Literature DB >> 17723734

Potentiometric membrane sensor based on 6-(4-nitrophenyl)-2,4-diphenyl-3,5-diaza-bicyclo[3.1.0]hex-2-ene for detection of Sn(II) in real samples.

Majid Arvand1, A Majid Moghimi, Anoosheh Afshari, Nosratollah Mahmoodi.   

Abstract

A Sn2+ ion-selective electrode which was prepared with a polymeric membrane based on 6-(4-nitrophenyl)-2,4-diphenyl-3,5-diaza-bicyclo[3.1.0]hex-2-ene (NDDBH) as a ionophore. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, the amount of additive and concentration of internal solution on the potential response of Sn2+ sensor were investigated. The electrode exhibited a Nernstian slope of 28.8+/-1.1 mV/decade of Sn2+ over a concentration range of 1.0 x 10(-5) to 1.0 x 10(-1) M of Sn2+ in an acidic solution (pH 1). The limit of detection was 4.0 x 10(-6) M. The results show that this electrode can be used in ethanol media until 20% (v/v) concentration without interference. It can be used for more than 6 weeks without any considerable divergence in the potentials. The proposed membrane electrode revealed very good selectivity for Sn(II) ions over a wide variety of other cations and could be used in acidic media. The standard electrode potentials were determined at different temperatures and used to calculate the isothermal coefficient of the electrode. The stability constant (log K(s)) of the Sn(II)-ionophore complex was determined at 25 degrees C by potentiometric titration in mixed aqueous solution. It was used as indicator electrode in potentiometric determination of Sn(II) ion in real samples.

Entities:  

Year:  2006        PMID: 17723734     DOI: 10.1016/j.aca.2006.07.022

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  5 in total

1.  Rhodamine-based chemosensor for Sn2+ detection and its application in nanofibrous film and bioimaging.

Authors:  Yaqiong Kong; Mengmeng Wang; Wensheng Lu; Lei Li; Jing Li; Minmin Chen; Qian Wang; Guoxu Qin; Duojun Cao
Journal:  Anal Bioanal Chem       Date:  2022-01-20       Impact factor: 4.142

Review 2.  Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade.

Authors:  Farnoush Faridbod; Parviz Norouzi; Rassoul Dinarvand; Mohammad Reza Ganjali
Journal:  Sensors (Basel)       Date:  2008-04-03       Impact factor: 3.576

3.  Schiff's Bases and Crown Ethers as Supramolecular Sensing Materials in the Construction of Potentiometric Membrane Sensors.

Authors:  Farnoush Faridbod; Mohammad Reza Ganjali; Rassoul Dinarvand; Parviz Norouzi; Siavash Riahi
Journal:  Sensors (Basel)       Date:  2008-03-11       Impact factor: 3.576

4.  Use of a new ziprasidone-selective electrode in mixed solvents and its application in the analysis of pharmaceuticals and biological fluids.

Authors:  M Soledad García; Joaquín A Ortuño; María Cuartero; Mustafa Salem Abuherba
Journal:  Sensors (Basel)       Date:  2011-09-13       Impact factor: 3.576

5.  An ICT-based fluorescence enhancement probe for detection of Sn2+ in cancer cells.

Authors:  Xiangying Meng; Lai You; Siyuan Li; Qi Sun; Xiaogang Luo; Haifeng He; Jinglan Wang; Feng Zhao
Journal:  RSC Adv       Date:  2020-10-13       Impact factor: 4.036

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.