Hemodynamic volumetry using transpulmonary ultrasound dilution (TPUD) technology in a neonatal animal model.

Sabine L Vrancken1, Arno F van Heijst2, Jeroen C Hopman3, Kian D Liem2, Johannes G van der Hoeven4, Willem P de Boode2.   

Abstract

To analyze changes in cardiac output and hemodynamic volumes using transpulmonary ultrasound dilution (TPUD) in a neonatal animal model under different hemodynamic conditions. 7 lambs (3.5-8.3 kg) under general anesthesia received arterial and central venous catheters. A Gore-Tex(®) shunt was surgically inserted between the descending aorta and the left pulmonary artery to mimic a patent ductus arteriosus. After shunt opening and closure, induced hemorrhagic hypotension (by repetitive blood withdrawals) and repetitive volume challenges, the following parameters were assessed using TPUD: cardiac output, active circulating volume index (ACVI), central blood volume index (CBVI) and total end-diastolic volume index (TEDVI). 27 measurement sessions were analyzed. After shunt opening, there was a significant increase in TEDVI and a significant decrease in cardiac output with minimal change in CBVI and ACVI. With shunt closure, these results reversed. After progressive hemorrhage, cardiac output and all volumes decreased significantly, except for ACVI. Following repetitive volume resuscitation, cardiac output increased and all hemodynamic volumes increased significantly. Correlations between changes in COufp and changes in hemodynamic volumes (ACVI 0.83; CBVI 0.84 and TEDVI 0.78 respectively) were (slightly) better than between changes in COufp and changes in heart rate (0.44) and central venous pressure (0.7). Changes in hemodynamic volumes using TPUD were as expected under different conditions. Hemodynamic volumetry using TPUD might be a promising technique that has the potential to improve the assessment and interpretation of the hemodynamic status in critically ill newborns and children.

Entities:  

Keywords:  Cardiac output; Child; Ductus arteriosus; Hemodynamic volumes; Infant; Newborn; Transpulmonary ultrasound dilution technique

Mesh:

Substances:

Year:  2014        PMID: 25500953     DOI: 10.1007/s10877-014-9647-6

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  26 in total

1.  Estimation of cardiac output in calves and sheep by the dye and Fick oxygen techniques.

Authors:  C M STOWE; A L GOOD
Journal:  Am J Physiol       Date:  1960-05

2.  Application of ultrasound dilution technology for cardiac output measurement: Cerebral and systemic hemodynamic consequences in a juvenile animal model.

Authors:  Willem P de Boode; Arno F J van Heijst; Jeroen C W Hopman; Ronald B Tanke; Hans G van der Hoeven; K Djien Liem
Journal:  Pediatr Crit Care Med       Date:  2010-09       Impact factor: 3.624

3.  Ultrasound dilution: an accurate means of determining cardiac output in children.

Authors:  Ivory Crittendon; William J Dreyer; Jamie A Decker; Jeffrey J Kim
Journal:  Pediatr Crit Care Med       Date:  2012-01       Impact factor: 3.624

Review 4.  Cardiac output monitoring.

Authors:  Eric E C de Waal; Frank Wappler; Wolfgang F Buhre
Journal:  Curr Opin Anaesthesiol       Date:  2009-02       Impact factor: 2.706

5.  Flow-regulated extracorporeal arteriovenous tubing loop for cardiac output measurements by ultrasound velocity dilution: validation in post-cardiac surgery intensive care unit patients.

Authors:  Alexsandr A Eremenko; Perviz N Safarov
Journal:  ASAIO J       Date:  2010 Nov-Dec       Impact factor: 2.872

6.  Cardiac output measurement using an ultrasound dilution method: a validation study in ventilated piglets.

Authors:  Willem P de Boode; Arno F J van Heijst; Jeroen C W Hopman; Ronald B Tanke; Hans G van der Hoeven; Kian D Liem
Journal:  Pediatr Crit Care Med       Date:  2010-01       Impact factor: 3.624

7.  Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmonary indicator dilution in critically ill neonates and infants.

Authors:  Holger Schiffmann; Bernhard Erdlenbruch; Dominique Singer; Sybille Singer; Egbert Herting; Andreas Hoeft; Wolfgang Buhre
Journal:  J Cardiothorac Vasc Anesth       Date:  2002-10       Impact factor: 2.628

Review 8.  Bedside assessment of extravascular lung water by dilution methods: temptations and pitfalls.

Authors:  Frédéric Michard
Journal:  Crit Care Med       Date:  2007-04       Impact factor: 7.598

9.  Theory and in vitro validation of a new extracorporeal arteriovenous loop approach for hemodynamic assessment in pediatric and neonatal intensive care unit patients.

Authors:  Nikolai M Krivitski; Victor V Kislukhin; Naveen V Thuramalla
Journal:  Pediatr Crit Care Med       Date:  2008-07       Impact factor: 3.624

10.  Comparison of a new cardiac output ultrasound dilution method with thermodilution technique in adult patients under general anesthesia.

Authors:  Masato Tsutsui; Nobuhiro Matsuoka; Takehiko Ikeda; Yoshimitsu Sanjo; Tomiei Kazama
Journal:  J Cardiothorac Vasc Anesth       Date:  2009-05-22       Impact factor: 2.628

View more
  4 in total

Review 1.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

Review 2.  Neonatal Hemodynamics: From Developmental Physiology to Comprehensive Monitoring.

Authors:  Sabine L Vrancken; Arno F van Heijst; Willem P de Boode
Journal:  Front Pediatr       Date:  2018-04-05       Impact factor: 3.418

3.  Estimation of intracardiac shunts in young children with a novel indicator dilution technology.

Authors:  Theodor Skuli Sigurdsson; Lars Lindberg
Journal:  Sci Rep       Date:  2020-01-28       Impact factor: 4.379

4.  Indexing haemodynamic variables in young children.

Authors:  Theodor S Sigurdsson; Lars Lindberg
Journal:  Acta Anaesthesiol Scand       Date:  2020-10-30       Impact factor: 2.105

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.