Literature DB >> 22012485

[Implant materials for the internal fixation of midfacial fractures].

B A Stuck1, T Heller.   

Abstract

The material used for osteosynthesis plays a crucial role in the management of facial fractures. Plates need to be flexible enough to be bent and should not be palpable through the skin, while ensuring stable fixation und adequate biocompatibility. Although stainless steel was initially the material of choice, titanium has become the standard material due to its superior biocompatibility. While the explantation of titanium plates and screws appears unnecessary in general, it should be considered in cases of dislocation, cosmetic concerns, pain and infection. Due to their limited initial stability and a potential increase in local complications, resorbable materials based on polymeric lactose are used with caution in midfacial fractures in adults. Our own retrospective study comparing the postoperative complications after fixation of lateral midfacial fractures with titanium and resorbable systems demonstrated a low complication rate for both systems (7-8%) and no statistically significant difference between the two. The appropriate material for fixation should be selected based on the localization and severity of the fracture, the experience of the surgeon as well as on the age and overall condition of the patient.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22012485     DOI: 10.1007/s00106-011-2386-9

Source DB:  PubMed          Journal:  HNO        ISSN: 0017-6192            Impact factor:   1.284


  27 in total

Review 1.  The future of biodegradable osteosyntheses.

Authors:  F W Cordewener; J P Schmitz
Journal:  Tissue Eng       Date:  2000-08

2.  Le Fort I miniplate osteosynthesis: a randomized, prospective study comparing resorbable PLLA/PGA with titanium.

Authors:  S E Norholt; T K Pedersen; J Jensen
Journal:  Int J Oral Maxillofac Surg       Date:  2004-04       Impact factor: 2.789

3.  The removal of plates and screws after Le Fort I osteotomy.

Authors:  B L Schmidt; D H Perrott; D Mahan; G Kearns
Journal:  J Oral Maxillofac Surg       Date:  1998-02       Impact factor: 1.895

4.  Fracture reduction using a biodegradable material, polylactic acid.

Authors:  D E Cutright; E E Hunsuck; J D Beasley
Journal:  J Oral Surg       Date:  1971-06

5.  The effect of rigid internal fixation on cranial growth.

Authors:  J I Resnick; B M Kinney; H K Kawamoto
Journal:  Ann Plast Surg       Date:  1990-11       Impact factor: 1.539

6.  Metal release from plates used in jaw fracture treatment. A pilot study.

Authors:  L E Moberg; A Nordenram; O Kjellman
Journal:  Int J Oral Maxillofac Surg       Date:  1989-10       Impact factor: 2.789

7.  Significance of biodegradable implants in case of midfacial fractures.

Authors:  J Hoffmann; D Troitzsch; D Gülicher; C Adam; S Reinert
Journal:  Biomed Tech (Berl)       Date:  2002       Impact factor: 1.411

8.  Five-year experience comparing resorbable to titanium miniplate osteosynthesis in cleft lip and palate orthognathic surgery.

Authors:  Constantin A Landes; Alexander Ballon
Journal:  Cleft Palate Craniofac J       Date:  2006-01

9.  The fate of plates and screws after facial fracture reconstruction.

Authors:  T J Francel; B C Birely; P R Ringelman; P N Manson
Journal:  Plast Reconstr Surg       Date:  1992-10       Impact factor: 4.730

10.  Long-term effects of rigid fixation on the growing craniomaxillofacial skeleton.

Authors:  M A Marschall; S A Chidyllo; A A Figueroa; M Cohen
Journal:  J Craniofac Surg       Date:  1991-07       Impact factor: 1.046

View more
  1 in total

1.  [Orbitocutaneous fistula after orbital reconstruction].

Authors:  R Huelse; A Freuschle; K Hörmann; B A Stuck
Journal:  HNO       Date:  2013-04       Impact factor: 1.284

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.