Literature DB >> 22081300

Bone screws have advantages in repair of experimental osteochondral fragments.

Michihaya Kono1, Ryuji Mori, Yuji Uchio.   

Abstract

BACKGROUND: Cartilage defects are created on intraarticular osteochondral fragments at the entrance holes of fixation devices when these fragments are fixed to the original sites. Conventional fixation devices hinder repair of these defects and there is a latent risk of secondary osteoarthritis. We therefore developed a novel fixation device system consisting of bone screws made of cortical bone for osteochondral fragments to improve repair of these surface defects. QUESTIONS/PURPOSES: We asked whether bone screws had advantages over poly-L-lactic acid (PLLA) screws in terms of (1) gross assessment of the surface, (2) volume and histologic quality of the repair tissue, and (3) biomechanical assessment of the tissue stiffness.
METHODS: We examined gross morphology, microCT, histology, and stiffness of the repaired tissue with PLLA (n = 32) and bone (n = 32) screws in a rabbit model of osteochondral fracture, compared with normal controls (n = 16).
RESULTS: Gross morphology and histology revealed better quality with bone screws than with PLLA screws. Mean repaired volumes in microCT were 70.6% ± 14% with bone screws and 50.3% ± 15% with PLLA screws. Average stiffness values for PLLA screws, bone screws, and normal cartilage were 1.67 ± 0.54 N/mm, 2.63 ± 0.42 N/mm, and 3.15 ± 0.49 N/mm, respectively.
CONCLUSIONS: Our results show better repaired tissue was observed for quality and quantity when chondral fractures were treated with bone screws than when treated with PLLA screws. CLINICAL RELEVANCE: Bone screws made of cortical bone may have applications in clinical situations for the fixation of intraarticular osteochondral fragments.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22081300      PMCID: PMC3369084          DOI: 10.1007/s11999-011-2175-5

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  25 in total

Review 1.  Bioabsorbable implants in orthopaedics: new developments and clinical applications.

Authors:  W J Ciccone; C Motz; C Bentley; J P Tasto
Journal:  J Am Acad Orthop Surg       Date:  2001 Sep-Oct       Impact factor: 3.020

2.  Osteochondral fractures and their relationship to osteochondritis dissecans of the knee. An experimental study in animals.

Authors:  P Aichroth
Journal:  J Bone Joint Surg Br       Date:  1971-08

3.  Bioconvertible screws made of allogenic cortical bone for osteosynthesis following sagittal split ramus osteotomy without postoperative immobilisation.

Authors:  J A Obwegeser
Journal:  J Craniomaxillofac Surg       Date:  1994-04       Impact factor: 2.078

4.  Tibial cortical bone peg fixation in osteochondritis dissecans of the knee.

Authors:  J A Slough; A M Noto; T L Schmidt
Journal:  Clin Orthop Relat Res       Date:  1991-06       Impact factor: 4.176

5.  Biomechanical and histological evaluation of osteochondral transplantation in a rabbit model.

Authors:  Ellis K Nam; Mohsen Makhsous; Jason Koh; Mark Bowen; Gordon Nuber; Li-Qun Zhang
Journal:  Am J Sports Med       Date:  2004-03       Impact factor: 6.202

6.  Fixation of osteochondral fragments in the knee joint. A clinical survey.

Authors:  S Lindholm; P Pylkkänen; K Osterman
Journal:  Clin Orthop Relat Res       Date:  1977 Jul-Aug       Impact factor: 4.176

7.  Cell origin and differentiation in the repair of full-thickness defects of articular cartilage.

Authors:  F Shapiro; S Koide; M J Glimcher
Journal:  J Bone Joint Surg Am       Date:  1993-04       Impact factor: 5.284

8.  Sensitivity of indentation testing to step-off edges and interface integrity in cartilage repair.

Authors:  Won C Bae; Amanda W Law; David Amiel; Robert L Sah
Journal:  Ann Biomed Eng       Date:  2004-03       Impact factor: 3.934

Review 9.  Articular cartilage repair: basic science and clinical progress. A review of the current status and prospects.

Authors:  E B Hunziker
Journal:  Osteoarthritis Cartilage       Date:  2002-06       Impact factor: 6.576

10.  Xenogeneic bone grafting in humans.

Authors:  R Salama
Journal:  Clin Orthop Relat Res       Date:  1983-04       Impact factor: 4.176

View more
  2 in total

Review 1.  [Is routine implant removal after trauma surgery sensible?].

Authors:  C Krettek; C Müller; R Meller; M Jagodzinski; F Hildebrand; R Gaulke
Journal:  Unfallchirurg       Date:  2012-04       Impact factor: 1.000

2.  Clinical outcomes after absorbable suture fixation of patellar osteochondral fracture following patellar dislocation.

Authors:  Zu-Xi Li; Huang-He Song; Qing Wang; Dun-Ming Guo
Journal:  Ann Transl Med       Date:  2019-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.