Literature DB >> 22126713

Functional forms for photon spectra of clinical linacs.

E S M Ali1, D W O Rogers.   

Abstract

Specifying photon spectra of clinical linacs using a functional form is useful for many applications, including virtual source modelling and spectral unfolding from dosimetric measurements such as transmission data or depth-dose curves. In this study, 11 functional forms from the literature are compiled and quantitatively compared. A new function is proposed which offers improvements over existing ones. The proposed function is simple, physics-based and has four free parameters, one of which is the mean incident electron kinetic energy. A comprehensive benchmark set of validated, high-precision Monte Carlo spectra is generated and used to evaluate the strengths and limitations of different functions. The benchmark set has 65 spectra (3.5-30 MV) from Varian, Elekta, Siemens, Tomotherapy, Cyberknife and research linacs. The set includes spectra on- and off-axis from linacs with and without a flattening filter, and in treatment and imaging modes. The proposed function gives the lowest spectral deviations among all functions. It reproduces the energy fluence values in each bin for the benchmark set with a normalized root-mean-square deviation of 1.7%. The mean incident electron kinetic energy, maximum photon energy, most-probable energy and average energy are reproduced, on average, within 1.4%, 4.3%, 3.9% and 0.6% of their true values, respectively. The proposed function is well behaved when used for spectral unfolding from dosimetric data. The contribution of the 511 keV annihilation peak and the energy spread of the incident electron beam can be added as additional free parameters.

Mesh:

Year:  2011        PMID: 22126713     DOI: 10.1088/0031-9155/57/1/31

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Effect of age-dependent bone electron density on the calculated dose distribution from kilovoltage and megavoltage photon and electron radiotherapy in paediatric MRI-only treatment planning.

Authors:  B Zeinali-Rafsanjani; R Faghihi; M A Mosleh-Shirazi; M Saeedi-Moghadam; R Jalli; S Sina
Journal:  Br J Radiol       Date:  2017-11-09       Impact factor: 3.039

2.  Physical density estimations of single- and dual-energy CT using material-based forward projection algorithm: a simulation study.

Authors:  Kai-Wen Li; Daiyu Fujiwara; Akihiro Haga; Huisheng Liu; Li-Sheng Geng
Journal:  Br J Radiol       Date:  2021-09-29       Impact factor: 3.039

3.  An Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams.

Authors:  F Seif; M J Tahmasebi-Birgani; M R Bayatiani
Journal:  J Biomed Phys Eng       Date:  2017-09-01

4.  A virtual source model for Monte Carlo simulation of helical tomotherapy.

Authors:  Jiankui Yuan; Yi Rong; Quan Chen
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.