Literature DB >> 22153951

Sagittal flexion of the femoral component affects flexion gap and sizing in total knee arthroplasty.

Tadashi Tsukeoka1, Tae Hyun Lee.   

Abstract

The purpose of this study was to determine how much sagittal rotation of the femoral component affects the flexion gap and femoral component sizing using a computer-simulation technique. The study comprised 25 knees scheduled for total knee arthroplasty (TKA). The femoral component was positioned at -2°, 0°, 2°, 4°, or 6° of flexion to the anterior femoral cortex, and the resected portion of the posterior medial femoral condyle was measured for 3 total knee systems. The amount of the resected bone of the posterior medial condyle decreased approximately 1 mm for every 2° of additional flexion in all TKA systems. Intentional sagittal flexion of the femoral component by several degrees during TKA can be a useful downsizing technique for the femoral component without excessively increasing the flexion gap.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22153951     DOI: 10.1016/j.arth.2011.10.015

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  17 in total

1.  Morphological evaluation of the sagittal plane femoral load-bearing surface in computer-simulated virtual total knee arthroplasty implantation at different flexion angles.

Authors:  Shichang Chen; Yiming Zeng; Mengning Yan; Bing Yue; Jun Zhang; You Wang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-25       Impact factor: 4.342

2.  Appropriate sagittal femoral component alignment cannot be ensured by intramedullary alignment rods.

Authors:  Günther Maderbacher; Jens Schaumburger; Clemens Baier; Florian Zeman; Hans-Robert Springorum; Anne-Maria Birkenbach; Joachim Grifka; Armin Keshmiri
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-02-15       Impact factor: 4.342

3.  Effect of soft tissue laxity of the knee joint on limb alignment correction in open-wedge high tibial osteotomy.

Authors:  Dae-Hee Lee; Sung-Chul Park; Hyung-Joon Park; Seung-Beom Han
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-07-08       Impact factor: 4.342

4.  [Ligament-controlled positioning of the knee prosthesis components].

Authors:  K-H Widmer; A Zich
Journal:  Orthopade       Date:  2015-04       Impact factor: 1.087

5.  Influence of intentional femoral component flexion in navigated TKA on gap balance and sagittal anatomy.

Authors:  J Roßkopf; P K Singh; P Wolf; M Strauch; H Graichen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-10-26       Impact factor: 4.342

6.  Effect of Femoral Component Flexion Implantation on the Mediolateral Bone-prosthetic Fit in Total Knee Arthroplasty.

Authors:  Shi-Chang Chen; Yi-Ming Zeng; Meng-Ning Yan; Bing Yue; Jun Zhang; You Wang
Journal:  Orthop Surg       Date:  2017-02       Impact factor: 2.071

7.  Bony impingement depends on the bone morphology of the hip after total hip arthroplasty.

Authors:  Takeshi Shoji; Yuji Yasunaga; Takuma Yamasaki; Ryo Mori; Michio Hamanishi; Mitsuo Ochi
Journal:  Int Orthop       Date:  2013-07-17       Impact factor: 3.075

8.  What clinical characteristics and radiographic parameters are associated with patellofemoral instability after kinematically aligned total knee arthroplasty?

Authors:  Alexander J Nedopil; Stephen M Howell; Maury L Hull
Journal:  Int Orthop       Date:  2016-09-12       Impact factor: 3.075

9.  Femoral sizing in total knee arthroplasty is rotation dependant.

Authors:  Angelique Koninckx; Arnaud Deltour; Emmanuel Thienpont
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-10-09       Impact factor: 4.342

10.  The medial proximal tibial angle accurately corrects the limb alignment in open-wedge high tibial osteotomy.

Authors:  Mitsuaki Kubota; Ryuichi Ohno; Taisuke Sato; Junichiro Yamaguchi; Haruka Kaneko; Kazuo Kaneko; Muneaki Ishijima
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-25       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.