Detection of small metastatic brain tumors: comparison of 3D contrast-enhanced whole-brain black-blood imaging and MP-RAGE imaging.

Jaeseok Park1, Jinna Kim, Eunhye Yoo, Hyunyeol Lee, Jong-Hee Chang, Eung Yeop Kim.   

Abstract

OBJECTIVE: Early and accurate diagnosis of small metastatic brain tumors may affect outcomes and treatment strategies. For this reason, 3-dimensional (3D) thin-section imaging is preferred. However, with conventional contrast-enhanced (CE) 3D imaging, such as magnetization-prepared rapid gradient echo (MP-RAGE), many visually enhanced vessels may mimic small metastatic tumors, hindering tumor detection. CE black-blood single-slab 3D turbo-spin echo imaging (BB-ssTSE) was recently developed, which uses variable refocusing flip angles and flow-sensitizing gradient schemes, to enhance metastatic brain tumors while selectively suppressing blood vessels. The purpose of this work was to investigate the efficiency of the proposed CE BB-ssTSE in detecting small metastatic brain tumors as compared with conventional MP-RAGE.
MATERIALS AND METHODS: Numerical comparisons of MP-RAGE and BB-ssTSE were performed by simulation studies to investigate the signal/contrast behaviors of flowing blood and stationary CE tumors. For in vivo studies, we enrolled 35 patients (18 women; mean age, 58.1 years) with breast or lung cancer who underwent brain magnetic resonance imaging. After administering a double dose of contrast medium, whole-brain 2-dimensional T1-weighted imaging followed by high-resolution isotropic 3D BB-ssTSE and MP-RAGE was performed at 3.0 T. Two reviewers independently evaluated the presence of metastatic brain tumors using: (1) MP-RAGE; (2) BB-ssTSE; and (3) MP-RAGE + BB-ssTSE sequentially in 3 review sessions, 2 weeks apart. The lesions were classified by size into 2 groups: large (≥5 mm) and small (<5 mm). Both reviewers marked all tumors detected at each session. Another reviewer combined the results of the 2 reviewers and compared the detection rates of metastatic brain tumors between BB-ssTSE and MP-RAGE by using follow-up imaging. Intraclass correlation coefficients between the 2 reviewers were measured.
RESULTS: Numerical simulations showed that the proposed BB-ssTSE effectively attenuated the signal intensity of flowing blood over the entire echo train, resulting in CE tumor-to-white matter contrast comparable with conventional MP-RAGE. The combined evaluation of MP-RAGE + BB-ssTSE showed 242 tumors in 28 patients. Of these, 153 lesions were <5 mm. MP-RAGE found 111 small metastatic brain tumors, BB-ssTSE found 150, and MP-RAGE + BB-ssTSE found 153. Significantly, more small tumors were detected by BB-ssTSE than MP-RAGE (P = 0.001, Wilcoxon signed-rank test). All large tumors were detected similarly by both MP-RAGE and BB-ssTSE. By combined results for MP-RAGE + BB-ssTSE, sensitivities for detection of small metastatic tumors were 72.5% for MP-RAGE and 98.0% for BB-ssTSE (P < 0.0001, McNemar test). Intraclass correlation coefficients between the 2 reviewers were 0.826 for MP-RAGE and 0.954 for BB-ssTSE.
CONCLUSION: Compared with conventional MP-RAGE, the proposed CE BB-ssTSE imaging, which enhances tumors while selectively suppressing blood vessels, leads to significantly better detection of small metastatic brain tumors <5 mm.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22104961     DOI: 10.1097/RLI.0b013e3182319704

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  15 in total

Review 1.  Diagnostic Clinical Trials in Breast Cancer Brain Metastases: Barriers and Innovations.

Authors:  Jawad Fares; Deepak Kanojia; Aida Rashidi; Atique U Ahmed; Irina V Balyasnikova; Maciej S Lesniak
Journal:  Clin Breast Cancer       Date:  2019-06-05       Impact factor: 3.225

2.  Deep-Learning Detection of Cancer Metastases to the Brain on MRI.

Authors:  Min Zhang; Geoffrey S Young; Huai Chen; Jing Li; Lei Qin; J Ricardo McFaline-Figueroa; David A Reardon; Xinhua Cao; Xian Wu; Xiaoyin Xu
Journal:  J Magn Reson Imaging       Date:  2020-03-13       Impact factor: 4.813

Review 3.  The detectability of brain metastases using contrast-enhanced spin-echo or gradient-echo images: a systematic review and meta-analysis.

Authors:  Chong Hyun Suh; Seung Chai Jung; Kyung Won Kim; Junhee Pyo
Journal:  J Neurooncol       Date:  2016-06-20       Impact factor: 4.130

4.  Consensus recommendations for a standardized brain tumor imaging protocol for clinical trials in brain metastases.

Authors:  Timothy J Kaufmann; Marion Smits; Jerrold Boxerman; Raymond Huang; Daniel P Barboriak; Michael Weller; Caroline Chung; Christina Tsien; Paul D Brown; Lalitha Shankar; Evanthia Galanis; Elizabeth Gerstner; Martin J van den Bent; Terry C Burns; Ian F Parney; Gavin Dunn; Priscilla K Brastianos; Nancy U Lin; Patrick Y Wen; Benjamin M Ellingson
Journal:  Neuro Oncol       Date:  2020-06-09       Impact factor: 12.300

5.  Comparison of contrast-enhanced T1-weighted imaging using DANTE-SPACE, PETRA, and MPRAGE: a clinical evaluation of brain tumors at 3 Tesla.

Authors:  Zi-Qiao Lei; Chuan-Sheng Zheng; Qing Fu; Qi-Guang Cheng; Xiang-Chuang Kong; Ding-Xi Liu; Yi-Hao Guo; John Grinstead; Xiao-Yong Zhang
Journal:  Quant Imaging Med Surg       Date:  2022-01

6.  Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging.

Authors:  D Kim; Y J Heo; H W Jeong; J W Baek; J-Y Han; J Y Lee; S-C Jin; H J Baek
Journal:  AJNR Am J Neuroradiol       Date:  2019-08-01       Impact factor: 3.825

7.  Comparison of contrast-enhanced modified T1-weighted 3D TSE black-blood and 3D MP-RAGE sequences for the detection of cerebral metastases and brain tumours.

Authors:  N N Kammer; E Coppenrath; K M Treitl; H Kooijman; O Dietrich; T Saam
Journal:  Eur Radiol       Date:  2015-09-03       Impact factor: 5.315

Review 8.  Brain metastases: An update on the multi-disciplinary approach of clinical management.

Authors:  D K Mitchell; H J Kwon; P A Kubica; W X Huff; R O'Regan; M Dey
Journal:  Neurochirurgie       Date:  2021-04-14       Impact factor: 1.553

9.  Improvement of the Diagnostic Performance of Facial Neuritis Using Contrast-Enhanced 3D T1 Black-Blood Imaging: Comparison with Contrast-Enhanced 3D T1-Spoiled Gradient-Echo Imaging.

Authors:  Seun-Ah Lee; Sang-Won Jo; Suk-Ki Chang; Ki-Han Kwon
Journal:  J Clin Med       Date:  2021-04-24       Impact factor: 4.241

10.  Utility of Contrast-Enhanced T2 FLAIR for Imaging Brain Metastases Using a Half-dose High-Relaxivity Contrast Agent.

Authors:  T Jin; M Ge; R Huang; Y Yang; T Liu; Q Zhan; Z Yao; H Zhang
Journal:  AJNR Am J Neuroradiol       Date:  2020-12-24       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.