Intense focused ultrasound can reliably induce sensations in human test subjects in a manner correlated with the density of their mechanoreceptors.

Trevor C Dickey1, Rowen Tych, Michel Kliot, John D Loeser, Kristin Pederson, Pierre D Mourad.   

Abstract

Sensations generated by intense focused ultrasound (iFU) can occur cutaneously and/or at depth, in contrast to other forms of stimulation (e.g., heat, electricity), whose action usually occurs only at the skin surface, or mechanical stimulation (e.g., von Frey hairs, calibrated forceps, tourniquets) that compress and thus stimulate all tissue. Previous work on iFU stimulation has led to the hypothesis that the tactile basis of iFU stimulation should correlate with the density of mechanoreceptors at the site of iFU stimulation. Here we tested that hypothesis, correlating a "two-point" neurological examination-a standard measure of superficial mechanoreceptor density-with the intensity of superficially applied iFU necessary to generate sensations with high sensitivity and specificity. We applied iFU at 1.1 MHz for 0.1 s to the fingertip pads of 17 test subjects in a blinded fashion and escalated intensities until they consistently observed iFU-induced sensations. Most test subjects achieved high values of sensitivity and specificity, doing so at values of spatially and temporally averaged intensity measuring <100 W/cm(2). Moreover, the test subjects' sensitivity to iFU stimulation correlated with the density of mechanoreceptors as determined by a standard two-point discrimination neurological examination, consistent with earlier hypotheses.
Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22104527      PMCID: PMC3245865          DOI: 10.1016/j.ultrasmedbio.2011.09.020

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  17 in total

Review 1.  Publishing nutrition research: a review of multivariate techniques--part 1.

Authors:  Patricia M Sheean; Barbara Bruemmer; Phillip Gleason; Jeffrey Harris; Carol Boushey; Linda Van Horn
Journal:  J Am Diet Assoc       Date:  2011-01

2.  An ultrasound mini-balance for measurement of therapy level ultrasound.

Authors:  Yvonne Sutton; Karne McBride; Stephen Pye
Journal:  Phys Med Biol       Date:  2006-06-26       Impact factor: 3.609

3.  Normal values for thermotactile and vibrotactile thresholds in males and females.

Authors:  Sue Ann Seah; Michael J Griffin
Journal:  Int Arch Occup Environ Health       Date:  2007-09-28       Impact factor: 3.015

4.  A study of reception with the use of focused ultrasound. II. Effects on the animal receptor structures.

Authors:  L R Gavrilov; G V Gersuni; O B Ilyinsky; E M Tsirulnikov; E E Shchekanov
Journal:  Brain Res       Date:  1977-10-28       Impact factor: 3.252

5.  Tactile sensibility in the human hand: relative and absolute densities of four types of mechanoreceptive units in glabrous skin.

Authors:  R S Johansson; A B Vallbo
Journal:  J Physiol       Date:  1979-01       Impact factor: 5.182

6.  Temporal summation of pain from skin, muscle and joint following nociceptive ultrasonic stimulation in humans.

Authors:  A Wright; T Graven-Nielsen; I I Davies; L Arendt-Nielsen
Journal:  Exp Brain Res       Date:  2002-04-23       Impact factor: 1.972

7.  Properties of cutaneous mechanoreceptors in the human hand related to touch sensation.

Authors:  A B Vallbo; R S Johansson
Journal:  Hum Neurobiol       Date:  1984

8.  A study of reception with the use of focused ultrasound. I. Effects on the skin and deep receptor structures in man.

Authors:  L R Gavrilov; G V Gersuni; O B Ilyinski; E M Tsirulnikov; E E Shchekanov
Journal:  Brain Res       Date:  1977-10-28       Impact factor: 3.252

Review 9.  Use of focused ultrasound for stimulation of nerve structures.

Authors:  L R Gavrilov
Journal:  Ultrasonics       Date:  1984-05       Impact factor: 2.890

Review 10.  Perception of ELF electromagnetic fields: excitation thresholds and inter-individual variability.

Authors:  N Leitgeb; J Schröttner; R Cech
Journal:  Health Phys       Date:  2007-06       Impact factor: 1.316

View more
  15 in total

1.  Displacement Imaging for Focused Ultrasound Peripheral Nerve Neuromodulation.

Authors:  Stephen A Lee; Hermes A S Kamimura; Mark T Burgess; Elisa E Konofagou
Journal:  IEEE Trans Med Imaging       Date:  2020-10-28       Impact factor: 10.048

2.  Neuropathic tissue responds preferentially to stimulation by intense focused ultrasound.

Authors:  Rowen E Tych; Michael Gofeld; Jeffrey G Jarvik; Michel Kliot; John D Loeser; Abbi M McClintic; Ryan J Ollos; Kristin D Pederson; Rachel E Sparks; Gregory W Terman; Pierre D Mourad
Journal:  Ultrasound Med Biol       Date:  2013-01       Impact factor: 2.998

3.  Rapid ultrasonic stimulation of inflamed tissue with diagnostic intent.

Authors:  Abbi M McClintic; Trevor C Dickey; Michael Gofeld; P Ray Illian; Michel Kliot; John C Kucewicz; John D Loeser; Philippe G Richebe; Pierre D Mourad
Journal:  J Acoust Soc Am       Date:  2013-08       Impact factor: 1.840

4.  Intense focused ultrasound as a potential research tool for the quantification of diurnal inflammatory pain.

Authors:  Josephine D Garcia; Michael Gofeld; P Ray Illian; John D Loeser; Michel Kliot; Abbi M McClintic; Alice Ward; Anning Yao; Pierre D Mourad
Journal:  Ultrasonics       Date:  2012-04-18       Impact factor: 2.890

5.  Intense focused ultrasound preferentially stimulates subcutaneous and focal neuropathic tissue: preliminary results.

Authors:  Abbi M McClintic; Trevor C Dickey; Michael Gofeld; Michel Kliot; John D Loeser; Philippe Richebe; Pierre D Mourad
Journal:  Pain Med       Date:  2012-11-08       Impact factor: 3.750

6.  Effective Ultrasonic Stimulation in Human Peripheral Nervous System.

Authors:  Thomas Riis; Jan Kubanek
Journal:  IEEE Trans Biomed Eng       Date:  2021-12-23       Impact factor: 4.756

7.  Displacement Imaging During Focused Ultrasound Median Nerve Modulation: A Preliminary Study in Human Pain Sensation Mitigation.

Authors:  Stephen A Lee; Hermes A S Kamimura; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

Review 8.  Focused Ultrasound (FUS) for Chronic Pain Management: Approved and Potential Applications.

Authors:  Lazzaro di Biase; Emma Falato; Maria Letizia Caminiti; Pasquale Maria Pecoraro; Flavia Narducci; Vincenzo Di Lazzaro
Journal:  Neurol Res Int       Date:  2021-06-29

9.  Pulsed ultrasound differentially stimulates somatosensory circuits in humans as indicated by EEG and FMRI.

Authors:  Wynn Legon; Abby Rowlands; Alexander Opitz; Tomokazu F Sato; William J Tyler
Journal:  PLoS One       Date:  2012-12-04       Impact factor: 3.240

10.  MR Neurography: Advances.

Authors:  Avneesh Chhabra; Lianxin Zhao; John A Carrino; Eo Trueblood; Saso Koceski; Filip Shteriev; Lionel Lenkinski; Christopher D J Sinclair; Gustav Andreisek
Journal:  Radiol Res Pract       Date:  2013-03-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.