Literature DB >> 22061446

Performance of longitudinal and volumetric tube current modulation in a 64-slice CT with different choices of acquisition and reconstruction parameters.

Aart J Van der Molen1, Raoul M S Joemai, Jacob Geleijns.   

Abstract

Aim of the study was to evaluate the performance of a tube current modulation (TCM) system ((SURE)Exposure 3D). On a 64 detector-row CT scanner (Aquilion 64, Toshiba), performance of fixed tube current, longitudinal TCM, and volumetric TCM acquisitions were assessed. A homogeneous cone-shaped phantom and an anthropomorphic phantom were used. Tube current and noise profiles were quantitatively analysed by box and whisker plots when phantom size, acquisition, and reconstruction parameters were varied. At similar median noise, fixed tube current scanning showed a noise range of 16.8-38.3 HU, while longitudinal TCM showed a range of 19.4-31.4 HU and volumetric TCM showed an even lower range of 20.7-28.7 HU. When acquisitions resulting in similar image quality (noise) were compared, the use of volumetric compared to longitudinal TCM resulted in a variable radiation dose reduction up to 6.6%. In conclusion, (SURE)Exposure 3D resulted in more uniform image quality at a lower dose. Volumetric TCM shows improved results over longitudinal TCM.
Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Mesh:

Year:  2011        PMID: 22061446     DOI: 10.1016/j.ejmp.2011.10.005

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  13 in total

1.  Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake.

Authors:  Yue-Ying Pan; Shu-Chang Zhou; Yu-Jin Wang; Qian Li; Ting-Ting Zhu; Chun-Xia Liu; Han-Xiong Guan
Journal:  Curr Med Sci       Date:  2020-03-13

2.  Effective dose and organ doses estimation taking tube current modulation into account with a commercial software package.

Authors:  X Lopez-Rendon; H Bosmans; R Oyen; F Zanca
Journal:  Eur Radiol       Date:  2015-02-14       Impact factor: 5.315

3.  Superior CT coronary angiography image quality at lower radiation exposure with second generation 320-detector row CT in patients with elevated heart rate: a comparison with first generation 320-detector row CT.

Authors:  Dennis T L Wong; Siang Y Soh; Brian S H Ko; James D Cameron; Marcus Crossett; Arthur Nasis; John Troupis; Ian T Meredith; Sujith K Seneviratne
Journal:  Cardiovasc Diagn Ther       Date:  2014-08

4.  Differences in behavior of tube current modulation techniques for thoracic CT examinations between male and female anthropomorphic phantoms.

Authors:  Kosuke Matsubara; Pei-Jan Paul Lin; Atsushi Fukuda; Kichiro Koshida
Journal:  Radiol Phys Technol       Date:  2014-05-27

5.  Using 80 kVp on a 320-row scanner for hepatic multiphasic CT reduces the contrast dose by 50 % in patients at risk for contrast-induced nephropathy.

Authors:  Narumi Taguchi; Seitaro Oda; Daisuke Utsunomiya; Yoshinori Funama; Takeshi Nakaura; Masanori Imuta; Sadahiro Yamamura; Hideaki Yuki; Masafumi Kidoh; Kenichiro Hirata; Tomohiro Namimoto; Masahiro Hatemura; Noriyuki Kai; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2016-05-30       Impact factor: 5.315

6.  Rest and stress transluminal attenuation gradient and contrast opacification difference for detection of hemodynamically significant stenoses in patients with suspected coronary artery disease.

Authors:  Brian S Ko; Sujith Seneviratne; James D Cameron; Sarah Gutman; Marcus Crossett; Kiran Munnur; Ian T Meredith; Dennis T L Wong
Journal:  Int J Cardiovasc Imaging       Date:  2016-03-07       Impact factor: 2.357

7.  Dual-region-of-interest bolus-tracking technique for coronary computed tomographic angiography on a 320-row scanner: reduction in the interpatient variability of arterial contrast enhancement.

Authors:  Noriyuki Kai; Seitaro Oda; Daisuke Utsunomiya; Takeshi Nakaura; Yoshinori Funama; Masafumi Kidoh; Narumi Taguchi; Yuji Iyama; Yasunori Nagayama; Kenichiro Hirata; Hideaki Yuki; Daisuke Sakabe; Masahiro Hatemura; Yasuyuki Yamashita
Journal:  Br J Radiol       Date:  2017-11-08       Impact factor: 3.039

8.  Physical validation of a Monte Carlo-based, phantom-derived approach to computed tomography organ dosimetry under tube current modulation.

Authors:  Elliott J Stepusin; Daniel J Long; Kayla R Ficarrotta; David E Hintenlang; Wesley E Bolch
Journal:  Med Phys       Date:  2017-09-22       Impact factor: 4.071

9.  Impact of heart rate on diagnostic accuracy of second generation 320-detector computed tomography coronary angiography.

Authors:  Nitesh Nerlekar; Brian S Ko; Arthur Nasis; James D Cameron; Michael Leung; Adam J Brown; Dennis T L Wong; Philip J Ngu; John M Troupis; Sujith K Seneviratne
Journal:  Cardiovasc Diagn Ther       Date:  2017-06

10.  Submillisievert median radiation dose for coronary angiography with a second-generation 320-detector row CT scanner in 107 consecutive patients.

Authors:  Marcus Y Chen; Sujata M Shanbhag; Andrew E Arai
Journal:  Radiology       Date:  2013-01-22       Impact factor: 11.105

View more