Literature DB >> 22007695

Contribution of solid fuel, gas combustion, or tobacco smoke to indoor air pollutant concentrations in Irish and Scottish homes.

S Semple1, C Garden, M Coggins, K S Galea, P Whelan, H Cowie, A Sánchez-Jiménez, P S Thorne, J F Hurley, J G Ayres.   

Abstract

UNLABELLED: There are limited data describing pollutant levels inside homes that burn solid fuel within developed country settings with most studies describing test conditions or the effect of interventions. This study recruited homes in Ireland and Scotland where open combustion processes take place. Open combustion was classified as coal, peat, or wood fuel burning, use of a gas cooker or stove, or where there is at least one resident smoker. Twenty-four-hour data on airborne concentrations of particulate matter<2.5 μm in size (PM2.5), carbon monoxide (CO), endotoxin in inhalable dust and carbon dioxide (CO2), together with 2-3 week averaged concentrations of nitrogen dioxide (NO2) were collected in 100 houses during the winter and spring of 2009-2010. The geometric mean of the 24-h time-weighted-average (TWA) PM2.5 concentration was highest in homes with resident smokers (99 μg/m3--much higher than the WHO 24-h guidance value of 25 μg/m3). Lower geometric mean 24-h TWA levels were found in homes that burned coal (7 μg/m3) or wood (6 μg/m3) and in homes with gas cookers (7 μg/m3). In peat-burning homes, the average 24-h PM2.5 level recorded was 11 μg/m3. Airborne endotoxin, CO, CO2, and NO2 concentrations were generally within indoor air quality guidance levels. PRACTICAL IMPLICATIONS: Little is known about indoor air quality (IAQ) in homes that burn solid or fossil-derived fuels in economically developed countries. Recent legislative changes have moved to improve IAQ at work and in enclosed public places, but there remains a real need to begin the process of quantifying the health burden that arises from indoor air pollution within domestic environments. This study demonstrates that homes in Scotland and Ireland that burn solid fuels or gas for heating and cooking have concentrations of air pollutants generally within guideline levels. Homes where combustion of cigarettes takes place have much poorer air quality.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22007695      PMCID: PMC3573694          DOI: 10.1111/j.1600-0668.2011.00755.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  50 in total

Review 1.  Meta-analysis of the effect of comprehensive smoke-free legislation on acute coronary events.

Authors:  D F Mackay; M O Irfan; S Haw; J P Pell
Journal:  Heart       Date:  2010-08-23       Impact factor: 5.994

Review 2.  COPD and chronic bronchitis risk of indoor air pollution from solid fuel: a systematic review and meta-analysis.

Authors:  Om P Kurmi; Sean Semple; Padam Simkhada; W Cairns S Smith; Jon G Ayres
Journal:  Thorax       Date:  2010-03       Impact factor: 9.139

3.  Smoke-free legislation and hospitalizations for childhood asthma.

Authors:  Daniel Mackay; Sally Haw; Jon G Ayres; Colin Fischbacher; Jill P Pell
Journal:  N Engl J Med       Date:  2010-09-16       Impact factor: 91.245

4.  Changes in child exposure to environmental tobacco smoke (CHETS) study after implementation of smoke-free legislation in Scotland: national cross sectional survey.

Authors:  Patricia C Akhtar; Dorothy B Currie; Candace E Currie; Sally J Haw
Journal:  BMJ       Date:  2007-09-09

5.  Concentration of indoor particulate matter as a determinant of respiratory health in children.

Authors:  L M Neas; D W Dockery; J H Ware; J D Spengler; B G Ferris; F E Speizer
Journal:  Am J Epidemiol       Date:  1994-06-01       Impact factor: 4.897

Review 6.  The health effects of non-industrial indoor air pollution.

Authors:  Jonathan A Bernstein; Neil Alexis; Hyacinth Bacchus; I Leonard Bernstein; Pat Fritz; Elliot Horner; Ning Li; Stephany Mason; Andre Nel; John Oullette; Kari Reijula; Tina Reponen; James Seltzer; Alisa Smith; Susan M Tarlo
Journal:  J Allergy Clin Immunol       Date:  2007-12-21       Impact factor: 10.793

7.  Assessment of endotoxin levels in the home and current asthma and wheeze in school-age children.

Authors:  D C Rennie; J A Lawson; S P Kirychuk; C Paterson; P J Willson; A Senthilselvan; D W Cockcroft
Journal:  Indoor Air       Date:  2008-08-04       Impact factor: 5.770

8.  Indoor levels of polycyclic aromatic hydrocarbons in homes with or without wood burning for heating.

Authors:  Pernilla Gustafson; Conny Ostman; Gerd Sällsten
Journal:  Environ Sci Technol       Date:  2008-07-15       Impact factor: 9.028

9.  Biomass fuel use and indoor air pollution in homes in Malawi.

Authors:  D G Fullerton; S Semple; F Kalambo; A Suseno; R Malamba; G Henderson; J G Ayres; S B Gordon
Journal:  Occup Environ Med       Date:  2009-08-10       Impact factor: 4.402

10.  The impact of the environment on health by country: a meta-synthesis.

Authors:  Annette Prüss-Ustün; Sophie Bonjour; Carlos Corvalán
Journal:  Environ Health       Date:  2008-02-25       Impact factor: 5.984

View more
  17 in total

1.  Characterizing peak exposure of secondhand smoke using a real-time PM2.5 monitor.

Authors:  Ting Zhang; Steven N Chillrud; Qiang Yang; Masha Pitiranggon; James Ross; Frederica Perera; Junfeng Ji; Avrum Spira; Patrick N Breysse; Charles E Rodes; Rachel Miller; Beizhan Yan
Journal:  Indoor Air       Date:  2019-12-11       Impact factor: 5.770

2.  Effects of indoor coal fine particulate matter on the expression levels of inflammatory factors in ovalbumin-induced mice.

Authors:  Jie Yu; Yin Tang; Jie Xu
Journal:  Toxicol Res (Camb)       Date:  2018-11-01       Impact factor: 3.524

3.  Source attribution of personal exposure to airborne polycyclic aromatic hydrocarbon mixture using concurrent personal, indoor, and outdoor measurements.

Authors:  Hyunok Choi; John Spengler
Journal:  Environ Int       Date:  2013-12-04       Impact factor: 9.621

4.  Particulate matter in the indoor and outdoor air of a gymnasium and a fronton.

Authors:  Célia Alves; Ana I Calvo; Liliana Marques; Amaya Castro; Teresa Nunes; Esther Coz; Roberto Fraile
Journal:  Environ Sci Pollut Res Int       Date:  2014-06-18       Impact factor: 4.223

Review 5.  Indoor fuel exposure and the lung in both developing and developed countries: an update.

Authors:  Akshay Sood
Journal:  Clin Chest Med       Date:  2012-12       Impact factor: 2.878

6.  Coarse particulate matter and airborne endotoxin within wood stove homes.

Authors:  M McNamara; J Thornburg; E Semmens; T Ward; C Noonan
Journal:  Indoor Air       Date:  2013-04-18       Impact factor: 5.770

7.  Clearing the smoke around the TB-HIV syndemic: smoking as a critical issue for TB and HIV treatment and care.

Authors:  A Jackson-Morris; P I Fujiwara; E Pevzner
Journal:  Int J Tuberc Lung Dis       Date:  2015-09       Impact factor: 2.373

8.  The impact of second-hand smoke on nitrogen oxides concentrations in a small interior.

Authors:  Markus Braun; Doris Klingelhöfer; Ruth Müller; David A Groneberg
Journal:  Sci Rep       Date:  2021-06-03       Impact factor: 4.379

9.  Using PM2.5 concentrations to estimate the health burden from solid fuel combustion, with application to Irish and Scottish homes.

Authors:  Karen S Galea; J Fintan Hurley; Hilary Cowie; Amy L Shafrir; Araceli Sánchez Jiménez; Sean Semple; Jon G Ayres; Marie Coggins
Journal:  Environ Health       Date:  2013-06-19       Impact factor: 5.984

10.  A cross sectional analysis of behaviors related to operating gas stoves and pneumonia in U.S. children under the age of 5.

Authors:  Eric S Coker; Ellen Smit; Anna K Harding; John Molitor; Molly L Kile
Journal:  BMC Public Health       Date:  2015-02-04       Impact factor: 3.295

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.