Dependence of left ventricular functional parameters on image acquisition time in cardiac-gated myocardial perfusion SPECT.

Matti J Kortelainen1, Tuomas M Koivumäki, Marko J Vauhkonen, Mikko A Hakulinen.   

Abstract

BACKGROUND: Reduction of image acquisition time in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) examinations has been considered. However, association between left ventricular (LV) functional parameters and acquisition time is unclear.
METHODS: Twenty-four patients referred to one-day stress/rest SPECT MPI examinations were imaged at rest with dual-headed gamma camera. List-mode emission data were processed into sets of cardiac-gated images corresponding to different acquisition times: 20%, 30%, 40%, 50%, 60%, 80%, and 100% of total acquisition time (30 seconds per projection). Image quality was quantitatively evaluated by computing contrast-to-noise ratio. LV volumes, wall motion, wall thickening, and mechanical dyssynchrony were quantified with automatic clinical software (QGS; Cedars-Sinai Medical Center).
RESULTS: A significant negative dependence was found between phase analysis parameter values and image acquisition time. Differences in LV volume parameters were small but statistically significant at relative acquisition times of less than 50%. LV wall motion and wall thickening were found to be robust to the increase of noise.
CONCLUSIONS: Image acquisition time of gated SPECT MPI examination can be reduced to 15 seconds per projection without significantly affecting LV volumes, wall motion, or wall thickening. However, reduction of acquisition time has a significant effect on phase analysis results.

Entities:  

Mesh:

Year:  2015        PMID: 26048265     DOI: 10.1007/s12350-015-0178-4

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  29 in total

1.  Reduced-count myocardial perfusion SPECT with resolution recovery.

Authors:  Ian S Armstrong; Parthiban Arumugam; Jackie M James; Christine M Tonge; Richard S Lawson
Journal:  Nucl Med Commun       Date:  2012-02       Impact factor: 1.690

2.  Procedure guideline for myocardial perfusion imaging 3.3.

Authors:  H William Strauss; D Douglas Miller; Mark D Wittry; Manuel D Cerqueira; Ernest V Garcia; Abdulmassi S Iskandrian; Heinrich R Schelbert; Frans J Wackers; Helena R Balon; Otto Lang; Josef Machac
Journal:  J Nucl Med Technol       Date:  2008-08-14

3.  Acceleration of Monte Carlo-based scatter compensation for cardiac SPECT.

Authors:  A Sohlberg; H Watabe; H Iida
Journal:  Phys Med Biol       Date:  2008-06-23       Impact factor: 3.609

4.  On the importance of image gating for the assay of left ventricular mechanical dyssynchrony using SPECT.

Authors:  Daniel R Ludwig; Mati Friehling; David Schwartzman; Samir Saba; William P Follansbee; Prem Soman
Journal:  J Nucl Med       Date:  2012-11-09       Impact factor: 10.057

5.  Left-ventricular systolic and diastolic dyssynchrony as assessed by multi-harmonic phase analysis of gated SPECT myocardial perfusion imaging in patients with end-stage renal disease and normal LVEF.

Authors:  Ji Chen; Andreas P Kalogeropoulos; Liudmila Verdes; Javed Butler; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2011-01-13       Impact factor: 5.952

6.  Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" filtered backprojection.

Authors:  E Gordon DePuey; Ramesh Gadiraju; John Clark; Linda Thompson; Frank Anstett; Shuli C Shwartz
Journal:  J Nucl Cardiol       Date:  2008-04-24       Impact factor: 5.952

7.  Half-time SPECT myocardial perfusion imaging with attenuation correction.

Authors:  Iftikhar Ali; Terrence D Ruddy; Abdulaziz Almgrahi; Frank G Anstett; R Glenn Wells
Journal:  J Nucl Med       Date:  2009-03-16       Impact factor: 10.057

8.  Automatic global and regional phase analysis from gated myocardial perfusion SPECT imaging: application to the characterization of ventricular contraction in patients with left bundle branch block.

Authors:  Serge D Van Kriekinge; Hidetaka Nishina; Muneo Ohba; Daniel S Berman; Guido Germano
Journal:  J Nucl Med       Date:  2008-10-16       Impact factor: 10.057

9.  Compared performance of high-sensitivity cameras dedicated to myocardial perfusion SPECT: a comprehensive analysis of phantom and human images.

Authors:  Laetitia Imbert; Sylvain Poussier; Philippe R Franken; Bernard Songy; Antoine Verger; Olivier Morel; Didier Wolf; Alain Noel; Gilles Karcher; Pierre-Yves Marie
Journal:  J Nucl Med       Date:  2012-11-08       Impact factor: 10.057

10.  Ventricular dyssynchrony assessed by gated myocardial perfusion SPECT using a geometrical approach: a feasibility study.

Authors:  Berlinda J van der Veen; Imad Al Younis; Nina Ajmone-Marsan; Jos J M Westenberg; Jeroen J Bax; Marcel P M Stokkel; Albert de Roos
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-11-24       Impact factor: 9.236

View more
  2 in total

1.  How much shorter is better? Investigating image acquisition time reduction on left ventricular phase analysis for cardiac dyssynchrony.

Authors:  John O Prior
Journal:  J Nucl Cardiol       Date:  2015-06-13       Impact factor: 5.952

2.  Respiratory motion reduction with a dual gating approach in myocardial perfusion SPECT: Effect on left ventricular functional parameters.

Authors:  Matti J Kortelainen; Tuomas M Koivumäki; Marko J Vauhkonen; Marja K Hedman; Satu T J Kärkkäinen; Juanita Niño Quintero; Mikko A Hakulinen
Journal:  J Nucl Cardiol       Date:  2017-03-16       Impact factor: 5.952

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.