Literature DB >> 2199453

Primary migration of fully-threaded acetabular prostheses. A roentgen stereophotogrammetric analysis.

F Snorrason1, J Kärrholm.   

Abstract

We investigated the fixation of fully-threaded cementless acetabular prostheses in 20 patients with osteoarthritis, measuring the migration of the cup using roentgen stereophotogrammetric analysis (RSA). All the cups migrated proximally, 13 moved laterally or medially, and nine moved anteriorly or posteriorly in the first two postoperative years, the average migration being 1.1 to 1.4 mm in either direction. Rotatory movements of up to 5.7 degrees were found in nine of the 13 hips where this analysis could be performed. Movements of cobalt-chrome (12) and titanium alloy (8) cups did not differ significantly. Seventeen of the 20 patients had some pain two years after the operation. The migration of the prostheses indicates that 'osseointegration' had not occurred. The combination of this with persistent pain suggests that the long-term results will be unfavourable.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2199453

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  9 in total

1.  Modes of failure of a threaded acetabular cup : a radiographic study with EBRA of 42 revised cups.

Authors:  Thomas Ilchmann; Severin Neher; Franz Maurer; Kuno Weise
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

2.  [Poor results in 183 threaded acetabular cups at a mean 7 years follow-up].

Authors:  P Lecestre; P Poilbout; A Dambreville; D Vial
Journal:  Eur J Orthop Surg Traumatol       Date:  1995-12

3.  [Long-term results of 2 uncemented acetabular cup components in total hip prosthesis].

Authors:  D Schmitt; O Bigard; F Bresler; D Molé; P Bernard
Journal:  Int Orthop       Date:  1993-12       Impact factor: 3.075

4.  [Acetabulum without cement. Short-term results of a series of 112 threaded cups].

Authors:  F Gouin; F Fechoz; N Passuti; J Sentucq-Rigal; O Bertrand; J V Bainvel
Journal:  Int Orthop       Date:  1993       Impact factor: 3.075

5.  Intermittent Parathyroid Hormone Enhances Cancellous Osseointegration of a Novel Murine Tibial Implant.

Authors:  Xu Yang; Benjamin F Ricciardi; Aleksey Dvorzhinskiy; Caroline Brial; Zachary Lane; Samrath Bhimani; Jayme C Burket; Bin Hu; Alexander M Sarkisian; F Patrick Ross; Marjolein C H van der Meulen; Mathias P G Bostrom
Journal:  J Bone Joint Surg Am       Date:  2015-07-01       Impact factor: 5.284

6.  Fixation of hydroxyapatite-coated revision implants is improved by the surgical technique of cracking the sclerotic bone rim.

Authors:  Brian Elmengaard; Joan E Bechtold; Xinqian Chen; Kjeld Søballe
Journal:  J Orthop Res       Date:  2009-08       Impact factor: 3.494

7.  Second-generation uncemented total hip arthroplasty: a minimum 20-year follow-up.

Authors:  Jeffrey R McLaughlin; Kyla R Lee; Mary Ann Johnson
Journal:  Bone Jt Open       Date:  2021-01-13

Review 8.  Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survivalstudies.

Authors:  Bart G Pijls; Marc J Nieuwenhuijse; Marta Fiocco; Josepha Wm Plevier; Saskia Middeldorp; Rob Ghh Nelissen; Edward R Valstar
Journal:  Acta Orthop       Date:  2012-11-05       Impact factor: 3.717

9.  Radiostereometric analysis of early implant migration - a valuable tool to ensure proper introduction of new implants.

Authors:  Johan Kärrholm
Journal:  Acta Orthop       Date:  2012-11-05       Impact factor: 3.717

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.