Literature DB >> 22172094

Three-dimensional accuracy of guided implant placement: indirect assessment of clinical outcomes.

Susanne Platzer1, Georg Bertha, Alexander Heschl, Walther A Wegscheider, Martin Lorenzoni.   

Abstract

PURPOSE: Precise preoperative implant planning and its exact intraoperative transfer are crucial for successful implant-supported rehabilitation of partially or completely edentulous patients. In the present pilot study, optical laser scanning was used to evaluate deviations between three-dimensional computer-assisted planned and actual implant positions by indirect methods.
MATERIAL AND METHODS: Five patients receiving a total of 15 implants were included in this study. The used planning software was SimPlant 12.0 (Materialise Dental, Leuven, Belgium) to visualize the implant positions, and with an appropriate guided surgery protocol (Navigator™, Biomet 3i, Palm Beach Gardens, FL, USA) implant positions were implemented via tooth-supported stereolithografic surgical guides. All implants (Osseotite™, Biomet 3i) were inserted in a flapless approach and immediately provided with prefabricated temporary splinted restorations. Intraoral pickup impressions were taken postoperatively, and the implant positions of the master casts were compared with presurgical casts. Implant replica deviations were evaluated by three-dimensional optical laser scanning providing distances and angulations between implant replicas.
RESULTS: Overall, the postsurgical implant replica positions were found to deviate from the positions in the preoperative cast by a mean of 0.46 ± 0.21 mm (range: 0.09-0.85 mm). Positional deviations were 0.27 ± 0.19 mm (range: 0.04-0.60 mm) along the x-axis representing the buccal-lingual directions, 0.15 ± 0.13 mm (range: 0.0-0.34 mm) along the y-axis representing the ventrodorsal direction, and 0.28 ± 0.19 mm (range: 0.02-0.59 mm) along the z-axis representing cranial and apical directions. Rotational deviations amounted to 14.04 ± 11.6° (range: 0.09-36.47°).
CONCLUSIONS: The results of this pilot study demonstrate precise transfer of implant replica position by means of simulated guided implant insertion into a preoperative cast and a postoperative cast obtained from impressioning. Further studies are needed to identify appropriate evaluation techniques and mechanisms to increase the transfer precision of three-dimensional planning and guiding systems.
© 2011 Wiley Periodicals, Inc.

Entities:  

Keywords:  accuracy; dental implants; guided implant surgery; immediate provisionalization; laser scan

Mesh:

Substances:

Year:  2011        PMID: 22172094     DOI: 10.1111/j.1708-8208.2011.00406.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  8 in total

1.  3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study.

Authors:  Sigmar Schnutenhaus; Cornelia Edelmann; Heike Rudolph; Jens Dreyhaupt; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2018-01-22       Impact factor: 3.573

2.  Comparison of Different Types of Static Computer-Guided Implant Surgery in Varying Bone Inclinations.

Authors:  Pisut Thangwarawut; Pokpong Amornvit; Dinesh Rokaya; Sirichai Kiattavorncharoen
Journal:  Materials (Basel)       Date:  2022-04-20       Impact factor: 3.748

Review 3.  Computerized implant-dentistry: Advances toward automation.

Authors:  Minkle Gulati; Vishal Anand; Sanjeev Kumar Salaria; Nikil Jain; Shilpi Gupta
Journal:  J Indian Soc Periodontol       Date:  2015 Jan-Feb

4.  Three-dimensional computer-guided implant placement in oligodontia.

Authors:  Marieke A P Filius; Joep Kraeima; Arjan Vissink; Krista I Janssen; Gerry M Raghoebar; Anita Visser
Journal:  Int J Implant Dent       Date:  2017-07-08

5.  Validation of an Intra-Oral Scan Method Versus Cone Beam Computed Tomography Superimposition to Assess the Accuracy between Planned and Achieved Dental Implants: A Randomized In Vitro Study.

Authors:  Alessio Franchina; Luigi V Stefanelli; Fabio Maltese; George A Mandelaris; Alessandro Vantaggiato; Michele Pagliarulo; Nicola Pranno; Edoardo Brauner; Francesca De Angelis; Stefano Di Carlo
Journal:  Int J Environ Res Public Health       Date:  2020-12-14       Impact factor: 3.390

6.  Multivariate analysis of causal factors influencing accuracy of guided implant surgery for partial edentulism: a retrospective clinical study.

Authors:  Atsushi Matsumura; Tamaki Nakano; Shinji Ono; Akihiro Kaminaka; Hirofumi Yatani; Daijiro Kabata
Journal:  Int J Implant Dent       Date:  2021-04-19

7.  The implant position accuracy between using only surgical drill guide and surgical drill guide with implant guide in fully digital workflow: a randomized clinical trial.

Authors:  Chalermchai Ngamprasertkit; Weerapan Aunmeungthong; Pathawee Khongkhunthian
Journal:  Oral Maxillofac Surg       Date:  2021-06-23

8.  Implant Restoration of Edentulous Jaws with 3D Software Planning, Guided Surgery, Immediate Loading, and CAD-CAM Full Arch Frameworks.

Authors:  Silvio Mario Meloni; Giacomo De Riu; Milena Pisano; Francesco Maria Lolli; Alessandro Deledda; Guglielmo Campus; Antonio Tullio
Journal:  Int J Dent       Date:  2013-07-29