Literature DB >> 22051229

Open reduction internal fixation versus percutaneous pinning with external fixation of distal radius fractures: a prospective, randomized clinical trial.

Ruby Grewal1, Joy C MacDermid, Graham J W King, Kenneth J Faber.   

Abstract

PURPOSE: The purpose of this randomized clinical trial was to investigate the functional outcomes of the surgical treatment of distal radius fractures, comparing treatment by external fixation and percutaneous pinning to open reduction and internal fixation (ORIF) using a plate.
METHODS: We randomized 53 patients with distal radius fractures that failed closed reduction and casting to ORIF (n = 27) or external fixation (n = 26). For pragmatic reasons, the choice of ORIF was left to the surgeon's discretion (early recruitment, dorsal plates [n = 9]; later recruitment, volar locked plates [n = 18]). Outcomes were measured before surgery, at 6 weeks, and at 3, 6, and 12 months and included the Patient-Rated Wrist Evaluation (PRWE); Disabilities of the Arm, Shoulder, and Hand; range of motion; grip strength; and serial radiographic analysis. Generalized linear modeling using repeated measures was used to identify differences in outcome scores between fixation types over time. Other continuous variables were analyzed using the Student t-test or one-way analysis of variance for multiple groups.
RESULTS: There were no differences in the demographic characteristics or fracture severity between groups. Based on generalized linear modeling, on average, the ORIF group scored 11 points lower on the PRWE across all time points compared to the external fixation group. The PRWE detected higher pain and disability with external fixation before surgery, at 6 weeks, and at 3 months. Using generalized linear modeling, a post hoc subgroup analysis identified significantly better (15-point advantage) PRWE scores averaged across all time points with volar locking plates compared to both external fixation and dorsal plating.
CONCLUSIONS: The PRWE scores were significantly lower for patients treated with ORIF compared to those with external fixation, with the best outcomes observed with volar locking plates. These advantages were observed in the early postoperative period, and overall scores equalized at 1 year. A higher mean initial preoperative PRWE score was seen with external fixation, perhaps indicating a more severe initial injury. Given this difference, the interpretation of these results is not clear.
Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22051229     DOI: 10.1016/j.jhsa.2011.09.015

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  39 in total

1.  Outcomes following operative treatment of open fractures of the distal radius: a case control study.

Authors:  Brendan J MacKay; Nicole Montero; Nader Paksima; Kenneth A Egol
Journal:  Iowa Orthop J       Date:  2013

2.  The Cost-Effectiveness of Surgical Fixation of Distal Radial Fractures: A Computer Model-Based Evaluation of Three Operative Modalities.

Authors:  Prashant V Rajan; Rameez A Qudsi; George S M Dyer; Elena Losina
Journal:  J Bone Joint Surg Am       Date:  2018-02-07       Impact factor: 5.284

3.  External fixation versus open reduction with locked volar plating for geriatric distal radius fractures.

Authors:  Daniel J Lee; John C Elfar
Journal:  Geriatr Orthop Surg Rehabil       Date:  2014-09

4.  Impact of Design on Force between Flexor Tendons and Distal Radius Volar Plates.

Authors:  Katharine M Hinchcliff; Ido Volk; Xenia Ivanova; Sandra Taylor; Robert M Szabo
Journal:  J Wrist Surg       Date:  2019-03-25

Review 5.  Is the external fixator yet useful for treating fractures of the distal radius?

Authors:  Michel Rongières
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-06-04

Review 6.  [Distal radius fractures : Current treatment concepts and controversies].

Authors:  S Thelen; J-P Grassmann; P Jungbluth; J Windolf
Journal:  Chirurg       Date:  2018-10       Impact factor: 0.955

7.  Performance and Return to Sport After Forearm Fracture Open Reduction and Internal Fixation in National Football League Players.

Authors:  Kyle R Sochacki; Robert A Jack; Takashi Hirase; Patrick C McCulloch; David M Lintner; Shari R Liberman; Joshua D Harris
Journal:  Hand (N Y)       Date:  2017-08-20

8.  Complications of Volar Plating of Distal Radius Fractures: A Systematic Review.

Authors:  Todd H Alter; Kristin Sandrowski; Gregory Gallant; Moody Kwok; Asif M Ilyas
Journal:  J Wrist Surg       Date:  2018-08-13

9.  Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures.

Authors:  Mert Kumbaraci; Levent Kucuk; Levent Karapinar; Cengizhan Kurt; Erhan Coskunol
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-02-16

10.  Treatment of unstable extra-articular distal radius fractures using locked volar plating and percutaneous pinning without external fixation.

Authors:  Saeid Sadeghi Joni; Pedram Yavari; Peyman Tavakoli; Pedram Tavoosi; Ghasem Mohammadsharifi
Journal:  Int J Burns Trauma       Date:  2020-08-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.