Literature DB >> 22015316

Inverse dynamic analysis of the biomechanics of the thumb while pipetting: a case study.

John Z Wu1, Erik W Sinsel, Daniel S Gloekler, Bryan M Wimer, Kristin D Zhao, Kai-Nan An, Frank L Buczek.   

Abstract

Thumb-push manual pipettes are commonly used tools in many medical, biological, and chemical laboratories. Epidemiological studies indicate that the use of thumb-push mechanical pipettes is associated with musculoskeletal disorders in the hand. The goal of the current study was to evaluate the kinematics and joint loading of the thumb during pipetting. The time-histories of joint angles and the interface contact force between the thumb and plunger during the pipetting action were determined experimentally, and the joint loadings and joint power in the thumb were calculated via an inverse dynamic approach. The moment, power, and energy absorption in each joint of the thumb during the extraction and dispensing actions were analyzed. The results indicate that the majority of the power is generated in the interphalangeal (IP) and carpometacarpal (CMC) joints for the pipetting action. The analysis method and results in the current study will be helpful in exploring the mechanism for musculoskeletal injuries of the hand associated with pipetting, providing a preliminary foundation for ergonomic design of the pipette. Published by Elsevier Ltd.

Entities:  

Mesh:

Year:  2011        PMID: 22015316     DOI: 10.1016/j.medengphy.2011.09.012

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  6 in total

1.  Analysis of the Constraint Joint Loading in the Thumb During Pipetting.

Authors:  John Z Wu; Erik W Sinsel; Kristin D Zhao; Kai-Nan An; Frank L Buczek
Journal:  J Biomech Eng       Date:  2015-06-09       Impact factor: 2.097

2.  The musculoskeletal loading profile of the thumb during pipetting based on tendon displacement.

Authors:  John Z Wu; Erik W Sinsel; Justin F Shroyer; Daniel E Welcome; Kristin D Zhao; Kai-Nan An; Frank L Buczek
Journal:  Med Eng Phys       Date:  2013-09-06       Impact factor: 2.242

3.  Analysis of the musculoskeletal loading of the thumb during pipetting--a pilot study.

Authors:  John Z Wu; Erik W Sinsel; Justin F Shroyer; Christopher M Warren; Daniel E Welcome; Kristin D Zhao; Kai-Nan An; Frank L Buczek
Journal:  J Biomech       Date:  2013-11-15       Impact factor: 2.712

4.  Automated pressure map segmentation for quantifying phalangeal kinetics during cylindrical gripping.

Authors:  Erik W Sinsel; Daniel S Gloekler; Bryan M Wimer; Christopher M Warren; John Z Wu; Frank L Buczek
Journal:  Med Eng Phys       Date:  2015-12-18       Impact factor: 2.242

5.  The Status of Musculoskeletal Disorders and Its Influence on the Working Ability of Oil Workers in Xinjiang, China.

Authors:  Hua Ge; Xuemei Sun; Jiwen Liu; Chen Zhang
Journal:  Int J Environ Res Public Health       Date:  2018-04-24       Impact factor: 3.390

6.  Musculoskeletal Modeling and Inverse Dynamic Analysis of Precision Grip in the Japanese Macaque.

Authors:  Tsuyoshi Saito; Naomichi Ogihara; Tomohiko Takei; Kazuhiko Seki
Journal:  Front Syst Neurosci       Date:  2021-12-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.