Literature DB >> 22107994

Reduced-count myocardial perfusion SPECT with resolution recovery.

Ian S Armstrong1, Parthiban Arumugam, Jackie M James, Christine M Tonge, Richard S Lawson.   

Abstract

AIM: The aim of this study was to determine whether resolution recovery (RR) iterative reconstruction algorithms can consistently produce diagnostic quality myocardial perfusion SPECT images for the patient population routinely scanned in this department. Reduced-count data were compared with full-count data without RR according to our established protocol. The desired outcome would be to implement the software to allow a reduction in the administered activity for routine myocardial SPECT.
METHODS: Half-count SPECT data were derived from full-count datasets for 53 stress and rest routine myocardial SPECT scans on a GE Infinia camera. Full-count data were reconstructed using standard non-RR ordered subset expectation maximization reconstruction, whereas half-count data were reconstructed using Evolution RR software. Myocardial functional values, image quality and report outcomes of the full-count and half-count reports were compared. Sequential full-time and half-time myocardial SPECT acquisitions were performed for 15 stress and rest studies on a Siemens c.cam dedicated cardiac camera. Half-count data were reconstructed using Siemens Flash 3D RR.
RESULTS: No degradation in image quality was found when comparing full-count and half-count studies from the Infinia. Ten percent of the half-count studies from the c.cam were considered slightly worse than full-count data. Statistically significant differences in some full-count versus half-count functional values were found but the actual mean differences were not considered clinically significant. No difference was found for 44 out of 53 full-count versus half-count reports, a minor difference for seven out of 53 and a significant difference in two cases.
CONCLUSION: RR was found to produce diagnostic image quality for nearly all scans, but it was felt that a reduction of 50% from our standard protocol was too great. A proposed reduction of 33% administered activity was considered acceptable to produce consistently adequate diagnostic images for both manufacturers.

Entities:  

Mesh:

Year:  2012        PMID: 22107994     DOI: 10.1097/MNM.0b013e32834e10d5

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  5 in total

1.  Dependence of left ventricular functional parameters on image acquisition time in cardiac-gated myocardial perfusion SPECT.

Authors:  Matti J Kortelainen; Tuomas M Koivumäki; Marko J Vauhkonen; Mikko A Hakulinen
Journal:  J Nucl Cardiol       Date:  2015-06-06       Impact factor: 5.952

2.  Simulating dose reduction for myocardial perfusion SPECT using a Poisson resampling method.

Authors:  Il-Hyun Kim; Su Jin Lee; Young-Sil An; So-Yeon Choi; Joon-Kee Yoon
Journal:  Nucl Med Mol Imaging       Date:  2021-08-13

3.  Effects of acquisition time and reconstruction algorithm on image quality, quantitative parameters, and clinical interpretation of myocardial perfusion imaging.

Authors:  Lotte H Enevoldsen; Changez A K Menashi; Ulrik B Andersen; Lars T Jensen; Otto M Henriksen
Journal:  J Nucl Cardiol       Date:  2013-08-21       Impact factor: 5.952

4.  Evaluation of general-purpose collimators against high-resolution collimators with resolution recovery with a view to reducing radiation dose in myocardial perfusion SPECT: A preliminary phantom study.

Authors:  Ian S Armstrong; Kimberley J Saint; Christine M Tonge; Parthiban Arumugam
Journal:  J Nucl Cardiol       Date:  2016-01-25       Impact factor: 5.952

5.  Technical note: Partitioning of gated single photon emission computed tomography raw data for protocols optimization.

Authors:  Cleiton Cavalcante Queiroz; Marcos Antonio Dorea Machado; Antonio Augusto Brito Ximenes; Andre Gustavo Silva Pino; Eduardo Martins Netto
Journal:  J Appl Clin Med Phys       Date:  2021-12-17       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.