Literature DB >> 22171359

Cardiac output measurement with transpulmonary ultrasound dilution is feasible in the presence of a left-to-right shunt: a validation study in lambs.

S L Vrancken1, W P de Boode, J C Hopman, S K Singh, K D Liem, A F van Heijst.   

Abstract

BACKGROUND: Cardiac output (CO) monitoring remains complex in newborns as most of the current technologies fail to accurately measure systemic blood flow in the presence of shunts. We validated CO measurements using transpulmonary ultrasound dilution (TPUD) in a neonatal lamb model with a left-to-right shunt.
METHODS: Regular arterial and central venous catheters were inserted into seven lambs (3.5-8.3 kg). A surgically constructed left-to-right aorto-pulmonary Gore-Tex(®) shunt was intermittently opened and closed, while CO was manipulated by creating haemorrhagic hypotension. CO measurements with TPUD (COtpud) were compared with those obtained by an ultrasonic transit-time flow probe positioned around the main pulmonary artery (COufp).
RESULTS: We performed 72 sessions of three paired CO measurements. The mean COufp was 1.00 litre min(-1) (range 0.47-1.75 litre min(-1)) and mean COtpud 1.05 litre min(-1) (range 0.54-1.87 litre min(-1)). With an open shunt, the mean Qp/Qs ratio was 1.8 (range 1.3-2.6). A comparison between COufp and COtpud showed a mean bias (sd) of 0.03 (0.09) and 0.07 (0.10) litre min(-1), respectively, for measurements with a closed and an open shunt. The percentage error was 18% and 20% for measurements with a closed and an open shunt. Polar plot analysis showed good trending ability for both closed and open shunt groups.
CONCLUSIONS: TPUD is a reliable technology to measure CO in the presence of a left-to-right shunt.

Entities:  

Mesh:

Year:  2011        PMID: 22171359     DOI: 10.1093/bja/aer401

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  8 in total

1.  Hemodynamic volumetry using transpulmonary ultrasound dilution (TPUD) technology in a neonatal animal model.

Authors:  Sabine L Vrancken; Arno F van Heijst; Jeroen C Hopman; Kian D Liem; Johannes G van der Hoeven; Willem P de Boode
Journal:  J Clin Monit Comput       Date:  2014-12-14       Impact factor: 2.502

2.  Gold standard must be solid gold.

Authors:  W P de Boode; S L Vrancken; J Lemson; A Nusmeier; S M Tibby
Journal:  Intensive Care Med       Date:  2013-04-19       Impact factor: 17.440

3.  Feasibility and Accuracy of Cardiac Right-to-Left-Shunt Detection in Children by New Transpulmonary Ultrasound Dilution Method.

Authors:  Martin Boehne; Mathias Baustert; Verena Paetzel; Dietmar Boethig; Harald Köditz; Nils Dennhardt; Philipp Beerbaum; Harald Bertram
Journal:  Pediatr Cardiol       Date:  2016-11-08       Impact factor: 1.655

4.  Continuous cardiac output measured with a Swan-Ganz catheter reacts too slowly in animal experiments with sudden circulatory failure.

Authors:  Sigríður Olga Magnúsdóttir; Carsten Simonsen; Bodil Steen Rasmussen; Peter Enemark Lund; Benedict Kjaergaard
Journal:  Animal Model Exp Med       Date:  2022-06-06

5.  Accuracy of the transpulmonary ultrasound dilution method for detection of small anatomic shunts.

Authors:  R Saxena; N Krivitski; K Peacock; A Durward; J M Simpson; S M Tibby
Journal:  J Clin Monit Comput       Date:  2014-09-21       Impact factor: 2.502

Review 6.  Neonatal Hemodynamics: From Developmental Physiology to Comprehensive Monitoring.

Authors:  Sabine L Vrancken; Arno F van Heijst; Willem P de Boode
Journal:  Front Pediatr       Date:  2018-04-05       Impact factor: 3.418

7.  Estimation of intracardiac shunts in young children with a novel indicator dilution technology.

Authors:  Theodor Skuli Sigurdsson; Lars Lindberg
Journal:  Sci Rep       Date:  2020-01-28       Impact factor: 4.379

8.  Estimation of extravascular lung water using the transpulmonary ultrasound dilution (TPUD) method: a validation study in neonatal lambs.

Authors:  S L Vrancken; A Nusmeier; J C Hopman; K D Liem; J G van der Hoeven; J Lemson; A F van Heijst; W P de Boode
Journal:  J Clin Monit Comput       Date:  2015-11-12       Impact factor: 2.502

  8 in total