Mobile or fixed unicompartmental knee prostheses? In-vitro wear assessments to solve this dilemma.

P Taddei1, E Modena, Thomas M Grupp, Saverio Affatato.   

Abstract

The unicompartmental knee prosthesis is an attractive alternative to total knee arthroplasty. Current UKP devices can be subdivided into two groups based on different design principles: fixed bearing knees, where the ultra-high molecular weight polyethylene meniscal component snap or press fits into the tibial tray, and mobile bearing designs which facilitate movement of the insert relative to the tray. The present study was aimed at comparing the in-vitro wear behaviour of fixed and mobile unicompartmental knee menisci under two configurations: the femoral components were cemented into a custom-made metallic block or, as a novelty of the present study, into a synthetic femur (i.e. under conditions which should better reproduce the in-vivo behaviour). Analyses were performed using a displacement-control knee wear simulator with "three-plus-one" stations. All the kinematics tests were set in accordance with the ISO 14243-1,2,3. Fixed and mobile polyethylene menisci showed a different wear behaviour: the fixation-frame influenced directional load transfer through each component in a qualitative and quantitative way. In fact, gravimetric results showed that under the metal block holder fixation, mobile components worn more than fixed components (weight losses of 8.7±2.0 mg and 2.6±1.09 mg, respectively); on the other hand, under the synthetic femur configuration, differences in wear behaviour were less pronounced and mobile menisci underwent a slightly lower weight loss than fixed components (4.5±2.2 mg vs. 6.7±1.4 mg). This different trend was explained in relation to the kinematic schemes of the two fixation methods. Raman spectroscopy, used to evaluate the UHMWPE crystallinity changes induced by mechanical stress, showed that mobile menisci specimens were more affected than the fixed components in both their superior and inferior surfaces, independent of the fixation-frame. In conclusion, if tested under conditions which should better reproduce the in-vivo behaviour, mobile UKPs did not show a worse wear behaviour than fixed components in terms of weight losses, although UHMWPE changes at the molecular scale could be detrimental.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22098892     DOI: 10.1016/j.jmbbm.2011.06.010

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  6 in total

1.  Toward the interpretation of the combined effect of size and body weight on the tribological performance of total knee prostheses.

Authors:  Santina Battaglia; Paola Taddei; Silvia Tozzi; Alessandra Sudanese; Saverio Affatato
Journal:  Int Orthop       Date:  2014-02-26       Impact factor: 3.075

2.  Preliminary In Vitro Wear Assessment of Ceramic Cemented Femoral Components Coupled with Polyethylene Menisci.

Authors:  Saverio Affatato; Paolo Erani; Maurizio Fersini; Vincenzo Contaldi; Anna Rita Terrizzi; Antonio Licciulli
Journal:  Materials (Basel)       Date:  2021-04-22       Impact factor: 3.623

3.  Retrospective Clinical and Radiological Outcomes after Robotic Assisted Bicompartmental Knee Arthroplasty.

Authors:  Cuneyt Tamam; Johannes F Plate; Marco Augart; Gary G Poehling; Riyaz H Jinnah
Journal:  Adv Orthop       Date:  2015-09-03

4.  Increase in the tibial slope reduces wear after medial unicompartmental fixed-bearing arthroplasty of the knee.

Authors:  Patrick Weber; Christian Schröder; Jens Schwiesau; Sandra Utzschneider; Arnd Steinbrück; Matthias F Pietschmann; Volkmar Jansson; Peter E Müller
Journal:  Biomed Res Int       Date:  2015-01-15       Impact factor: 3.411

5.  Wear Behavior Characterization of Hydrogels Constructs for Cartilage Tissue Replacement.

Authors:  Saverio Affatato; Diego Trucco; Paola Taddei; Lorenzo Vannozzi; Leonardo Ricotti; Gilbert Daniel Nessim; Gina Lisignoli
Journal:  Materials (Basel)       Date:  2021-01-16       Impact factor: 3.623

6.  Achieving accurate ligament balancing using robotic-assisted unicompartmental knee arthroplasty.

Authors:  Johannes F Plate; Ali Mofidi; Sandeep Mannava; Beth P Smith; Jason E Lang; Gary G Poehling; Michael A Conditt; Riyaz H Jinnah
Journal:  Adv Orthop       Date:  2013-03-24
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.