Literature DB >> 22162141

StarClose vascular closure system (VCS) is safe and effective in patients who ambulate early following successful femoral artery access closure--results from the RISE clinical trial.

M Nicholas Burke1, James Hermiller, Michael R Jaff.   

Abstract

OBJECTIVE: The RISE study was a prospective, multicenter, single-arm study evaluating the safety and efficacy of the StarClose Vascular Closure System (VCS) in the femoral artery in subjects who were ambulated early following percutaneous diagnostic coronary or peripheral catheterization procedures.
BACKGROUND: Previous studies have demonstrated that several vascular closure devices are able to safely decrease the amount of bedrest needed following angiography. To date, no device has been shown to be safe for immediate ambulation.
METHODS: Between April 2006 and November 2006, 315 patients undergoing a catheterization via the femoral artery were enrolled (intent-to-treat population, ITT). Of these, 171 subjects were not excluded by angiographic or clinical criteria and had a StarClose device placed to attain hemostasis. If hemostasis was immediately achieved, patients were ambulated within 20 min for 20 feet without assistance (per-protocol population, PP). Patients were followed for 30 days after the index procedure. The primary endpoint of the study was time to ambulation (TTA).
RESULTS: Immediate hemostasis was achieved in 156 patients (91.2%). The mean TTA in the PP was 8.29 min, median 5.92. There were no deaths or major vascular complications, and the rate of minor vascular complications was 1.9% (3/156).
CONCLUSION: The StarClose VCS device is both safe and effective allowing immediate ambulation of patients who have undergone catheterization via the femoral artery.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 22162141     DOI: 10.1002/ccd.23176

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  10 in total

1.  Safety and feasibility of a novel vascular closure device in neurointerventional procedures.

Authors:  Ammar Taha; Ellen K Walsh; Kathryn A Wright; Iftikhar Ahmed; Nucharin Supakul; Eric E Awwad; Juan G Tejada
Journal:  Interv Neuroradiol       Date:  2013-09-26       Impact factor: 1.610

2.  Prospective series of two hours supine rest after 4fr sheath-based diagnostic cerebral angiography: Outcomes, productivity and cost.

Authors:  Scott L Zuckerman; Ritwik Bhatia; Crystiana Tsujiara; Christopher B Baker; Alex Szafran; Deborah Cushing; Judy Aiken; Marilyn Tracy; J Mocco; Robert D Ecker
Journal:  Interv Neuroradiol       Date:  2015-02       Impact factor: 1.610

Review 3.  Access and hemostasis: femoral and popliteal approaches and closure devices-why, what, when, and how?

Authors:  Iacopo Barbetta; Jos C van den Berg
Journal:  Semin Intervent Radiol       Date:  2014-12       Impact factor: 1.513

4.  Accelerated ambulation after vascular access closure device.

Authors:  Daniel Brancheau; Sinan Sarsam; Mahmoud Assaad; Marcel Zughaib
Journal:  Ther Adv Cardiovasc Dis       Date:  2018-02-08

5.  [Arterial closure devices. What device for which clinical situation?].

Authors:  M Treitl; K M Eberhardt; D Maxien; B Behrends; M F Reiser
Journal:  Radiologe       Date:  2013-03       Impact factor: 0.635

6.  Femoral arterial closure using ProGlide® is more efficacious and cost-effective when ambulating early following cardiac catheterization.

Authors:  Aravind Sekhar; Brad S Sutton; Prafull Raheja; Amr Mohsen; Emily Anggelis; Chris N Anggelis; Matthew C Keith; Buddhadeb Dawn; Samantha Straton; Michael P Flaherty
Journal:  Int J Cardiol Heart Vasc       Date:  2016-10-11

7.  Vascular Closure Devices versus Manual Compression in Cardiac Interventional Procedures: Systematic Review and Meta-Analysis.

Authors:  Naidong Pang; Jia Gao; Binghang Zhang; Min Guo; Nan Zhang; Meng Sun; Rui Wang
Journal:  Cardiovasc Ther       Date:  2022-09-09       Impact factor: 3.368

8.  Central Pseudo-Aneurysm Formation Following Arterial Closure with a StarClose SE Device: When a StarClose Doesn't Completely Close.

Authors:  Sehrish Memon; Timothy C Ball
Journal:  Am J Case Rep       Date:  2016-03-30

9.  Safety and efficacy of the StarClose vascular closure system following 8-Fr sheath placement for intra-aortic balloon pump: a single-center analysis of 42 consecutive patients.

Authors:  Guang Chu; Wenyi Yang; Guobing Zhang; Zhi Zhang; Shaowen Liu; Baogui Sun; Fang Wang
Journal:  Med Princ Pract       Date:  2014-04-23       Impact factor: 1.927

10.  Flip-over of blood vessel intima caused by vascular closure device: A case report.

Authors:  Li-Xia Sun; Xue-Song Yang; Da-Wei Zhang; Bo Zhao; Lian-Lian Li; Qi Zhang; Qing-Zhi Hao
Journal:  World J Clin Cases       Date:  2022-03-06       Impact factor: 1.337

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.