Literature DB >> 22167023

Clinical indices for orthodontic mini-implants.

Mitsuru Motoyoshi1.   

Abstract

Orthodontic mini-implants were recently developed and have been widely used in clinics. However, loosening of mini-implants, as well as infection and swelling of mucosal tissue at the placement site, are often observed during orthodontic treatment. Thus, clinical indices are greatly needed for the safe use of orthodontic mini-implants. This article presents information on mini-implants and offers suggestions on indications, placement technique, optimum design, and evaluation of the placement site for mini-implants. The author concludes that 1) mini-implants should be left in the placement site for 3 months before loading to allow for a healing period, which increases the success rate in adolescent patients, 2) placement torque should be considered when tightening mini-implants into bone, as excessively high or low torque results in low stability, 3) mini-implants with optimal screws should be placed in the correct position, and 4) a prepared site should be established in an area with a cortical bone thickness of greater than 1.0 mm, to improve the success rate. Finally, the vector of orthodontic forces in the arrangement with the center of resistance of the entire dental arch should be considered when developing treatment goals.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22167023     DOI: 10.2334/josnusd.53.407

Source DB:  PubMed          Journal:  J Oral Sci        ISSN: 1343-4934            Impact factor:   1.556


  8 in total

1.  Comparison of interradicular distances and cortical bone thickness in Thai patients with Class I and Class II skeletal patterns using cone-beam computed tomography.

Authors:  Nattida Khumsarn; Virush Patanaporn; Apirum Janhom; Dhirawat Jotikasthira
Journal:  Imaging Sci Dent       Date:  2016-06-23

2.  A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition.

Authors:  Mayur S Bhattad; Sudhindra Baliga; Pavan Vibhute
Journal:  Dental Press J Orthod       Date:  2015 Mar-Apr

3.  Root proximity of miniscrews at a variety of maxillary and mandibular buccal sites: Reliability of panoramic radiography.

Authors:  Jae-Hwa An; Yong-Il Kim; Seong-Sik Kim; Soo-Byung Park; Woo-Sung Son; Sung-Hun Kim
Journal:  Angle Orthod       Date:  2019-03-11       Impact factor: 2.079

4.  Three-dimensional Evaluation of Interradicular Areas and Cortical Bone Thickness for Orthodontic Miniscrew Implant Placement Using Cone-beam Computed Tomography.

Authors:  Garadappagari Dharmadeep; Moode Kaladhar Naik; Yellampalli Muralidhar Reddy; Sreekanth Cheruluri; Kranthi Praveen Raj; Badepalli Reddeppa Reddy
Journal:  J Pharm Bioallied Sci       Date:  2020-08-28

5.  Comparative Evaluation of Primary Stability of Two Different Types of Orthodontic Mini-Implants.

Authors:  Jyotirmay Singh; Sanjay Kumar Singh; Abhinav Raj Gupta; Subhash Chandra Nayak; Ritesh Vatsa; Priyanka Priyadarshni
Journal:  J Pharm Bioallied Sci       Date:  2021-06-05

6.  Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque.

Authors:  Višnja Katić; Ervin Kamenar; David Blažević; Stjepan Spalj
Journal:  Korean J Orthod       Date:  2014-07-24       Impact factor: 1.372

7.  Quantification of pro-inflammatory cytokines and osteoclastogenesis markers in successful and failed orthodontic mini-implants.

Authors:  Marcela Cristina Damião Andrucioli; Mírian Aiko Nakane Matsumoto; Sandra Yasuyo Fukada; Maria Conceição Pereira Saraiva; Ana Zilda Nazar Bergamo; Fábio Lourenço Romano; Raquel Assed Bezerra da Silva; Lea Assed Bezerra da Silva; Paulo Nelson-Filho
Journal:  J Appl Oral Sci       Date:  2019-10-07       Impact factor: 2.698

8.  Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity.

Authors:  Hyun-Ju Oh; Jung-Yul Cha; Hyung-Seog Yu; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2018-08-08       Impact factor: 1.372

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.