Literature DB >> 22095996

Renal perfusion 3-T MR imaging: a comparative study of arterial spin labeling and dynamic contrast-enhanced techniques.

Wen-Chau Wu1, Mao-Yuan Su, Chin-Cheng Chang, Wen-Yih Isaac Tseng, Kao-Lang Liu.   

Abstract

PURPOSE: To investigate the feasibility of and correlation between arterial spin-labeling (ASL) and dynamic contrast material-enhanced (DCE) 3-T magnetic resonance (MR) imaging in the measurement of renal blood flow (RBF).
MATERIALS AND METHODS: The review board approved this study. Nineteen healthy volunteers (seven women, 12 men; age range, 25-68 years) were recruited, and each provided written informed consent. MR imaging was performed with a 3-T whole-body system. Each subject underwent back-to-back ASL and DCE MR imaging. Ten runs of ASL imaging were performed by using the pseudocontinuous tagging scheme, and each run required an 18-second breath hold. For DCE imaging, a gadopentetate dimeglumine bolus (0.0125 mmol per kilogram of body weight) was administrated intravenously in all subjects except two; in the latter subjects, a 0.025 mmol/kg gadopentetate dimeglumine bolus was administered to evaluate the T1 saturation effect. RBF was quantified with both techniques and in both the cortex and the medulla. Agreement was evaluated for RBF measurements obtained with ASL imaging and those obtained with DCE imaging by using correlation analysis.
RESULTS: RBF was apparently overestimated with 0.025 mmol/kg gadopentetate dimeglumine, which is a concentration that is commonly adopted for 1.5-T DCE. RBF was 227 mL/100 mL/min ± 30 (standard deviation) in the cortex and 101 mL/100 mL/min ± 21 in the medulla, as measured with ASL imaging, and 272 mL/100 mL/min ± 60 in the cortex and 122 mL/100 mL/min ± 30 in the medulla, as measured with DCE imaging. In the cortex, measurements obtained with ASL and DCE imaging exhibited a linear correlation (r = 0.66; statistical power, 0.8 at the 5% significance level) and fair agreement (intraclass correlation coefficient, 0.41).
CONCLUSION: ASL and DCE 3-T MR imaging are feasible in the quantification of cortical renal perfusion, yielding measurements that are correlated but not entirely comparable. Intermodality differences have yet to be solved. © RSNA, 2011.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22095996     DOI: 10.1148/radiol.11110668

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  27 in total

1.  Using intravoxel incoherent motion MR imaging to study the renal pathophysiological process of contrast-induced acute kidney injury in rats: Comparison with conventional DWI and arterial spin labelling.

Authors:  Long Liang; Wen-Bo Chen; Kannie W Y Chan; Yu-Guo Li; Bin Zhang; Chang-Hong Liang; Guan-Shu Liu; Shui-Xing Zhang
Journal:  Eur Radiol       Date:  2015-09-15       Impact factor: 5.315

Review 2.  Perfluorocarbon nanoparticles for physiological and molecular imaging and therapy.

Authors:  Junjie Chen; Hua Pan; Gregory M Lanza; Samuel A Wickline
Journal:  Adv Chronic Kidney Dis       Date:  2013-11       Impact factor: 3.620

3.  Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility.

Authors:  Marica Cutajar; David L Thomas; Patrick W Hales; T Banks; Christopher A Clark; Isky Gordon
Journal:  Eur Radiol       Date:  2014-03-06       Impact factor: 5.315

4.  Arterial spin labelling MRI to measure renal perfusion: a systematic review and statement paper.

Authors:  Aghogho Odudu; Fabio Nery; Anita A Harteveld; Roger G Evans; Douglas Pendse; Charlotte E Buchanan; Susan T Francis; María A Fernández-Seara
Journal:  Nephrol Dial Transplant       Date:  2018-09-01       Impact factor: 5.992

5.  Respiratory motion prediction and prospective correction for free-breathing arterial spin-labeled perfusion MRI of the kidneys.

Authors:  Hao Song; Dan Ruan; Wenyang Liu; V Andrew Stenger; Rolf Pohmann; Maria A Fernández-Seara; Tejas Nair; Sungkyu Jung; Jingqin Luo; Yuichi Motai; Jingfei Ma; John D Hazle; H Michael Gach
Journal:  Med Phys       Date:  2017-02-21       Impact factor: 4.071

6.  Consistency of Multiple Renal Functional MRI Measurements Over 18 Months.

Authors:  Lu-Ping Li; Jon Thacker; Wei Li; Huan Tan; Chi Wang; Orly Kohn; Stuart Sprague; Pottumarthi Prasad
Journal:  J Magn Reson Imaging       Date:  2018-03-08       Impact factor: 4.813

7.  Tumor Vascularity in Renal Masses: Correlation of Arterial Spin-Labeled and Dynamic Contrast-Enhanced Magnetic Resonance Imaging Assessments.

Authors:  Yue Zhang; Payal Kapur; Qing Yuan; Yin Xi; Ingrid Carvo; Sabina Signoretti; Ivan Dimitrov; Jeffrey A Cadeddu; Vitaly Margulis; Naira Muradyan; James Brugarolas; Ananth J Madhuranthakam; Ivan Pedrosa
Journal:  Clin Genitourin Cancer       Date:  2015-08-29       Impact factor: 2.872

8.  Statistical clustering of parametric maps from dynamic contrast enhanced MRI and an associated decision tree model for non-invasive tumour grading of T1b solid clear cell renal cell carcinoma.

Authors:  Yin Xi; Qing Yuan; Yue Zhang; Ananth J Madhuranthakam; Michael Fulkerson; Vitaly Margulis; James Brugarolas; Payal Kapur; Jeffrey A Cadeddu; Ivan Pedrosa
Journal:  Eur Radiol       Date:  2017-07-05       Impact factor: 5.315

9.  Renal perfusion imaging with two-dimensional navigator gated arterial spin labeling.

Authors:  Huan Tan; Ioannis Koktzoglou; Pottumarthi V Prasad
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

10.  Assessing intrarenal nonperfusion and vascular leakage in acute kidney injury with multinuclear (1) H/(19) F MRI and perfluorocarbon nanoparticles.

Authors:  Lingzhi Hu; Junjie Chen; Xiaoxia Yang; Angana Senpan; John S Allen; Noriko Yanaba; Shelton D Caruthers; Gregory M Lanza; Marc R Hammerman; Samuel A Wickline
Journal:  Magn Reson Med       Date:  2013-08-08       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.