Literature DB >> 9989376

End-column amperometric detection in capillary electrophoresis: influence of separation-related parameters on the observed half-wave potential for dopamine and catechol.

S R Wallenborg1, L Nyholm, C E Lunte.   

Abstract

Capillary electrophoresis (CE) was coupled to a micro-electrode-based end-column amperometric detector. The influences of separation voltage, CE buffer concentration, and capillary-to-electrode distance on the observed hydrodynamic voltammetry of dopamine and catechol were studied using a separation capillary with an i.d. of 25 microns. It was found that an increased CE voltage, increased buffer concentration, or decreased capillary-to-electrode distance resulted in a positive shift of the observed half-wave potentials for both dopamine and catechol. At a constant separation current of 1.6 microA, the observed half-wave potential was found to increase with applied separation voltage. Furthermore, when experiments were carried out with a platinum quasi-reference electrode instead of a Ag/AgCl reference electrode, similar shifts in half-wave potential were observed. These results indicate that the observed shifts are an effect of the separation voltage rather than the separation current or a change in the reference potential. The characteristics of end-column detection with and without a fracture decoupler were compared. It was found that the effects of separation voltage, CE buffer concentration, and capillary-to-electrode distance were minimized by the use of a decoupling device. The observed half-wave potentials for dopamine and catechol were more positive when a CE capillary without a decoupler was employed compared to when a decoupler was used. Additionally, using the fracture decoupler, the observed half-wave potentials for both dopamine and catechol were approximately the same as when no CE voltage was applied (i.e., when the hydrodynamic voltammograms were recorded under flow injection conditions).

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9989376      PMCID: PMC2519803          DOI: 10.1021/ac980737v

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  12 in total

1.  Integrated Capillary Electrophoresis/Electrochemical Detection with Metal Film Electrodes Directly Deposited onto the Capillary Tip.

Authors:  P D Voegel; W Zhou; R P Baldwin
Journal:  Anal Chem       Date:  1997-03-01       Impact factor: 6.986

2.  A perfluorosulfonated ionomer end-column electrical decoupler for capillary electrophoresis/electrochemical detection.

Authors:  S Park; C E Lunte
Journal:  Anal Chem       Date:  1995-12-01       Impact factor: 6.986

3.  End-column detection for capillary zone electrophoresis.

Authors:  X Huang; R N Zare; S Sloss; A G Ewing
Journal:  Anal Chem       Date:  1991-01-15       Impact factor: 6.986

4.  Cellulose acetate-coated porous polymer joint for capillary zone electrophoresis.

Authors:  C W Whang; I C Chen
Journal:  Anal Chem       Date:  1992-10       Impact factor: 6.986

5.  Rudimentary capillary-electrode alignment for capillary electrophoresis with electrochemical detection.

Authors:  A M Fermier; M L Gostkowski; L A Colón
Journal:  Anal Chem       Date:  1996-05-01       Impact factor: 6.986

6.  Dual-electrode detection for capillary electrophoresis/electrochemistry.

Authors:  M Zhong; J Zhou; S M Lunte; G Zhao; D M Giolando; J R Kirchhoff
Journal:  Anal Chem       Date:  1996-01-01       Impact factor: 6.986

7.  Amperometric detection of catechols in capillary zone electrophoresis with normal and micellar solutions.

Authors:  R A Wallingford; A G Ewing
Journal:  Anal Chem       Date:  1988-02-01       Impact factor: 6.986

8.  Capillary zone electrophoresis with electrochemical detection.

Authors:  R A Wallingford; A G Ewing
Journal:  Anal Chem       Date:  1987-07-15       Impact factor: 6.986

9.  Continuous in vivo monitoring of amino acid neurotransmitters by microdialysis sampling with on-line derivatization and capillary electrophoresis separation.

Authors:  S Y Zhou; H Zuo; J F Stobaugh; C E Lunte; S M Lunte
Journal:  Anal Chem       Date:  1995-02-01       Impact factor: 6.986

10.  Optimization of the separation and detection of the enantiomers of isoproterenol in microdialysis samples by cyclodextrin-modified capillary electrophoresis using electrochemical detection.

Authors:  M E Hadwiger; S R Torchia; S Park; M E Biggin; C E Lunte
Journal:  J Chromatogr B Biomed Appl       Date:  1996-06-07
View more
  6 in total

1.  Integration of microchip electrophoresis with electrochemical detection using an epoxy-based molding method to embed multiple electrode materials.

Authors:  Alicia S Johnson; Asmira Selimovic; R Scott Martin
Journal:  Electrophoresis       Date:  2011-10-31       Impact factor: 3.535

2.  In-channel amperometric detection for microchip electrophoresis using a wireless isolated potentiostat.

Authors:  Dulan B Gunasekara; Matthew K Hulvey; Susan M Lunte
Journal:  Electrophoresis       Date:  2011-03-16       Impact factor: 3.535

3.  Non-enzymatic electrochemical sensing of dopamine from COVID-19 quarantine person.

Authors:  Tayyaba Masood; Muhammad Asad; Sara Riaz; Naeem Akhtar; Akhtar Hayat; Mohamed A Shenashen; Mohammed M Rahman
Journal:  Mater Chem Phys       Date:  2022-06-23       Impact factor: 4.778

4.  Simple, rapid, and visual electrochemiluminescence sensor for on-site catechol analysis.

Authors:  Suhua Chen; Yuanyuan Lei; Junrong Xu; Yun Yang; Yiying Dong; Yanmei Li; Haomin Yi; Yilong Liao; Liyin Chen; Yi Xiao
Journal:  RSC Adv       Date:  2022-06-13       Impact factor: 4.036

5.  A parallel dual-electrode detector for capillary electrophoresis.

Authors:  Megan K Dorris; Eric W Crick; Craig E Lunte
Journal:  Electrophoresis       Date:  2012-09       Impact factor: 3.535

6.  Effects of heterogeneous electron-transfer rate on the resolution of electrophoretic separations based on microfluidics with end-column electrochemical detection.

Authors:  Joseph Wang; Baomin Tian; Madhu Prakash Chatrathi; Alberto Escarpa; Martin Pumera
Journal:  Electrophoresis       Date:  2009-10       Impact factor: 3.535

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.