Radiation dose to neonates undergoing X-ray imaging in special care baby units in Iran.

Reza Faghihi1, Simin Mehdizadeh, Sedigheh Sina, Fatemeh N Alizadeh, Banafsheh Zeinali, Gholam Reza Kamyab, Sadaf Aghevlian, Hossein Khorramdel, Imen Namazi, Mandana Heirani, Meisam Moshkriz, Hojjat Mahani, Mohsen Sharifzadeh.   

Abstract

Radiographic imaging has a significant role in the timely diagnosis of the diseases of neonates in intensive care units. The estimation of the dose received by the infants undergoing radiographic examination is of great importance, due to greater more radiosensitivity and longer life expectancy of the neonates and premature babies. In this study, the values of entrance skin dose (ESD), dose area products (DAPs), energy imparted (EI), whole-body dose, effective dose and risk of childhood cancer were estimated using three methods including direct method [using thermoluminescence dosimetry (TLD) chips], indirect method (using tube output) and Monte Carlo (MC) method (using MCNP4C code). In the first step, the ESD of the neonates was directly measured using TLD-100 chips. Fifty neonates, mostly premature, with different weights and gestational ages in five hospitals mostly suffering from respiratory distress syndrome and pneumonia were involved in this study. In the second step, the values of ESD to neonates were indirectly obtained from the tube output in different imaging techniques. The imaging room, incubator, neonates and other components were then simulated in order to obtain the ESD values using the MCNP4C code. Finally, the values of ESD assessed by the three methods were used for calculation of DAP, EI, whole-body dose, effective dose and risk of childhood cancer. The results indicate that the mean ESD per radiograph estimated by the direct, indirect and MC methods are 56.6±4.1, 50.1±3.1 and 54.5±3.3 μGy, respectively. The mean risk of childhood cancer estimated in this study varied between 4.21×10(-7) and 2.72×10(-6).

Entities:  

Mesh:

Year:  2011        PMID: 22128357     DOI: 10.1093/rpd/ncr373

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Measurement of Entrance Skin Dose and the Dose Received by Different Organs in Panoramic Dental Imaging.

Authors:  Ahmadi A; Negarestani A; Sina S; Sarshough S
Journal:  J Biomed Phys Eng       Date:  2020-10-01

2.  A New Approach for Heterogeneity Corrections for Cs-137 Brachytherapy Sources.

Authors:  S Sina; R Faghihi; A S Meigooni
Journal:  J Biomed Phys Eng       Date:  2015-06-01

3.  Investigation of the entrance surface dose and dose to different organs in lumbar spine imaging.

Authors:  S Sina; B Zeinali; M Karimipoorfard; F Lotfalizadeh; M Sadeghi; E Zamani; R Faghihi
Journal:  J Biomed Phys Eng       Date:  2014-12-15

4.  Investigation of LiF, Mg and Ti (TLD-100) Reproducibility.

Authors:  M Sadeghi; S Sina; R Faghihi
Journal:  J Biomed Phys Eng       Date:  2015-12-01

5.  Radiation dose to newborns in neonatal intensive care units.

Authors:  Mohammad Taghi Bahreyni Toossi; Malakeh Malekzadeh
Journal:  Iran J Radiol       Date:  2012-09-17       Impact factor: 0.212

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.