| Literature DB >> 29082214 |
F Seif1, M J Tahmasebi-Birgani2, M R Bayatiani1.
Abstract
BACKGROUND: In this study, a method for linear attenuation coefficient calculation was introduced.Entities:
Keywords: Energy Spectral; Linear Attenuation Coefficient ; Cerrobend
Year: 2017 PMID: 29082214 PMCID: PMC5654129
Source DB: PubMed Journal: J Biomed Phys Eng ISSN: 2251-7200
Figure1schematic diagram of scatter calculation geometry
Figure2Farmer Ionization chamber (FC65)
Figure3Dose 1 Electrometer
Figure4Varian Linac and water phantom
Reading ratio and calculated linear attenuation coefficient for different Cerrobend thickness
| Cerrobend thickness (cm±0.01) | 6×6 cm2 | 8×8 cm2 | 10×10 cm2 | 12×12 cm2 | 14×14 cm2 | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| r | mu | r | mu | R | mu | r | mu | r | mu | |
| 1.35 | 48.5 | 0.514 | 48.8 | 0.491 | 49 | 0.472 | 49.3 | 0.447 | 51.2 | 0.395 |
| 2.7 | 26 | 0.477 | 26.3 | 0.457 | 27 | 0.427 | 26.9 | 0.405 | 28 | 0.364 |
| 4.05 | 14.6 | 0.453 | 14.8 | 0.433 | 15 | 0.409 | 15.3 | 0.378 | 16 | 0.337 |
| 5.4 | 8.3 | 0.439 | 8.4 | 0.419 | 8.6 | 0.392 | 8.8 | 0.359 | 9.2 | 0.315 |
| 6.75 | 4.7 | 0.431 | 4.8 | 0.409 | 4.9 | 0.382 | 5 | 0.346 | 5.3 | 0.293 |
| 8.1 | 2.7 | 0.423 | 2.8 | 0.4 | 2.9 | 0.369 | 2.9 | 0.331 | 3.1 | 0.28 |
| 9.45 | 1.3 | 0.42 | 1.4 | 0.4 | 1.4 | 0.368 | 1.5 | 0.33 | 1.6 | 0.27 |
Reading ratio and calculated linear attenuation coefficient for different Mercury thickness
| Mercury thickness (cm±0.01) | 6×6 cm2 | 8×8 cm2 | 10×10 cm2 | 12×12 cm2 | 14×14 cm2 | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| R | mu | r | mu | R | mu | R | mu | r | Mu | |
| 0.65 | 58.6 | 0.792 | 59 | 0.759 | 59 | 0.733 | 58.8 | 0.709 | 60.9 | 0.623 |
| 1 | 46.9 | 0.726 | 47 | 0.702 | 47.5 | 0.665 | 47.8 | 0.628 | 49.5 | 0.56 |
| 1.5 | 34 | 0.688 | 34.6 | 0.654 | 35 | 0.619 | 35.1 | 0.585 | 36.4 | 0.525 |
| 2 | 24.7 | 0.668 | 25 | 0.639 | 25.3 | 0.605 | 25.5 | 0.567 | 26.6 | 0.508 |
| 3 | 13.6 | 0.634 | 13.8 | 0.605 | 14 | 0.569 | 14.2 | 0.527 | 14.9 | 0.467 |
| 4 | 7 | 0.633 | 7.5 | 0.591 | 7.7 | 0.551 | 7.9 | 0.503 | 8.3 | 0.437 |
| 5 | 4 | 0.612 | 4.3 | 0.571 | 4.4 | 0.531 | 4.5 | 0.478 | 4.8 | 0.397 |
| 6 | 2 | 0.619 | 2.4 | 0.562 | 2.5 | 0.516 | 2.6 | 0.452 | 2.7 | 0.38 |
Figure5Linear attenuation coefficient values v.s mercury attenuator thicknesses for different field sizes.
Figure6linear attenuation coefficient for different thickness of mercury attenuator and field sizes.