Literature DB >> 21984496

High range resolution ultrasonographic vascular imaging using frequency domain interferometry with the Capon method.

Hirofumi Taki1, Kousuke Taki, Takuya Sakamoto, Makoto Yamakawa, Tsuyoshi Shiina, Motoi Kudo, Toru Sato.   

Abstract

For high range resolution ultrasonographic vascular imaging, we apply frequency domain interferometry with the Capon method to a single frame of in-phase and quadrature (IQ) data acquired using a commercial ultrasonographic device with a 7.5 MHz linear array probe. In order to tailor the adaptive beam forming algorithm for ultrasonography we employ four techniques: frequency averaging, whitening, radio-frequency data oversampling, and the moving average. The proposed method had a range resolution of 0.05 mm in an ideal condition, and experimentally detected the boundary couple 0.17 mm apart, where the boundary couple was indistinguishable from a single boundary utilizing a B-mode image. Further, this algorithm could depict a swine femoral artery with a range beam width of 0.054 mm and an estimation error for the vessel wall thickness of 0.009 mm, whereas using a conventional method the range beam width and estimation error were 0.182 and 0.021 mm, respectively. The proposed method requires 7.7 s on a mobile PC with a single CPU for a 1×3 cm region of interest. These findings indicate the potential of the proposed method for the improvement of range resolution in ultrasonography without deterioration in temporal resolution, resulting in enhanced detection of vessel stenosis.

Entities:  

Mesh:

Year:  2011        PMID: 21984496     DOI: 10.1109/TMI.2011.2170847

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  Accurate ultrasound imaging based on range point migration method for the depiction of fetal surface.

Authors:  Hirofumi Taki; Shinya Tanimura; Takuya Sakamoto; Tsuyoshi Shiina; Toru Sato
Journal:  J Med Ultrason (2001)       Date:  2014-09-13       Impact factor: 1.314

2.  Amplitude and phase estimator combined with the Wiener postfilter for medical ultrasound imaging.

Authors:  Ali Mohades Deylami; Babak Mohammadzadeh Asl
Journal:  J Med Ultrason (2001)       Date:  2015-10-05       Impact factor: 1.314

3.  Enhancing effect of phase coherence factor for improvement of spatial resolution in ultrasonic imaging.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2015-10-07       Impact factor: 1.314

4.  Twofold minimum variance beamforming for enhanced ultrasound imaging.

Authors:  Sayed Mahmoud Sakhaei; Seyede Elham Shamsian
Journal:  J Med Ultrason (2001)       Date:  2017-04-21       Impact factor: 1.314

5.  Quantitative Frequency-Domain Passive Cavitation Imaging.

Authors:  Kevin J Haworth; Kenneth B Bader; Kyle T Rich; Christy K Holland; T Douglas Mast
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-10-25       Impact factor: 2.725

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.