Literature DB >> 20388700

Effect of body mass index and device type on infection in left ventricular assist device support beyond 30 days.

Stanley I Martin1, Linda Wellington, Kurt B Stevenson, Julie E Mangino, Chittoor B Sai-Sudhakar, Michael S Firstenberg, Danielle Blais, Benjamin C Sun.   

Abstract

Infection as a complication of long-term left ventricular assist device (LVAD) support leads to significant morbidity and mortality. Obesity, a possible risk factor for other postoperative cardiovascular surgical site infections, is an increasingly prevalent condition among recipients of LVAD devices. We retrospectively analyzed 145 LVADs that remained in place beyond 30 days over a nine-year period at a single medical institution. Statistical analysis was carried out using univariate and multivariable logistic regression and chi(2)-testing where indicated. Body mass index (BMI) had no effect on the incidence of infectious outcomes regardless of age, gender, underlying pathogen or device type. This included the morbidly obese population as well (BMI >or=40). Independent of BMI, device type did have an effect, with the HeartMate XVE increasing the risk for infections [odds ratio (OR) 4.3 with 95% confidence interval (CI) 2.1-8.8, P=0.0001] and the HeartMate II reducing the risk (OR 0.21 with 95% CI 0.09-0.50, P=0.0001). The risk for infection after LVAD placement for long-term support is likely to be a multi-factorial phenomenon. BMI, including morbid obesity, does not appear to be a statistically significant relevant factor in determining that risk. Device type may have an effect, however, on risk of infection in long-term support.

Entities:  

Mesh:

Year:  2010        PMID: 20388700     DOI: 10.1510/icvts.2009.227801

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  6 in total

1.  Body mass index and infectious disease mortality in midlife in a cohort of 2.3 million adolescents.

Authors:  G Twig; N Geva; H Levine; E Derazne; N Goldberger; Z Haklai; A Leiba; J D Kark
Journal:  Int J Obes (Lond)       Date:  2017-10-30       Impact factor: 5.095

2.  Readmission due to driveline infection can be predicted by new score by using serum albumin and body mass index during long-term left ventricular assist device support.

Authors:  Teruhiko Imamura; Koichiro Kinugawa; Daisuke Nitta; Toshiro Inaba; Hisataka Maki; Masaru Hatano; Osamu Kinoshita; Kan Nawata; Shunei Kyo; Minoru Ono
Journal:  J Artif Organs       Date:  2015-01-21       Impact factor: 1.731

3.  Infectious Complications of Mechanical Circulatory Support (MCS) Devices.

Authors:  Stanley I Martin
Journal:  Curr Infect Dis Rep       Date:  2013-09-29       Impact factor: 3.725

Review 4.  Left ventricular assist device-related infections: past, present and future.

Authors:  Sanjay Maniar; Sreekanth Kondareddy; Veli K Topkara
Journal:  Expert Rev Med Devices       Date:  2011-09       Impact factor: 3.166

5.  Gender differences in risk of bloodstream and surgical site infections.

Authors:  Bevin Cohen; Yoon Jeong Choi; Sandra Hyman; E Yoko Furuya; Matthew Neidell; Elaine Larson
Journal:  J Gen Intern Med       Date:  2013-04-19       Impact factor: 5.128

6.  Current status of mechanical circulatory support: a systematic review.

Authors:  Kyriakos Spiliopoulos; Gregory Giamouzis; George Karayannis; Dimos Karangelis; Stelios Koutsias; Andreas Kalogeropoulos; Vasiliki Georgiopoulou; John Skoularigis; Javed Butler; Filippos Triposkiadis
Journal:  Cardiol Res Pract       Date:  2012-08-26       Impact factor: 1.866

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.