Automated pressure map segmentation for quantifying phalangeal kinetics during cylindrical gripping.

Erik W Sinsel1, Daniel S Gloekler2, Bryan M Wimer3, Christopher M Warren3, John Z Wu3, Frank L Buczek4.   

Abstract

Inverse dynamics models used to investigate musculoskeletal disorders associated with handle gripping require accurate phalangeal kinetics. Cylindrical handles wrapped with pressure film grids have been used in studies of gripping kinetics. We present a method fusing six degree-of-freedom hand kinematics and a kinematic calibration of a cylinder-wrapped pressure film. Phalanges are modeled as conic frusta and projected onto the pressure grid, automatically segmenting the pressure map into regions of interest (ROIs). To demonstrate the method, segmented pressure maps are presented from two subjects with substantially different hand length and body mass, gripping cylinders 50 and 70 mm in diameter. For each ROI, surface-normal force vectors were summed to create a reaction force vector and center of pressure location. Phalangeal force magnitudes for a data sample were similar to that reported in previous studies. To evaluate our method, a surrogate was designed for each handle such that when modeled as a phalanx it would generate a ROI around the cells under its supports; the classification F-score was above 0.95 for both handles. Both the human subject results and the surrogate evaluation suggest that the approach can be used to automatically segment the pressure map for quantifying phalangeal kinetics of the fingers during cylindrical gripping. Published by Elsevier Ltd.

Entities:  

Keywords:  Cylindrical handle; Grip; Hand; Pressure distribution; Pressure film

Mesh:

Year:  2015        PMID: 26709291      PMCID: PMC4830423          DOI: 10.1016/j.medengphy.2015.11.004

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  30 in total

Review 1.  A survey of medical image registration.

Authors:  J B Maintz; M A Viergever
Journal:  Med Image Anal       Date:  1998-03       Impact factor: 8.545

2.  Measurement of finger joint angles and maximum finger forces during cylinder grip activity.

Authors:  J W Lee; K Rim
Journal:  J Biomed Eng       Date:  1991-03

3.  Anthropometric data for describing the kinematics of the human hand.

Authors:  B Buchholz; T J Armstrong; S A Goldstein
Journal:  Ergonomics       Date:  1992-03       Impact factor: 2.778

4.  A framework for evaluating image segmentation algorithms.

Authors:  Jayaram K Udupa; Vicki R Leblanc; Ying Zhuge; Celina Imielinska; Hilary Schmidt; Leanne M Currie; Bruce E Hirsch; James Woodburn
Journal:  Comput Med Imaging Graph       Date:  2006-03       Impact factor: 4.790

5.  An ellipsoidal representation of human hand anthropometry.

Authors:  B Buchholz; T J Armstrong
Journal:  Hum Factors       Date:  1991-08       Impact factor: 2.888

6.  Variation of finger forces in maximal isometric grasp tests on a range of cylinder diameters.

Authors:  A A Amis
Journal:  J Biomed Eng       Date:  1987-10

7.  Analysis of hand forces in health and disease during maximum isometric grasping of cylinders.

Authors:  S Radhakrishnan; M Nagaravindra
Journal:  Med Biol Eng Comput       Date:  1993-07       Impact factor: 2.602

8.  Grip force vectors for varying handle diameters and hand sizes.

Authors:  Cally S Edgren; Robert G Radwin; Curtis B Irwin
Journal:  Hum Factors       Date:  2004       Impact factor: 2.888

9.  Effects of noise, image resolution, and ROI definition on the accuracy of standard uptake values: a simulation study.

Authors:  Ronald Boellaard; Nanda C Krak; Otto S Hoekstra; Adriaan A Lammertsma
Journal:  J Nucl Med       Date:  2004-09       Impact factor: 10.057

10.  Investigation of grip force, normal force, contact area, hand size, and handle size for cylindrical handles.

Authors:  Na Jin Seo; Thomas J Armstrong
Journal:  Hum Factors       Date:  2008-10       Impact factor: 3.598

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.