Literature DB >> 21990462

Treatment of two blood blister-like aneurysms with flow diverter stenting.

Arturo Consoli1, Sergio Nappini, Leonardo Renieri, Nicola Limbucci, Fabrizio Ricciardi, Salvatore Mangiafico.   

Abstract

PURPOSE: Neurosurgical and endovascular treatment of fragile and recurrent aneurysms of the non-branching portion of the internal carotid artery, known as blister-like aneurysms, is challenging. The aim of this paper is to describe two cases of ruptured blister-like aneurysms of the internal carotid artery and of the vertebral artery at the origin of the postero-inferior cerebellar artery, which were both treated with flow diverter (FD) stents.
METHODS: Two patients with a sub-arachnoid hemorrhage secondary to the rupture of a blister-like aneurysm were treated with a Pipeline (ev3, Irvine, California, USA) stent. Digital subtraction angiography and clinical follow-up were carried out.
RESULTS: Both patients treated with FD stents had an excellent clinical (modified Rankin Scale, mRS 0) and angiographic outcome. In both cases the aneurysms were completely excluded after 6 months.
CONCLUSIONS: Although the use of this endovascular approach is still debated because of poor experience and pharmacological limitations, FD stents may represent a valid alternative approach for treatment of this aneurysm subtype.

Entities:  

Mesh:

Year:  2011        PMID: 21990462     DOI: 10.1136/jnis.2010.004572

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  16 in total

1.  Flow-diverter stenting of post-traumatic bilateral anterior cerebral artery pseudoaneurysm: A case report.

Authors:  Andrea Giorgianni; Carlo Pellegrino; Renzo Minotto; Anna Mercuri; Lara Frattini; Fabio Baruzzi; Luca Valvassori
Journal:  Interv Neuroradiol       Date:  2015-02       Impact factor: 1.610

2.  Endovascular treatment of intracranial aneurysms with flow-diverter stents: preliminary single-centre experience.

Authors:  Emanuele Malatesta; Nunzio Paolo Nuzzi; Ignazio Divenuto; Rita Fossaceca; Mariangela Lombardi; Paolo Cerini; Giuseppe Guzzardi; Alessandro Stecco; Cosma Andreula; Alessandro Carriero
Journal:  Radiol Med       Date:  2013-06-26       Impact factor: 3.469

3.  Pipeline embolization device retraction and foreshortening after internal carotid artery blister aneurysm treatment.

Authors:  Jeremy J Heit; Nicholas A Telischak; Huy M Do; Robert L Dodd; Gary K Steinberg; Michael P Marks
Journal:  Interv Neuroradiol       Date:  2017-07-31       Impact factor: 1.610

Review 4.  Treatment of ruptured blood blister aneurysms using primary flow-diverter stenting with considerations for adjunctive coiling: A single-centre experience and literature review.

Authors:  Cunli Yang; Agnes Vadasz; István Szikora
Journal:  Interv Neuroradiol       Date:  2017-07-31       Impact factor: 1.610

5.  Endovascular exclusion of the anterior communicating artery with flow-diverter stents as an emergency treatment for blister-like intracranial aneurysms. A case report.

Authors:  Aymeric Rouchaud; Suzana Saleme; Benjamin Gory; David Ayoub; Charbel Mounayer
Journal:  Interv Neuroradiol       Date:  2013-12-18       Impact factor: 1.610

6.  Flow diverter placement for management of dissecting ruptured aneurysm in a non-fused basilar artery.

Authors:  Guillaume Saliou; Sarah Power; Timo Krings
Journal:  Interv Neuroradiol       Date:  2015-11-30       Impact factor: 1.610

7.  Blister-like aneurysms of middle cerebral artery: a multicenter retrospective review of diagnosis and treatment in three patients.

Authors:  Simone Peschillo; P Missori; M Piano; D Cannizzaro; G Guidetti; A Santoro; M Cenzato
Journal:  Neurosurg Rev       Date:  2014-10-18       Impact factor: 3.042

8.  Endovascular treatment of ruptured blister-like aneurysms with special reference to the flow-diverting strategy.

Authors:  Celal Çinar; İsmail Oran; Halil Bozkaya; Erkin Ozgiray
Journal:  Neuroradiology       Date:  2013-01-16       Impact factor: 2.804

9.  Woven Endobridge (WEB) Device for endovascular treatment of ruptured intracranial wide-neck aneurysms: a single-center experience.

Authors:  Jildaz Caroff; Cristian Mihalea; Francesco Dargento; Hiroaki Neki; Léon Ikka; Nidhal Benachour; Jacques Moret; Laurent Spelle
Journal:  Neuroradiology       Date:  2014-06-15       Impact factor: 2.804

10.  Pipeline embolization device in aneurysmal subarachnoid hemorrhage.

Authors:  J P Cruz; C O'Kelly; M Kelly; J H Wong; W Alshaya; A Martin; J Spears; T R Marotta
Journal:  AJNR Am J Neuroradiol       Date:  2012-10-11       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.