Literature DB >> 21986986

Semi-automated stereoradiographic upper limb 3D reconstructions using a combined parametric and statistical model: a preliminary study.

F Lebailly1, L V P C Lima, A Clairemidi, B Aubert, S Guerard, Y Chaibi, J de Guise, C Fontaine, W Skalli.   

Abstract

PURPOSE: Quantitative assessment of 3D clinical indices may be crucial for elbow surgery planning. 3D parametric modeling from bi-planar radiographs was successfully proposed for spine and lower limb clinical investigation as an alternative for CT-scan. The aim of this study was to adapt this method to the upper limb with a preliminary validation.
METHODS: CT-scan 3D models of humerus, radius and ulna were obtained from 20 cadaveric upper limbs and yielded parametric models made of geometric primitives. Primitives were defined by descriptor parameters (diameters, angles...) and correlations between these descriptors were found. Using these correlations, a semi-automated reconstruction method of humerus using bi-planar radiographs was achieved: a 3D personalized parametric model was built, from which clinical parameters were computed [orientation and projections on bone surface of trochlea sulcus to capitulum (CTS) axis, trochlea sulcus anterior offset and width of distal humeral epiphysis]. This method was evaluated by accuracy compared to CT-scan and reproducibility.
RESULTS: Points-to-surface mean distance was 0.9 mm (2 RMS = 2.5 mm). For clinical parameters, mean differences were 0.4-1.9 mm and from 1.7° to 2.3°. All parameters except from angle formed by CTS axis and bi-epicondylar axis in transverse plane were reproducible. Reconstruction time was about 5 min.
CONCLUSIONS: The presented method provides access to morphological upper limb parameters with very low level of radiation. Preliminary in vitro validation for humerus showed that it is fast and accurate enough to be used in clinical daily practice as an alternative to CT-scan for total elbow arthroplasty pre operative evaluation.

Entities:  

Mesh:

Year:  2011        PMID: 21986986     DOI: 10.1007/s00276-011-0884-9

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  18 in total

1.  Fast accurate stereoradiographic 3D-reconstruction of the spine using a combined geometric and statistic model.

Authors:  Vincent Pomero; David Mitton; Sébastien Laporte; Jacques A de Guise; Wafa Skalli
Journal:  Clin Biomech (Bristol, Avon)       Date:  2004-03       Impact factor: 2.063

2.  3D reconstruction of the pelvis from bi-planar radiography.

Authors:  D Mitton; S Deschênes; S Laporte; B Godbout; S Bertrand; J A de Guise; W Skalli
Journal:  Comput Methods Biomech Biomed Engin       Date:  2006-02       Impact factor: 1.763

3.  Surgeon accuracy in the selection of the flexion-extension axis of the elbow: an in vitro study.

Authors:  James R Brownhill; Keizo Furukawa; Kenneth J Faber; James A Johnson; Graham J W King
Journal:  J Shoulder Elbow Surg       Date:  2006 Jul-Aug       Impact factor: 3.019

4.  Morphologic analysis of the distal humerus with special interest in elbow implant sizing and alignment.

Authors:  James R Brownhill; Graham J W King; James A Johnson
Journal:  J Shoulder Elbow Surg       Date:  2007-04-06       Impact factor: 3.019

5.  3D reconstruction of the spine from biplanar X-rays using parametric models based on transversal and longitudinal inferences.

Authors:  L Humbert; J A De Guise; B Aubert; B Godbout; W Skalli
Journal:  Med Eng Phys       Date:  2009-02-20       Impact factor: 2.242

6.  Surface reconstruction from planar x-ray images using moving least squares.

Authors:  T Cresson; B Godbout; D Branchaud; R Chav; P Gravel; J A De Guise
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

7.  Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays.

Authors:  Y Chaibi; T Cresson; B Aubert; J Hausselle; P Neyret; O Hauger; J A de Guise; W Skalli
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-05-24       Impact factor: 1.763

8.  Loose-hinge total elbow arthroplasty. An experimental study of the effects of implant alignment on three-dimensional elbow kinematics.

Authors:  F Schuind; S O'Driscoll; S Korinek; K N An; B F Morrey
Journal:  J Arthroplasty       Date:  1995-10       Impact factor: 4.757

9.  Kinematics of the elbow.

Authors:  J T London
Journal:  J Bone Joint Surg Am       Date:  1981-04       Impact factor: 5.284

10.  Diagnostic imaging of spinal deformities: reducing patients radiation dose with a new slot-scanning X-ray imager.

Authors:  Sylvain Deschênes; Guy Charron; Gilles Beaudoin; Hubert Labelle; Josée Dubois; Marie-Claude Miron; Stefan Parent
Journal:  Spine (Phila Pa 1976)       Date:  2010-04-20       Impact factor: 3.468

View more
  1 in total

1.  Accuracy of free-hand humeral head resection planned on 3D-CT models in shoulder arthroplasty: an in vitro analysis.

Authors:  Thomas Suter; Ariane Gerber Popp; Christopher W Kolz; Robert Z Tashjian; Heath B Henninger
Journal:  Arch Orthop Trauma Surg       Date:  2021-05-12       Impact factor: 2.928

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.