Literature DB >> 22058647

Feature Guided Motion Artifact Reduction with Structure-Awareness in 4D CT Images.

Dongfeng Han1, John Bayouth, Qi Song, Sudershan Bhatia, Milan Sonka, Xiaodong Wu.   

Abstract

In this paper, we propose a novel method to reduce the magnitude of 4D CT artifacts by stitching two images with a data-driven regularization constrain, which helps preserve the local anatomy structures. Our method first computes an interface seam for the stitching in the overlapping region of the first image, which passes through the "smoothest" region, to reduce the structure complexity along the stitching interface. Then, we compute the displacements of the seam by matching the corresponding interface seam in the second image. We use sparse 3D features as the structure cues to guide the seam matching, in which a regularization term is incorporated to keep the structure consistency. The energy function is minimized by solving a multiple-label problem in Markov Random Fields with an anatomical structure preserving regularization term. The displacements are propagated to the rest of second image and the two image are stitched along the interface seams based on the computed displacement field. The method was tested on both simulated data and clinical 4D CT images. The experiments on simulated data demonstrated that the proposed method was able to reduce the landmark distance error on average from 2.9 mm to 1.3 mm, outperforming the registration-based method by about 55%. For clinical 4D CT image data, the image quality was evaluated by three medical experts, and all identified much fewer artifacts from the resulting images by our method than from those by the compared method.

Entities:  

Year:  2011        PMID: 22058647      PMCID: PMC3207360          DOI: 10.1109/CVPR.2011.5995561

Source DB:  PubMed          Journal:  Proc IEEE Comput Soc Conf Comput Vis Pattern Recognit        ISSN: 1063-6919


  10 in total

1.  Optimal graph search segmentation using arc-weighted graph for simultaneous surface detection of bladder and prostate.

Authors:  Qi Song; Xiaodong Wu; Yunlong Liu; Mark Smith; John Buatti; Milan Sonka
Journal:  Med Image Comput Comput Assist Interv       Date:  2009

2.  Optimal surface segmentation in volumetric images--a graph-theoretic approach.

Authors:  Kang Li; Xiaodong Wu; Danny Z Chen; Milan Sonka
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2006-01       Impact factor: 6.226

3.  Image stitching using structure deformation.

Authors:  Jiaya Jia; Chi-Keung Tang
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2008-04       Impact factor: 6.226

4.  elastix: a toolbox for intensity-based medical image registration.

Authors:  Stefan Klein; Marius Staring; Keelin Murphy; Max A Viergever; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2009-11-17       Impact factor: 10.048

5.  Characterization and identification of spatial artifacts during 4D-CT imaging.

Authors:  Dongfeng Han; John Bayouth; Sudershan Bhatia; Milan Sonka; Xiaodong Wu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

6.  A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT.

Authors:  Wei Lu; Parag J Parikh; James P Hubenschmidt; Jeffrey D Bradley; Daniel A Low
Journal:  Med Phys       Date:  2006-08       Impact factor: 4.071

7.  Synchronized moving aperture radiation therapy (SMART): improvement of breathing pattern reproducibility using respiratory coaching.

Authors:  Toni Neicu; Ross Berbeco; John Wolfgang; Steve B Jiang
Journal:  Phys Med Biol       Date:  2006-01-19       Impact factor: 3.609

8.  An optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing.

Authors:  Jan Ehrhardt; René Werner; Dennis Säring; Thorsten Frenzel; Wei Lu; Daniel Low; Heinz Handels
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

9.  Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients.

Authors:  Tokihiro Yamamoto; Ulrich Langner; Billy W Loo; John Shen; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-25       Impact factor: 7.038

10.  4D CT sorting based on patient internal anatomy.

Authors:  Ruijiang Li; John H Lewis; Laura I Cerviño; Steve B Jiang
Journal:  Phys Med Biol       Date:  2009-07-22       Impact factor: 3.609

  10 in total
  3 in total

1.  Reconstruction of four-dimensional computed tomography lung images by applying spatial and temporal anatomical constraints using a Bayesian model.

Authors:  Tiancheng He; Zhong Xue; Bin S Teh; Stephen T Wong
Journal:  J Med Imaging (Bellingham)       Date:  2015-05-13

2.  Rapid estimation of 4DCT motion-artifact severity based on 1D breathing-surrogate periodicity.

Authors:  Guang Li; Marshall Caraveo; Jie Wei; Andreas Rimner; Abraham J Wu; Karyn A Goodman; Ellen Yorke
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

3.  Assessment of a quantitative metric for 4D CT artifact evaluation by observer consensus.

Authors:  Sarah J Castillo; Richard Castillo; Peter Balter; Tinsu Pan; Geoffrey Ibbott; Brian Hobbs; Ying Yuan; Thomas Guerrero
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.