Literature DB >> 34721717

Simulating dose reduction for myocardial perfusion SPECT using a Poisson resampling method.

Il-Hyun Kim1, Su Jin Lee1, Young-Sil An1, So-Yeon Choi2, Joon-Kee Yoon1.   

Abstract

PURPOSE: The purpose of this study was to determine the lowest Tl-201 dose that does not reduce the image quality of myocardial perfusion SPECT (MPS) by Poisson resampling simulation.
METHODS: One hundred and twelve consecutive MPS data from patients with suspected or known coronary artery disease were collected retrospectively. Stress and rest MPS data were resampled using the Poisson method with 33%, 50%, 67%, and 100% count settings. Two nuclear medicine physicians assessed the image quality of reconstructed data visually by giving grades from - 2 to + 2. The summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) were obtained on the workstation. Image quality grades and semi-quantitative scores were then compared among these resampled images.
RESULTS: The proportions of "adequate" image quality were 0.48, 0.75, 0.92, and 0.96 for the groups of images with 33%, 50%, 67%, and 100% data, respectively. The quality of the resampled images was significantly degraded at 50% and 33% count settings, while the image quality was not different between 67 and 100% count settings. We also found that high body mass index further decreased image quality at 33% count setting. Among the semi-quantitative parameters, SSS and SRS showed a tendency to increase with a decline in count.
CONCLUSION: Based on the simulation results, Tl-201 dose for MPS can be reduced to 74 MBq without significant loss of image quality. However, the SSS and SRS can be changed significantly, and it needs to be further verified under the different conditions. © Korean Society of Nuclear Medicine 2021.

Entities:  

Keywords:  Myocardial perfusion SPECT; Poisson resampling; Radiation dose; Thallium-201

Year:  2021        PMID: 34721717      PMCID: PMC8517053          DOI: 10.1007/s13139-021-00710-w

Source DB:  PubMed          Journal:  Nucl Med Mol Imaging        ISSN: 1869-3474


  23 in total

1.  Reduced-count myocardial perfusion SPECT with resolution recovery.

Authors:  Ian S Armstrong; Parthiban Arumugam; Jackie M James; Christine M Tonge; Richard S Lawson
Journal:  Nucl Med Commun       Date:  2012-02       Impact factor: 1.690

2.  Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies.

Authors:  Salvador Borges-Neto; Robert A Pagnanelli; Linda K Shaw; Emily Honeycutt; Shuli C Shwartz; George L Adams; Ralph Edward Coleman
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

3.  Procedure guideline for myocardial perfusion imaging 3.3.

Authors:  H William Strauss; D Douglas Miller; Mark D Wittry; Manuel D Cerqueira; Ernest V Garcia; Abdulmassi S Iskandrian; Heinrich R Schelbert; Frans J Wackers; Helena R Balon; Otto Lang; Josef Machac
Journal:  J Nucl Med Technol       Date:  2008-08-14

4.  Clinical evaluation of reducing acquisition time on single-photon emission computed tomography image quality using proprietary resolution recovery software.

Authors:  Matthew D Aldridge; Wendy W Waddington; John C Dickson; Vineet Prakash; Peter J Ell; Jamshed B Bomanji
Journal:  Nucl Med Commun       Date:  2013-11       Impact factor: 1.690

5.  Optimal thallium-201 dose in cadmium-zinc-telluride SPECT myocardial perfusion imaging.

Authors:  Masaru Ishihara; Yasuyo Taniguchi; Masahisa Onoguchi; Takayuki Shibutani
Journal:  J Nucl Cardiol       Date:  2016-12-22       Impact factor: 5.952

6.  Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" filtered backprojection.

Authors:  E Gordon DePuey; Ramesh Gadiraju; John Clark; Linda Thompson; Frank Anstett; Shuli C Shwartz
Journal:  J Nucl Cardiol       Date:  2008-04-24       Impact factor: 5.952

7.  Incremental prognostic value of myocardial perfusion imaging in patients referred to stress single-photon emission computed tomography with renal dysfunction.

Authors:  Mouaz H Al-Mallah; Rory Hachamovitch; Sharmila Dorbala; Marcelo F Di Carli
Journal:  Circ Cardiovasc Imaging       Date:  2009-09-08       Impact factor: 7.792

8.  A multicenter evaluation of a new post-processing method with depth-dependent collimator resolution applied to full-time and half-time acquisitions without and with simultaneously acquired attenuation correction.

Authors:  Carmelo V Venero; Gary V Heller; Timothy M Bateman; A Iain McGhie; Alan W Ahlberg; Deborah Katten; Staci A Courter; Robert J Golub; James A Case; S James Cullom
Journal:  J Nucl Cardiol       Date:  2009-07-07       Impact factor: 5.952

9.  EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision.

Authors:  Hein J Verberne; Wanda Acampa; Constantinos Anagnostopoulos; Jim Ballinger; Frank Bengel; Pieter De Bondt; Ronny R Buechel; Alberto Cuocolo; Berthe L F van Eck-Smit; Albert Flotats; Marcus Hacker; Cecilia Hindorf; Philip A Kaufmann; Oliver Lindner; Michael Ljungberg; Markus Lonsdale; Alain Manrique; David Minarik; Arthur J H A Scholte; Riemer H J A Slart; Elin Trägårdh; Tim C de Wit; Birger Hesse
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-08-21       Impact factor: 9.236

10.  Clinical validation of time reduction strategy in continuous step-and-shoot mode during SPECT acquisition.

Authors:  Valentin Picone; Nikolaos Makris; Fanny Boutevin; Sarah Roy; Margot Playe; Michael Soussan
Journal:  EJNMMI Phys       Date:  2021-02-02
View more
  2 in total

1.  Anthropomorphic cardiac phantom for dynamic SPECT.

Authors:  A Krakovich; U Zaretsky; E Gelbart; I Moalem; A Naimushin; E Rozen; M Scheinowitz; R Goldkorn
Journal:  J Nucl Cardiol       Date:  2022-06-27       Impact factor: 5.952

2.  Technical note: Partitioning of gated single photon emission computed tomography raw data for protocols optimization.

Authors:  Cleiton Cavalcante Queiroz; Marcos Antonio Dorea Machado; Antonio Augusto Brito Ximenes; Andre Gustavo Silva Pino; Eduardo Martins Netto
Journal:  J Appl Clin Med Phys       Date:  2021-12-17       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.