Can CT-based patient-matched instrumentation achieve consistent rotational alignment in knee arthroplasty?

C O Tibesku1, B Innocenti, P Wong, A Salehi, L Labey.   

Abstract

PURPOSE: Long-term success of contemporary total knee replacements relies to a large extent on proper implant alignment. This study was undertaken to test whether specimen-matched cutting blocks based on computed axial tomography (CT) scans could provide accurate rotational alignment of the femoral component.
METHODS: CT scans of five fresh frozen full leg cadaver specimens, equipped with infrared reflective markers, were used to produce a specimen-matched femoral cutting block. Using those blocks, the bone cuts were made to implant a bi-compartmental femoral component. Rotational alignment of the components in the horizontal plane was determined using an optical measurement system and compared with all relevant rotational reference axes identified on the CT scans.
RESULTS: Average rotational alignment for the bi-compartmental component in the horizontal plane was 1.9° (range 0°-6.3°; standard deviation 2.6°). One specimen that showed the highest deviation from the planned alignment also featured a completely degraded medial articular surface.
CONCLUSIONS: The CT-based specimen-matched cutting blocks achieved good rotational alignment accuracy except for one specimen with badly damaged cartilage. In such cases, imaging techniques that visualize the cartilage layer might be more suitable to design cutting blocks, as they will provide a better fit and increased surface support.

Entities:  

Mesh:

Year:  2011        PMID: 22006572     DOI: 10.1007/s00402-011-1406-2

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  11 in total

1.  Accuracy of Individualized Custom Tibial Cutting Guides in UKA.

Authors:  Thomas J Heyse; Joseph D Lipman; Carl W Imhauser; Scott M Tucker; Yogesh Rajak; Geoffrey H Westrich
Journal:  HSS J       Date:  2014-09-09

Review 2.  Bicompartmental knee arthroplasty of the patellofemoral and medial compartments.

Authors:  Emmanuel Thienpont; Andrew Price
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11-25       Impact factor: 4.342

3.  Accuracy of tibial cuts with patient-specific instrumentation is not influenced by the surgeon's level of experience.

Authors:  Alexander Antoniadis; Roland S Camenzind; Michael O Schär; Dario Bergadano; Näder Helmy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-06-05       Impact factor: 4.342

Review 4.  Bicompartmental knee arthroplasty.

Authors:  Luigi Sabatini; Matteo Giachino; Salvatore Risitano; Francesco Atzori
Journal:  Ann Transl Med       Date:  2016-01

5.  [Total knee arthroplasty with the use of patient specific instruments. The VISIONAIRE system].

Authors:  C O Tibesku
Journal:  Orthopade       Date:  2016-04       Impact factor: 1.087

6.  Computerized tomography based "patient specific blocks" improve postoperative mechanical alignment in primary total knee arthroplasty.

Authors:  Raju Vaishya; Vipul Vijay; Vikas P Birla; Amit K Agarwal
Journal:  World J Orthop       Date:  2016-07-18

7.  Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement.

Authors:  Andrea Ensini; Antonio Timoncini; Francesco Cenni; Claudio Belvedere; Francesca Fusai; Alberto Leardini; Sandro Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-24       Impact factor: 4.342

8.  CT-based TruMatch® Personal Solutions for knee replacement Surgery … Does it really match?

Authors:  Amila N Silva; You Wei Adriel Tay; Sharon Tan Si Heng; Siang Shen Leon Foo; Hee Nee Pang; Darren Tay Keng Jin; Ngai Nung Lo; Seng Jin Yeo
Journal:  J Orthop       Date:  2019-11-27

9.  MRI-based or CT-based patient-specific instrumentation in Total knee Arthroplasty: How do the two systems compare?

Authors:  Dong-Geun Kang; Kang-Il Kim; Jung-Kwon Bae
Journal:  Arthroplasty       Date:  2020-01-14

10.  The Effect of Femoral Cutting Guide Design Improvements for Patient-Specific Instruments.

Authors:  Oh-Ryong Kwon; Kyoung-Tak Kang; Juhyun Son; Yun-Jin Choi; Dong-Suk Suh; Yong-Gon Koh
Journal:  Biomed Res Int       Date:  2015-12-31       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.