Literature DB >> 22145709

Particulate matter concentrations in residences: an intervention study evaluating stand-alone filters and air conditioners.

S Batterman1, L Du, G Mentz, B Mukherjee, E Parker, C Godwin, J-Y Chin, A O'Toole, T Robins, Z Rowe, T Lewis.   

Abstract

UNLABELLED: This study, a randomized controlled trial, evaluated the effectiveness of free-standing air filters and window air conditioners (ACs) in 126 low-income households of children with asthma. Households were randomized into a control group, a group receiving a free-standing HEPA filter placed in the child's sleeping area, and a group receiving the filter and a window-mounted AC. Indoor air quality (IAQ) was monitored for week-long periods over three to four seasons. High concentrations of particulate matter (PM) and carbon dioxide were frequently seen. When IAQ was monitored, filters reduced PM levels in the child's bedroom by an average of 50%. Filter use varied greatly among households and declined over time, for example, during weeks when pollutants were monitored, filter use was initially high, averaging 84±27%, but dropped to 63±33% in subsequent seasons. In months when households were not visited, use averaged only 34±30%. Filter effectiveness did not vary in homes with central or room ACs. The study shows that measurements over multiple seasons are needed to characterize air quality and filter performance. The effectiveness of interventions using free-standing air filters depends on occupant behavior, and strategies to ensure filter use should be an integral part of interventions. PRACTICAL IMPLICATIONS: Environmental tobacco smoke (ETS) increased particulate matter (PM) levels by about 14 μg/m3 and was often detected using ETS-specific tracers despite restrictions on smoking in the house as reported on questionnaires administered to caregivers. PM concentrations depended on season, filter usage, relative humidity, air exchange ratios, number of children, outdoor PM levels, sweeping/dusting, and presence of a central air conditioner (AC). Free-standing air filters can be an effective intervention that provides substantial reductions in PM concentrations if the filters are used. However, filter use was variable across the study population and declined over the study duration, and thus strategies are needed to encourage and maintain use of filters. The variability in filter use suggests that exposure misclassification is a potential problem in intervention studies using filters. The installation of a room AC in the bedroom, intended to limit air exchange ratios, along with an air filter, did not lower PM levels more than the filter alone.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22145709      PMCID: PMC4233141          DOI: 10.1111/j.1600-0668.2011.00761.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  32 in total

1.  Low-flow active and passive sampling of VOCs using thermal desorption tubes: theory and application at an offset printing facility.

Authors:  Stuart Batterman; Tricia Metts; Pentti Kalliokoski; Emily Barnett
Journal:  J Environ Monit       Date:  2002-06

2.  Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems.

Authors:  David L Macintosh; Theodore A Myatt; Jerry F Ludwig; Brian J Baker; Helen H Suh; John D Spengler
Journal:  J Air Waste Manag Assoc       Date:  2008-11       Impact factor: 2.235

3.  Seasonal and diurnal variability in airborne mold from an indoor residential environment in northern New York.

Authors:  Ryan LeBouf; Liesel Yesse; Alan Rossner
Journal:  J Air Waste Manag Assoc       Date:  2008-05       Impact factor: 2.235

4.  Indoor exposures to air pollutants and allergens in the homes of asthmatic children in inner-city Baltimore.

Authors:  Patrick N Breysse; Timothy J Buckley; D'Ann Williams; Christopher M Beck; Seong-Joon Jo; Barry Merriman; Sukon Kanchanaraksa; Lee J Swartz; Karen A Callahan; Arlene M Butz; Cynthia S Rand; Gregory B Diette; Jerry A Krishnan; Adrian M Moseley; Jean Curtin-Brosnan; Nowella B Durkin; Peyton A Eggleston
Journal:  Environ Res       Date:  2005-06       Impact factor: 6.498

5.  Relationships of Indoor, Outdoor, and Personal Air (RIOPA). Part I. Collection methods and descriptive analyses.

Authors:  Clifford P Weisel; Junfeng Zhang; Barbara J Turpin; Maria T Morandi; Steven Colome; Thomas H Stock; Dalia M Spektor; Leo Korn; Arthur M Winer; Jaymin Kwon; Qing Yu Meng; Lin Zhang; Robert Harrington; Weili Liu; Adam Reff; Jong Hoon Lee; Shahnaz Alimokhtari; Kishan Mohan; Derek Shendell; Jennifer Jones; L Farrar; Slivia Maberti; Tina Fan
Journal:  Res Rep Health Eff Inst       Date:  2005-11

6.  Identification of gaps in the diagnosis and treatment of childhood asthma using a community-based participatory research approach.

Authors:  Toby C Lewis; Thomas G Robins; Christine L M Joseph; Edith A Parker; Barbara A Israel; Zachary Rowe; Katherine K Edgren; Maria A Salinas; Michael E Martinez; Randall W Brown
Journal:  J Urban Health       Date:  2004-09       Impact factor: 3.671

7.  The effects of season, climate, and air-conditioning on the prevalence of Dermatophagoides mite allergens in household dust.

Authors:  T J Lintner; K A Brame
Journal:  J Allergy Clin Immunol       Date:  1993-04       Impact factor: 10.793

8.  Simultaneous measurement of ventilation using tracer gas techniques and VOC concentrations in homes, garages and vehicles.

Authors:  Stuart Batterman; Chunrong Jia; Gina Hatzivasilis; Chris Godwin
Journal:  J Environ Monit       Date:  2006-01-18

9.  Characterization of indoor particle sources: A study conducted in the metropolitan Boston area.

Authors:  E Abt; H H Suh; G Allen; P Koutrakis
Journal:  Environ Health Perspect       Date:  2000-01       Impact factor: 9.031

10.  Home and allergic characteristics of children with asthma in seven U.S. urban communities and design of an environmental intervention: the Inner-City Asthma Study.

Authors:  Ellen F Crain; Michelle Walter; George T O'Connor; Herman Mitchell; Rebecca S Gruchalla; Meyer Kattan; George S Malindzak; Paul Enright; Richard Evans; Wayne Morgan; James W Stout
Journal:  Environ Health Perspect       Date:  2002-09       Impact factor: 9.031

View more
  29 in total

1.  Concentrations and risks of p-dichlorobenzene in indoor and outdoor air.

Authors:  J-Y Chin; C Godwin; C Jia; T Robins; T Lewis; E Parker; P Max; S Batterman
Journal:  Indoor Air       Date:  2012-07-18       Impact factor: 5.770

2.  The feasibility of an air purifier and secondhand smoke education intervention in homes of inner city pregnant women and infants living with a smoker.

Authors:  Jessica L Rice; Emily Brigham; Rebecca Dineen; Sadiya Muqueeth; Gena O'Keefe; Stephanie Regenold; Kirsten Koehler; Ana Rule; Meredith McCormack; Nadia N Hansel; Gregory B Diette
Journal:  Environ Res       Date:  2017-10-29       Impact factor: 6.498

3.  Effects of Home Particulate Air Filtration on Blood Pressure: A Systematic Review.

Authors:  Dalia Walzer; Terry Gordon; Lorna Thorpe; George Thurston; Yuhe Xia; Hua Zhong; Timothy R Roberts; Judith S Hochman; Jonathan D Newman
Journal:  Hypertension       Date:  2020-06-01       Impact factor: 10.190

4.  In vitro inhalation/ingestion bioaccessibility, health risks, and source appointment of airborne particle-bound elements trapped in room air conditioner filters.

Authors:  Xin Hu; Xuebin Xu; Zhuhong Ding; Yijun Chen; Hong-Zhen Lian
Journal:  Environ Sci Pollut Res Int       Date:  2018-07-03       Impact factor: 4.223

5.  In-home air filtration for improving cardiovascular health: lessons from a CBPR study in public housing.

Authors:  Doug Brugge; Ellin Reisner; Luz T Padró-Martínez; Wig Zamore; Emmanuel Owusu; John L Durant
Journal:  Prog Community Health Partnersh       Date:  2013

6.  Effectiveness of a portable air cleaner in removing aerosol particles in homes close to highways.

Authors:  Jennie Cox; Kelechi Isiugo; Patrick Ryan; Sergey A Grinshpun; Michael Yermakov; Colleen Desmond; Roman Jandarov; Stephen Vesper; James Ross; Steven Chillrud; Karen Dannemiller; Tiina Reponen
Journal:  Indoor Air       Date:  2018-09-17       Impact factor: 5.770

7.  Developing Community-Level Policy and Practice to Reduce Traffic-Related Air Pollution Exposure.

Authors:  Doug Brugge; Allison P Patton; Alex Bob; Ellin Reisner; Lydia Lowe; Oliver-John M Bright; John L Durant; Jim Newman; Wig Zamore
Journal:  Environ Justice       Date:  2015-06-15

8.  Levels and sources of volatile organic compounds in homes of children with asthma.

Authors:  J-Y Chin; C Godwin; E Parker; T Robins; T Lewis; P Harbin; S Batterman
Journal:  Indoor Air       Date:  2014-01-13       Impact factor: 5.770

9.  Use of Free-standing Filters in an Asthma Intervention Study.

Authors:  Stuart Batterman; Liuliu Du; Edith Parker; Thomas Robins; Toby Lewis; Bhramar Mukherjee; Erminia Ramirez; Zachary Rowe; Wilma Brakefield-Caldwell
Journal:  Air Qual Atmos Health       Date:  2013-12       Impact factor: 3.763

10.  Particulate matter in the indoor and outdoor air of a gymnasium and a fronton.

Authors:  Célia Alves; Ana I Calvo; Liliana Marques; Amaya Castro; Teresa Nunes; Esther Coz; Roberto Fraile
Journal:  Environ Sci Pollut Res Int       Date:  2014-06-18       Impact factor: 4.223

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.