Literature DB >> 22026627

Left ventricular assist device-related infections: past, present and future.

Sanjay Maniar1, Sreekanth Kondareddy, Veli K Topkara.   

Abstract

Over the last decade, left ventricular assist device (LVAD) implantation has emerged as an alternative treatment strategy in patients with advanced heart failure irrespective of their transplant eligibility. However, success and applicability of this therapy is largely limited by high complication rates associated with these devices. Although superior outcomes have been achieved with the second-generation continuous-flow LVADs, device-related infections continue to be a prevalent complication in this patient population and contribute significantly to the financial burden of this therapy due to an increased need for hospitalizations and surgical interventions. Patient selection, device design and LVAD-induced immune system dysfunction appear to be major risk factors for the development of device-related infections. Improvements in device design and better patient selection strategies, particularly with respect to identifying individuals with genetic susceptibility to device-related infections, may further reduce this prevalent complication and improve outcomes in patients with advanced heart failure.

Entities:  

Mesh:

Year:  2011        PMID: 22026627      PMCID: PMC3205433          DOI: 10.1586/erd.11.36

Source DB:  PubMed          Journal:  Expert Rev Med Devices        ISSN: 1743-4440            Impact factor:   3.166


  49 in total

1.  Cellular immunity impaired among patients on left ventricular assist device for 6 months.

Authors:  Pam M Kimball; Maureen Flattery; Felecia McDougan; Vigneshwar Kasirajan
Journal:  Ann Thorac Surg       Date:  2008-05       Impact factor: 4.330

2.  Effect of body mass index and device type on infection in left ventricular assist device support beyond 30 days.

Authors:  Stanley I Martin; Linda Wellington; Kurt B Stevenson; Julie E Mangino; Chittoor B Sai-Sudhakar; Michael S Firstenberg; Danielle Blais; Benjamin C Sun
Journal:  Interact Cardiovasc Thorac Surg       Date:  2010-04-13

3.  Infection after implantation of pulsatile mechanical circulatory support devices.

Authors:  William L Holman; James K Kirklin; David C Naftel; Robert L Kormos; Patricia Desvign-Nickens; Margarita T Camacho; Deborah D Ascheim
Journal:  J Thorac Cardiovasc Surg       Date:  2010-04-03       Impact factor: 5.209

4.  Use of a continuous-flow device in patients awaiting heart transplantation.

Authors:  Leslie W Miller; Francis D Pagani; Stuart D Russell; Ranjit John; Andrew J Boyle; Keith D Aaronson; John V Conte; Yoshifumi Naka; Donna Mancini; Reynolds M Delgado; Thomas E MacGillivray; David J Farrar; O H Frazier
Journal:  N Engl J Med       Date:  2007-08-30       Impact factor: 91.245

5.  Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device.

Authors:  Francis D Pagani; Leslie W Miller; Stuart D Russell; Keith D Aaronson; Ranjit John; Andrew J Boyle; John V Conte; Roberta C Bogaev; Thomas E MacGillivray; Yoshifumi Naka; Donna Mancini; H Todd Massey; Leway Chen; Charles T Klodell; Juan M Aranda; Nader Moazami; Gregory A Ewald; David J Farrar; O Howard Frazier
Journal:  J Am Coll Cardiol       Date:  2009-07-21       Impact factor: 24.094

6.  Obesity and left ventricular assist device driveline exit site infection.

Authors:  Ashley L Raymond; Abdallah G Kfoury; Corey J Bishop; Erin S Davis; Kimberly M Goebel; Sandi Stoker; Craig H Selzman; Stephen E Clayson; Hildegard Smith; Cris G Cowley; Rami Alharethi; Deborah Budge; Bruce B Reid
Journal:  ASAIO J       Date:  2010 Jan-Feb       Impact factor: 2.872

7.  Effect of left ventricular assist device infection on post-transplant outcomes.

Authors:  Allison R Schulman; Timothy P Martens; Mark J Russo; Paul J Christos; Rachel J Gordon; Franklin D Lowy; Mehmet C Oz; Yoshifumi Naka
Journal:  J Heart Lung Transplant       Date:  2009-03       Impact factor: 10.247

8.  Evaluation of risk indices in continuous-flow left ventricular assist device patients.

Authors:  Justin M Schaffer; Jeremiah G Allen; Eric S Weiss; Nishant D Patel; Stuart D Russell; Ashish S Shah; John V Conte
Journal:  Ann Thorac Surg       Date:  2009-12       Impact factor: 4.330

9.  Advanced heart failure treated with continuous-flow left ventricular assist device.

Authors:  Mark S Slaughter; Joseph G Rogers; Carmelo A Milano; Stuart D Russell; John V Conte; David Feldman; Benjamin Sun; Antone J Tatooles; Reynolds M Delgado; James W Long; Thomas C Wozniak; Waqas Ghumman; David J Farrar; O Howard Frazier
Journal:  N Engl J Med       Date:  2009-11-17       Impact factor: 91.245

10.  Late-onset driveline infections: the Achilles' heel of prolonged left ventricular assist device support.

Authors:  Andreas Zierer; Spencer J Melby; Rochus K Voeller; Tracey J Guthrie; Gregory A Ewald; Kim Shelton; Michael K Pasque; Marc R Moon; Ralph J Damiano; Nader Moazami
Journal:  Ann Thorac Surg       Date:  2007-08       Impact factor: 4.330

View more
  16 in total

1.  Preoperative patient optimization for mechanical circulatory support.

Authors:  Brian A Houston; Stuart D Russell
Journal:  Ann Cardiothorac Surg       Date:  2014-11

Review 2.  Impact of adverse events on ventricular assist device outcomes.

Authors:  Aleksandar Adzic; Snehal R Patel; Simon Maybaum
Journal:  Curr Heart Fail Rep       Date:  2013-03

3.  Exercise guidelines for inpatients following ventricular assist device placement: a systematic review of the literature.

Authors:  Rachel Scheiderer; Courtney Belden; Darla Schwab; Casey Haney; Jaime Paz
Journal:  Cardiopulm Phys Ther J       Date:  2013-06

4.  Delayed febrile response with bloodstream infections in patients with continuous-flow left ventricular assist devices.

Authors:  Christopher A Wrobel; Mark H Drazner; Colby R Ayers; David D Pham; Ricardo M La Hoz; Justin L Grodin; Sonia Garg; Pradeep P A Mammen; Robert M Morlend; Faris Araj; Alpesh A Amin; William K Cornwell; Jennifer T Thibodeau
Journal:  J Investig Med       Date:  2019-01-29       Impact factor: 2.895

5.  Disseminated Streptococcus pneumoniae infection involving a ventricular assist device.

Authors:  J S Reeves; N Rajagopalan; M A Huaman
Journal:  Transpl Infect Dis       Date:  2015-07-14       Impact factor: 2.228

Review 6.  Role of gallium SPECT-CT in the diagnosis of left ventricular assist device infections.

Authors:  Dana T Levy; Grace Y Minamoto; Raphaella Da Silva; Yoram A Puius; Naomi Peck; Daniel Goldstein; David D'Alessandro; Victoria A Muggia
Journal:  ASAIO J       Date:  2015 Jan-Feb       Impact factor: 2.872

Review 7.  Endocarditis in left ventricular assist device.

Authors:  Braghadheeswar Thyagarajan; Monisha Priyadarshini Kumar; Rutuja R Sikachi; Abhinav Agrawal
Journal:  Intractable Rare Dis Res       Date:  2016-08

Review 8.  Wound care of the driveline exit site in patients with a ventricular assist device: A systematic review.

Authors:  Zeliha Özdemir; Sevilay Şenol Çelik
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2018-04-30       Impact factor: 0.332

9.  Suspected involvement of EPTFE membrane in sterile intrathoracic abscess and pericardial empyema in a multi-allergic LVAD recipient: a case report.

Authors:  A Kornberger; V Walter; M Khalil; P Therapidis; B Assmus; A Moritz; A Beiras-Fernandez; U A Stock
Journal:  J Cardiothorac Surg       Date:  2015-07-17       Impact factor: 1.637

Review 10.  Durable Mechanical Circulatory Support versus Organ Transplantation: Past, Present, and Future.

Authors:  Jatin Anand; Steve K Singh; David G Antoun; William E Cohn; O H Bud Frazier; Hari R Mallidi
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.