediatric patients receiving cardiac surgery.

Authors:  Tulay Candan; Muhammet Candan; Cenk Eray Yildiz; Mehmet Gumustas; Selim Erenturk; Yusuf Kenan Yalcinbas
Journal:  Arch Med Sci Atheroscler Dis       Date:  2020-12-29

10.  Tissue oximetry during cardiac surgery and in the cardiac intensive care unit: A prospective observational trial.

Authors:  Benjamin J Heller; Pranav Deshpande; Joshua A Heller; Patrick McCormick; Hung-Mo Lin; Ruiqi Huang; Gregory Fischer; Menachem M Weiner
Journal:  Ann Card Anaesth       Date:  2018 Oct-Dec