| Literature DB >> 22164107 |
M Soledad García1, Joaquín A Ortuño, María Cuartero, Mustafa Salem Abuherba.
Abstract
The construction and characterization of a new ion-selective electrode for the determination of the antipsychotic ziprasidone in mixed solvents is presented. The electrode contains a plasticized polymeric membrane based on a ziprasidone-tetraphenylborate ion-exchanger. The influence of membrane composition on the electrode response towards ziprasidone in hydroalcoholic solutions was studied. The electrode displayed a stable response in a 2:3 (v/v) methanol/water medium from a ziprasidone concentration of 3 × 10(-6) M with a fast response time of less than 20 s. The electrode also showed good selectivity towards ziprasidone over common inorganic and organic compounds and several species with pharmacological activity. The electrode was successfully applied to the determination of ziprasidone in pharmaceuticals and human urine and serum.Entities:
Keywords: ion-selective electrode; mixed solvents; pharmaceuticals; serum; urine; ziprasidone
Mesh:
Substances:
Year: 2011 PMID: 22164107 PMCID: PMC3231489 DOI: 10.3390/s110908813
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1.Ziprasidone.
Composition of the membranes assayed.
| PVC | NPOE | DOS | ZPD-TPB | |
|---|---|---|---|---|
| A | 33.0 | 66.0 | 1.0 | |
| B | 33.0 | 66.0 | 1.0 | |
| C | 32.3 | 64.7 | 3.0 | |
Figure 1.Calibration graphs of ziprasidone obtained with membranes A, B and C.
Figure 2.Influence of the pH on the electrode potential for different ziprasidone concentrations.
Figure 3.Calibration graphs in different media. (A) 1:4 (v/v) methanol/water; (B) 2:3 (v/v) methanol/water; (C) 3:2 (v/v) methanol/water; and (D) 2:3 (v/v) ethanol/water.
Figure 4.Dynamic response of the electrode for ziprasidone concentrations of (1) 0 M; (2) 1.6 × 10−6; (3) 3.2 × 10−6 M; (4) 7.2 × 10−6 M; (5) 1.1 × 10−5 M; (6) 1.9 × 10−5 M; (7) 2.7 × 10−5 M; (8) 4.3 × 10−5 M; (9) 5.8 × 10−5 M; (10) 9.7 × 10−5 M; and (11) 1.6 × 10−4 M.
Response characteristics of the ziprasidone selective electrode.
| Range (M) | 1.6 × 10−6–1.6 × 10−4 |
| Linearity (M) | 2 × 10−5–8 × 10−4 |
| Slope (mV decade−1) ± RSD | 59.3 ± 1.8 |
| Limit of detection (M) ± RSD | 1.8 × 10−5 ± 2.1 × 10−6 |
| Accuracy | 99.38 ± 0.37 |
| Response time (s) | t95% ≤ 15 |
| Working pH range | 3.5–5.5 |
| Operational lifetime (days) | ≥ 40 |
mean of six calibrations.
ZPD concentration range of 1.6 × 10−6–1.6 × 10−4 M.
Recovery ± RSD (n = 10).
Determination of ziprasidone in pharmaceuticals.
| Zeldox capsules | 20.00 | 20.02 ± 0.54 | 0.10 | 5.86 | 25.82 | 99.3 ± 0.5 | −0.68 |
| 11.73 | 31.93 | 101.7 ± 4.1 | 1.70 | ||||
| 18.70 | 38.68 | 99.9 ± 3.5 | −0.11 | ||||
| Zeldox injectables | 20.00 | 20.39 ± 1.09 | 1.90 | 5.86 | 25.87 | 100.2 ± 0.7 | 0.17 |
| 11.73 | 31.80 | 100.6 ± 0.2 | 0.59 | ||||
| 18.70 | 38.66 | 99.8 ± 0.1 | −0.21 | ||||
ZPD mg/capsule or injectable.
Average of three experiments.
Mean ± RSD (n = 4).
Determination of ziprasidone in human urine and serum.
| Urine 1 | 2.80 | 2.70 | 96.4 ± 1.2 | −3.57 |
| Urine 2 | 4.70 | 4.73 | 100.6 ± 0.5 | 0.64 |
| Urine 3 | 8.30 | 8.08 | 97.4 ± 2.0 | −2.65 |
| Urine 4 | 12.0 | 12.3 | 102.5 ± 1.4 | 2.50 |
| Serum 1 | 0.90 | 0.93 | 103.3 ± 1.1 | 3.33 |
| Serum 2 | 2.80 | 2.79 | 99.6 ± 0.3 | −0.36 |
| Serum 3 | 6.50 | 6.49 | 99.8 ± 0.2 | −0.15 |
| Serum 4 | 15.6 | 15.88 | 101.8 ± 0.9 | 1.79 |
ZPD mg/L urine.
ZPD μg/mL serum.
Average of five experiments.