Literature DB >> 22099906

Effect of canal length and curvature on working length alteration with WaveOne reciprocating files.

Elio Berutti1, Giorgio Chiandussi, Davide Salvatore Paolino, Nicola Scotti, Giuseppe Cantatore, Arnaldo Castellucci, Damiano Pasqualini.   

Abstract

INTRODUCTION: This study evaluated the working length (WL) modification after instrumentation with WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland) reciprocating files and the incidence of overinstrumentation in relation to the initial WL.
METHODS: Thirty-two root canals of permanent teeth were used. The angles of curvature of the canals were calculated on digital radiographs. The initial WL with K-files was transferred to the matched WaveOne Primary reciprocating files. After glide paths were established with PathFile (Dentsply Maillefer, Ballaigues, Switzerland), canals were shaped with WaveOne Primary referring to the initial WL. The difference between the postinstrumentation canal length and the initial canal length was analyzed by using a fiberoptic inspection microscope. Data were analyzed with a balanced 2-way factorial analysis of variance (P < .05).
RESULTS: Referring to the initial WL, 24 of 32 WaveOne Primary files projected beyond the experimental apical foramen (minimum-maximum, 0.14-0.76 mm). A significant decrease in the canal length after instrumentation (95% confidence interval ranging from -0.34 mm to -0.26 mm) was detected. The canal curvature significantly influenced the WL variation (F(1) = 30.65, P < .001). The interaction between the initial canal length and the canal curvature was statistically significant (F(2) = 4.38, P = .014).
CONCLUSIONS: Checking the WL before preparation of the apical third of the root canal is recommended when using the new WaveOne NiTi single-file system.
Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Mesh:

Substances:

Year:  2011        PMID: 22099906     DOI: 10.1016/j.joen.2011.09.014

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  16 in total

1.  The use of cone beam computed tomography to predetermine root canal lengths in molar teeth: a comparison between two-dimensional and three-dimensional measurements.

Authors:  J P Tchorz; P J Poxleitner; S Stampf; S B M Patzelt; D Rottke; E Hellwig; M J Altenburger
Journal:  Clin Oral Investig       Date:  2013-07-30       Impact factor: 3.573

2.  Reciproc and Reciproc Blue in the removal of bioceramic and resin-based sealers in retreatment procedures.

Authors:  Kaline Romeiro; Andressa de Almeida; Marcely Cassimiro; Luciana Gominho; Eugênia Dantas; Nayane Chagas; Christianne Velozo; Laila Freire; Diana Albuquerque
Journal:  Clin Oral Investig       Date:  2019-05-18       Impact factor: 3.573

3.  Comparison of microtomography and optical coherence tomography on apical endodontic filling analysis.

Authors:  Fernanda Clotilde Mariz Suassuna; Ana Marly Araújo Maia; Daniela Pita Melo; Antônio Celso Dantas Antonino; Anderson Stevens Leônidas Gomes; Patrícia Meira Bento
Journal:  Dentomaxillofac Radiol       Date:  2017-11-16       Impact factor: 2.419

4.  Effect of Sodium Hypochlorite Concentration on Electronic Apex Locator Reliability.

Authors:  Franck Diemer; Emma Plews; Marie Georgelin-Gurgel; Lora Mishra; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2022-01-23       Impact factor: 3.623

5.  Canal shaping with WaveOne reciprocating files: influence of operator experience on instrument breakage and canal preparation time.

Authors:  Luigi Generali; Elena Righi; Maria Vittoria Todesca; Ugo Consolo
Journal:  Odontology       Date:  2013-06-28       Impact factor: 2.634

6.  Root canal shaping by single-file systems and rotary instruments: a laboratory study.

Authors:  Khaly Bane; Babacar Faye; Mouhamed Sarr; Seydina O Niang; Diouma Ndiaye; Pierre Machtou
Journal:  Iran Endod J       Date:  2015-03-18

7.  Shaping ability of ProTaper Universal, WaveOne and ProTaper Next in simulated L-shaped and S-shaped root canals.

Authors:  Hui Wu; Cheng Peng; Yulong Bai; Xin Hu; Lei Wang; Changyi Li
Journal:  BMC Oral Health       Date:  2015-03-01       Impact factor: 2.757

8.  Shaping ability of reciprocating motion of WaveOne and HyFlex in moderate to severe curved canals: A comparative study with cone beam computed tomography.

Authors:  Gurram Samuel Simpsy; Girija S Sajjan; Padmaja Mudunuri; Jyothi Chittem; Nalam N V D Prasanthi; Pankaj Balaga
Journal:  J Conserv Dent       Date:  2016 Nov-Dec

9.  Centering Ability and Influence of Experience When Using WaveOne Single-File Technique in Simulated Canals.

Authors:  Mathieu Goldberg; Sandrine Dahan; Pierre Machtou
Journal:  Int J Dent       Date:  2012-10-16

10.  Cone-Beam Computed Tomography Assessment of Root Canal Transportation by Neoniti and Reciproc Single-File Systems.

Authors:  Fariborz Moazzami; Leila Khojastepour; Mohammadreza Nabavizadeh; Mina Seied Habashi
Journal:  Iran Endod J       Date:  2016-03-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.