INTRODUCTION: One of the most common fractions is distal radius fracture, and various treatments have been suggested for this. The purpose of this study, is comparison of Open reduction and internal fixation by using a locked volar plating compared to percutaneous pinning by cast immobilization under the elbow in patients less than 60 years with good bone density that had unstable extra-articular distal radius fracture or UDRF.
METHODS: This study was clinical trial. 88 patients with closed UDRF who were referred for surgical treatment entered the study. Patients were randomized into two groups: group 1 had open reduction and internal fixation by using a locked volar plating and the other group had percutaneous pinning by cast immobilization surgeries. Amount of pain [by using Visual analog scale or VAS] and functional results of two methods were compared 3 and 12 month after surgeries.
FINDINGS: The intensity of pain was higher in the pinning group 3 and 12 month after treatment (P=0.001 and P=0.390 respectively). The range of motions in the plating group was significantly better (P<0.001). There was a significant difference in performing daily activities 3 month after treatment between the two groups, but a significant limitation in daily activities, observed 12 months after surgery in pinning group (P=0.004).
CONCLUSION: Bone fixation, using locked volar plating, can be a better modality with regard to postsurgical pain and also the wrist range of motion than percutaneous pinning with cast immobilization in patients younger than 60 years sustaining unstable, closed extra-articular, distal radius fracture. IJBT
Copyright © 2020.

Entities:  

Keywords:  Fixing fracture; radius fracture; surgery methods

Year:  2020        PMID: 32934865      PMCID: PMC7486567     

Source DB:  PubMed          Journal:  Int J Burns Trauma        ISSN: 2160-2026


  26 in total

1.  Surgical Strategy and Techniques for Low-Profile Dorsal Plating in Treating Dorsally Displaced Unstable Distal Radius Fractures.

Authors:  Yoshitaka Hamada; Hiroyuki Gotani; Naohito Hibino; Yoshitaka Tanaka; Ryousuke Satoh; Kousuke Sasaki; Thepparat Kanchanathepsak
Journal:  J Wrist Surg       Date:  2016-10-19

2.  Prospective Evaluation of Median Nerve Dysfunctions in Patients with a Distal Radius Fracture Treated with Volar Locking Plating.

Authors:  Fumihiro Isobe; Hiroshi Yamazaki; Masanori Hayashi; Shigeharu Uchiyama; Shunsuke Miyaoka; Hiroyuki Kato
Journal:  J Hand Surg Asian Pac Vol       Date:  2019-12

3.  Complications following open reduction and internal fixation versus external fixation in treating unstable distal radius fractures: Grading the evidence through a meta-analysis.

Authors:  Z Z Yuan; Z Yang; Q Liu; Y M Liu
Journal:  Orthop Traumatol Surg Res       Date:  2017-10-12       Impact factor: 2.256

4.  External Fixation Versus Volar Locking Plate for Unstable Dorsally Displaced Distal Radius Fractures-A 3-Year Follow-Up of a Randomized Controlled Study.

Authors:  Jenny Saving; Anders Enocson; Sari Ponzer; Cecilia Mellstrand Navarro
Journal:  J Hand Surg Am       Date:  2018-11-09       Impact factor: 2.230

5.  Complications of Volar Plating of Distal Radius Fractures: A Systematic Review.

Authors:  Todd H Alter; Kristin Sandrowski; Gregory Gallant; Moody Kwok; Asif M Ilyas
Journal:  J Wrist Surg       Date:  2018-08-13

6.  Complications of volar locking plating of distal radius fractures in 576 patients with 3.2 years follow-up.

Authors:  Rikke Thorninger; Mette Lund Madsen; Daniel Wæver; Lars Carl Borris; Jan Hendrik Duedal Rölfing
Journal:  Injury       Date:  2017-03-10       Impact factor: 2.586

7.  Quality of fracture reduction assessed by radiological parameters and its influence on functional results in patients with pilon fractures-A prospective multicentre study.

Authors:  Christoph Sommer; Sean E Nork; Matthew Graves; Michael Blauth; Mark Rudin; Karl Stoffel
Journal:  Injury       Date:  2017-10-20       Impact factor: 2.586

8.  Percutaneous pinning for non-comminuted extra-articular fractures of distal radius.

Authors:  Abhishek K Das; Nandkumar Sundaram; Thiruvengita G Prasad; Suresh K Thanhavelu
Journal:  Indian J Orthop       Date:  2011-09       Impact factor: 1.251

9.  Distal radius fractures: Minimally invasive plate osteosynthesis with dorsal bicolumnar locking plates fixation.

Authors:  Alvin Chao-Yu Chen; Ying-Chao Chou; Chun-Ying Cheng
Journal:  Indian J Orthop       Date:  2017 Jan-Feb       Impact factor: 1.251

10.  Prospective Randomized Study Comparing the External Fixator and Volar Locking Plate in Intraarticular Distal Radius Fractures: Which Is Better?

Authors:  Aryan Sharma; Subodh Pathak; Harinder Sandhu; Priyank Bagtharia; Naveen Kumar; Rajdeep S Bajwa; Vineet Pruthi; Jasneet S Chawla
Journal:  Cureus       Date:  2020-02-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.