Literature DB >> 22038707

Integration of microchip electrophoresis with electrochemical detection using an epoxy-based molding method to embed multiple electrode materials.

Alicia S Johnson1, Asmira Selimovic, R Scott Martin.   

Abstract

This paper describes the use of epoxy-encapsulated electrodes to integrate microchip-based electrophoresis with electrochemical detection. Devices with various electrode combinations can easily be developed. This includes a palladium decoupler with a downstream working electrode material of either gold, mercury/gold, platinum, glassy carbon, or a carbon fiber bundle. Additional device components such as the platinum wires for the electrophoresis separation and the counter electrode for detection can also be integrated into the epoxy base. The effect of the decoupler configuration was studied in terms of the separation performance, detector noise, and the ability to analyze samples of a high ionic strength. The ability of both glassy carbon and carbon fiber bundle electrodes to analyze a complex mixture was demonstrated. It was also shown that a PDMS-based valving microchip can be used along with the epoxy-embedded electrodes to integrate microdialysis sampling with microchip electrophoresis and electrochemical detection, with the microdialysis tubing also being embedded in the epoxy substrate. This approach enables one to vary the detection electrode material as desired in a manner where the electrodes can be polished and modified as is done with electrochemical flow cells used in liquid chromatography.
Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22038707      PMCID: PMC3314886          DOI: 10.1002/elps.201100433

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  37 in total

1.  Fabrication and evaluation of a carbon-based dual-electrode detector for poly(dimethylsiloxane) electrophoresis chips.

Authors:  A J Gawron; R S Martin; S M Lunte
Journal:  Electrophoresis       Date:  2001-01       Impact factor: 3.535

Review 2.  Recent developments in amperometric detection for microchip capillary electrophoresis.

Authors:  Walter R Vandaveer; Stephanie A Pasas; R Scott Martin; Susan M Lunte
Journal:  Electrophoresis       Date:  2002-11       Impact factor: 3.535

3.  Integration of a carbon microelectrode with a microfabricated palladium decoupler for use in microchip capillary electrophoresis/electrochemistry.

Authors:  Michelle L Kovarik; Michelle W Li; R Scott Martin
Journal:  Electrophoresis       Date:  2005-01       Impact factor: 3.535

4.  Monitoring dopamine in vivo by microdialysis sampling and on-line CE-laser-induced fluorescence.

Authors:  Minshan Shou; Carrie R Ferrario; Kristin N Schultz; Terry E Robinson; Robert T Kennedy
Journal:  Anal Chem       Date:  2006-10-01       Impact factor: 6.986

5.  End-column amperometric detection in capillary electrophoresis: influence of separation-related parameters on the observed half-wave potential for dopamine and catechol.

Authors:  S R Wallenborg; L Nyholm; C E Lunte
Journal:  Anal Chem       Date:  1999-02-01       Impact factor: 6.986

6.  Palladium film decoupler for amperometric detection in electrophoresis chips.

Authors:  D Chen; F L Hsu; D Z Zhan; C Chen
Journal:  Anal Chem       Date:  2001-02-15       Impact factor: 6.986

7.  Use of a corona discharge to selectively pattern a hydrophilic/hydrophobic interface for integrating segmented flow with microchip electrophoresis and electrochemical detection.

Authors:  Laura A Filla; Douglas C Kirkpatrick; R Scott Martin
Journal:  Anal Chem       Date:  2011-06-30       Impact factor: 6.986

8.  Integration of on-chip peristaltic pumps and injection valves with microchip electrophoresis and electrochemical detection.

Authors:  Amanda L Bowen; R Scott Martin
Journal:  Electrophoresis       Date:  2010-08       Impact factor: 3.535

9.  Selective detection of endogenous thiols using microchip-based flow analysis and mercury/gold amalgam microelectrodes.

Authors:  Nicholas G Batz; R Scott Martin
Journal:  Analyst       Date:  2008-10-29       Impact factor: 4.616

10.  Integration of serpentine channels for microchip electrophoresis with a palladium decoupler and electrochemical detection.

Authors:  Amanda L Bowen; R Scott Martin
Journal:  Electrophoresis       Date:  2009-10       Impact factor: 3.535

View more
  17 in total

1.  Integrated hybrid polystyrene-polydimethylsiloxane device for monitoring cellular release with microchip electrophoresis and electrochemical detection.

Authors:  Alicia S Johnson; Benjamin T Mehl; R Scott Martin
Journal:  Anal Methods       Date:  2015-02-07       Impact factor: 2.896

2.  Fabrication and Characterization of All-Polystyrene Microfluidic Devices with Integrated Electrodes and Tubing.

Authors:  Amber M Pentecost; R Scott Martin
Journal:  Anal Methods       Date:  2015-02-27       Impact factor: 2.896

3.  3D printed microfluidic devices with integrated versatile and reusable electrodes.

Authors:  Jayda L Erkal; Asmira Selimovic; Bethany C Gross; Sarah Y Lockwood; Eric L Walton; Stephen McNamara; R Scott Martin; Dana M Spence
Journal:  Lab Chip       Date:  2014-04-25       Impact factor: 6.799

Review 4.  A review of microdialysis coupled to microchip electrophoresis for monitoring biological events.

Authors:  Rachel A Saylor; Susan M Lunte
Journal:  J Chromatogr A       Date:  2015-01-10       Impact factor: 4.759

Review 5.  Advances in microfluidic materials, functions, integration, and applications.

Authors:  Pamela N Nge; Chad I Rogers; Adam T Woolley
Journal:  Chem Rev       Date:  2013-02-14       Impact factor: 60.622

Review 6.  Biological applications of microchip electrophoresis with amperometric detection: in vivo monitoring and cell analysis.

Authors:  Kelci M Schilly; Shamal M Gunawardhana; Manjula B Wijesinghe; Susan M Lunte
Journal:  Anal Bioanal Chem       Date:  2020-04-28       Impact factor: 4.142

7.  Continuous monitoring of adenosine and its metabolites using microdialysis coupled to microchip electrophoresis with amperometric detection.

Authors:  Shamal M Gunawardhana; Susan M Lunte
Journal:  Anal Methods       Date:  2018-07-13       Impact factor: 2.896

8.  Encapsulated electrodes for microchip devices: microarrays and platinized electrodes for signal enhancement.

Authors:  Asmira Selimovic; R Scott Martin
Journal:  Electrophoresis       Date:  2013-07       Impact factor: 3.535

9.  Integration of a graphite/poly(methyl-methacrylate) composite electrode into a poly(methylmethacrylate) substrate for electrochemical detection in microchips.

Authors:  Anne Regel; Susan Lunte
Journal:  Electrophoresis       Date:  2013-07       Impact factor: 3.535

10.  Spectroscopic and electrochemical characterization of nanostructured optically transparent carbon electrodes.

Authors:  Tomás E Benavidez; Carlos D Garcia
Journal:  Electrophoresis       Date:  2013-06-21       Impact factor: 3.535

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.