Literature DB >> 22171358

Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement.

C Ilies1, M Bauer, P Berg, J Rosenberg, J Hedderich, B Bein, J Hinz, R Hanss.   

Abstract

BACKGROUND: Arterial pressure (AP) monitoring should be accurate, easy to use, free of risks, and ideally continuous. The continuous non-invasive arterial pressure (CNAP) device is non-invasive and provides continuous pressure readings. This study was performed to compare the agreement of CNAP and invasive AP monitoring.
METHODS: Ninety patients undergoing surgery under general anaesthesia were enrolled. Invasive pressure monitoring was established at the radial artery. CNAP monitoring using a finger sensor recording was begun before induction of anaesthesia. Statistical analysis was conducted with the Bland-Altman method for comparisons of repeated measures.
RESULTS: We obtained 16 843 valid pressure readings from 85 patients. Mean (sd) bias during maintenance of anaesthesia was: systolic AP: 4.2 (16.5) mm Hg; mean AP (MAP): -4.3 (10.4) mm Hg; and diastolic AP: -5.8 (6) mm Hg. The results of a subgroup analysis of patients who had a mean intra-arterial pressure of <70 mm Hg were as follows: systolic pressure: -0.3 (9.7) mm Hg; mean pressure: -6.8 (7.6) mm Hg; and diastolic pressure: -7.9 (7.2) mm Hg. Bias and percentage error during the induction period were greater in both the main and subgroup analyses, probably due to recalibration being omitted after induction.
CONCLUSIONS: The CNAP monitor showed an acceptable agreement and was interchangeable with invasive pressure monitoring for MAP during normotensive conditions. During induction of anaesthesia and when the AP was low, the agreement was less good and interchangeability was not achieved. These results suggest that CNAP is not statistically equivalent to invasive monitoring during all periods of anaesthesia but may be a useful additional AP monitor.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22171358     DOI: 10.1093/bja/aer394

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  41 in total

1.  The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients.

Authors:  Bernd Saugel; Florian Fassio; Alexander Hapfelmeier; Agnes S Meidert; Roland M Schmid; Wolfgang Huber
Journal:  Intensive Care Med       Date:  2012-06-29       Impact factor: 17.440

2.  Continuous noninvasive arterial pressure measurement using the volume clamp method: an evaluation of the CNAP device in intensive care unit patients.

Authors:  Julia Y Wagner; Ileana Negulescu; Miriam Schöfthaler; Alexander Hapfelmeier; Agnes S Meidert; Wolfgang Huber; Roland M Schmid; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2015-03-01       Impact factor: 2.502

3.  Baroreflex dysfunction and augmented sympathetic nerve responses during mental stress in veterans with post-traumatic stress disorder.

Authors:  Jeanie Park; Paul J Marvar; Peizhou Liao; Melanie L Kankam; Seth D Norrholm; Ryan M Downey; S Ashley McCullough; Ngoc-Anh Le; Barbara O Rothbaum
Journal:  J Physiol       Date:  2017-06-14       Impact factor: 5.182

Review 4.  Non-invasive continuous blood pressure monitoring: a review of current applications.

Authors:  Elena Chung; Guo Chen; Brenton Alexander; Maxime Cannesson
Journal:  Front Med       Date:  2013-01-23       Impact factor: 4.592

5.  Continuous non-invasive monitoring improves blood pressure stability in upright position: randomized controlled trial.

Authors:  Jan Benes; Alena Simanova; Tereza Tovarnicka; Silvie Sevcikova; Jakub Kletecka; Jan Zatloukal; Richard Pradl; Ivan Chytra; Eduard Kasal
Journal:  J Clin Monit Comput       Date:  2014-05-20       Impact factor: 2.502

6.  Continuous blood pressure monitoring via non-invasive radial artery applanation tonometry and invasive arterial catheter demonstrates good agreement in patients undergoing colon carcinoma surgery.

Authors:  Jing Sun; Hanjian Chen; Jun Zheng; Bin Mao; Shengmei Zhu; Jingyi Feng
Journal:  J Clin Monit Comput       Date:  2016-12-20       Impact factor: 2.502

7.  A novel non-invasive blood pressure waveform measuring system compared to Millar applanation tonometry.

Authors:  Sándor Földi; Tamás Horváth; Flóra Zieger; Péter Sótonyi; György Cserey
Journal:  J Clin Monit Comput       Date:  2017-10-04       Impact factor: 2.502

8.  Cardiovascular responses to a glucose drink in young male individuals with overweight/obesity and mild alterations in glucose metabolism, but without impaired glucose tolerance.

Authors:  Cathriona R Monnard; Erik Konrad Grasser
Journal:  Eur J Nutr       Date:  2019-10-21       Impact factor: 5.614

9.  Exercise pressor response and arterial baroreflex unloading during exercise in chronic kidney disease.

Authors:  Jeanie Park; Arshed A Quyyumi; Holly R Middlekauff
Journal:  J Appl Physiol (1985)       Date:  2012-12-13

10.  Continuous noninvasive cardiac output determination using the CNAP system: evaluation of a cardiac output algorithm for the analysis of volume clamp method-derived pulse contour.

Authors:  Julia Y Wagner; Julian Grond; Jürgen Fortin; Ileana Negulescu; Miriam Schöfthaler; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2015-07-31       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.