BACKGROUND: Cardiac output (CO) monitoring remains complex in newborns as most of the current technologies fail to accurately measure systemic blood flow in the presence of shunts. We validated CO measurements using transpulmonary ultrasound dilution (TPUD) in a neonatal lamb model with a left-to-right shunt. METHODS: Regular arterial and central venous catheters were inserted into seven lambs (3.5-8.3 kg). A surgically constructed left-to-right aorto-pulmonary Gore-Tex(®) shunt was intermittently opened and closed, while CO was manipulated by creating haemorrhagic hypotension. CO measurements with TPUD (COtpud) were compared with those obtained by an ultrasonic transit-time flow probe positioned around the main pulmonary artery (COufp). RESULTS: We performed 72 sessions of three paired CO measurements. The mean COufp was 1.00 litre min(-1) (range 0.47-1.75 litre min(-1)) and mean COtpud 1.05 litre min(-1) (range 0.54-1.87 litre min(-1)). With an open shunt, the mean Qp/Qs ratio was 1.8 (range 1.3-2.6). A comparison between COufp and COtpud showed a mean bias (sd) of 0.03 (0.09) and 0.07 (0.10) litre min(-1), respectively, for measurements with a closed and an open shunt. The percentage error was 18% and 20% for measurements with a closed and an open shunt. Polar plot analysis showed good trending ability for both closed and open shunt groups. CONCLUSIONS: TPUD is a reliable technology to measure CO in the presence of a left-to-right shunt.
BACKGROUND: Cardiac output (CO) monitoring remains complex in newborns as most of the current technologies fail to accurately measure systemic blood flow in the presence of shunts. We validated CO measurements using transpulmonary ultrasound dilution (TPUD) in a neonatal lamb model with a left-to-right shunt. METHODS: Regular arterial and central venous catheters were inserted into seven lambs (3.5-8.3 kg). A surgically constructed left-to-right aorto-pulmonary Gore-Tex(®) shunt was intermittently opened and closed, while CO was manipulated by creating haemorrhagic hypotension. CO measurements with TPUD (COtpud) were compared with those obtained by an ultrasonic transit-time flow probe positioned around the main pulmonary artery (COufp). RESULTS: We performed 72 sessions of three paired CO measurements. The mean COufp was 1.00 litre min(-1) (range 0.47-1.75 litre min(-1)) and mean COtpud 1.05 litre min(-1) (range 0.54-1.87 litre min(-1)). With an open shunt, the mean Qp/Qs ratio was 1.8 (range 1.3-2.6). A comparison between COufp and COtpud showed a mean bias (sd) of 0.03 (0.09) and 0.07 (0.10) litre min(-1), respectively, for measurements with a closed and an open shunt. The percentage error was 18% and 20% for measurements with a closed and an open shunt. Polar plot analysis showed good trending ability for both closed and open shunt groups. CONCLUSIONS: TPUD is a reliable technology to measure CO in the presence of a left-to-right shunt.
Authors: Sabine L Vrancken; Arno F van Heijst; Jeroen C Hopman; Kian D Liem; Johannes G van der Hoeven; Willem P de Boode Journal: J Clin Monit Comput Date: 2014-12-14 Impact factor: 2.502
Authors: Martin Boehne; Mathias Baustert; Verena Paetzel; Dietmar Boethig; Harald Köditz; Nils Dennhardt; Philipp Beerbaum; Harald Bertram Journal: Pediatr Cardiol Date: 2016-11-08 Impact factor: 1.655
Authors: S L Vrancken; A Nusmeier; J C Hopman; K D Liem; J G van der Hoeven; J Lemson; A F van Heijst; W P de Boode Journal: J Clin Monit Comput Date: 2015-11-12 Impact factor: 2.502