Literature DB >> 21962448

Three-dimensional echocardiography in paravalvular aortic regurgitation assessment after transcatheter aortic valve implantation.

Alexandra Gonçalves1, Carlos Almeria, Pedro Marcos-Alberca, Gisela Feltes, Rosana Hernández-Antolín, Enrique Rodríguez, José C Silva Cardoso, Carlos Macaya, José Luis Zamorano.   

Abstract

BACKGROUND: Paravalvular aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) is common, but the evaluation of its severity by two-dimensional (2D) transthoracic echocardiography (TTE) presents several constrains. The aim of this study was to assess the usefulness of a new methodology, using three-dimensional (3D) TTE, for better assessment of paravalvular AR after TAVI.
METHODS: Two-dimensional and 3D TTE was performed in 72 patients, 5 months after TAVI, using the X5-1 PureWave microbeamforming xMATRIX probe. The position and severity of the paravalvular AR jets were described using 2D and 3D TTE, and a model was designed for paravalvular AR systematic location description. Vena contracta width was measured using 2D transthoracic echocardiographic views, and the planimetry of the vena contracta was assessed after the perfect alignment plane was obtained using the multiplanar 3D transthoracic echocardiographic reconstruction tool. AR volume was calculated as the difference between 3D TTE-derived total left ventricular stroke volume and right ventricular stroke volume estimated using 2D TTE. Diagnostic efficiency for moderate AR was assessed using receiver operating characteristic curve analysis.
RESULTS: Forty-three patients (57.4%) presented with AR; 10 (13.3%) had central AR, and 33 (44.0%) had paravalvular AR jets. Vena contracta widths were similar between patients with moderate and mild AR (2.1 ± 0.53 vs 1.9 ± 0.16 mm, P = .16), but vena contracta planimetry was larger in patients with moderate AR than in those with mild AR (0.30 ± 0.12 vs 0.09 ± 0.07 cm(2), P = .001). Vena contracta planimetry on 3D TTE was better correlated with AR volume than vena contracta width on 2D TTE (Kendall's τ = 0.82 [P < .001] vs 0.66 [P < .001]). The areas under the receiver operating characteristic curves were 0.96 for vena contracta planimetry and 0.35 for vena contracta width.
CONCLUSIONS: This study proposes an alternative methodology for paravalvular AR assessment after TAVI. Using vena contracta planimetry on 3D TTE, an accurate methodology for paravalvular AR jet evaluation and moderate AR classification is described.
Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21962448     DOI: 10.1016/j.echo.2011.08.019

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  15 in total

Review 1.  Guidance of treatment of perivalvular prosthetic leaks.

Authors:  Daniel Rodríguez Muñoz; Carla Lázaro Rivera; José Luis Zamorano Gómez
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

Review 2.  Guidance of transcatheter aortic valve replacement by echocardiography.

Authors:  Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

Review 3.  Imaging to select and guide transcatheter aortic valve implantation.

Authors:  José Luis Zamorano; Alexandra Gonçalves; Roberto Lang
Journal:  Eur Heart J       Date:  2014-01-23       Impact factor: 29.983

Review 4.  Echocardiographic evaluation of prosthetic heart valves.

Authors:  Haïfa Mahjoub; Philippe Pibarot; Jean-Gaston Dumesnil
Journal:  Curr Cardiol Rep       Date:  2015-06       Impact factor: 2.931

Review 5.  Paravalvular regurgitation following transcutaneous aortic valve replacement: predictors and clinical significance.

Authors:  Rebecca T Hahn; Susheel Kodali; Philippe Généreux; Martin Leon
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

Review 6.  Aortic regurgitation after transcatheter aortic valve implantation: mechanisms and implications.

Authors:  Barbara E Stähli; Willibald Maier; Roberto Corti; Thomas F Lüscher; Rolf Jenni; Felix C Tanner
Journal:  Cardiovasc Diagn Ther       Date:  2013-03

Review 7.  The most important publications of the past year in echocardiography.

Authors:  A Farkhooy; F A Flachskampf
Journal:  Herz       Date:  2013-02       Impact factor: 1.443

Review 8.  [Echocardiography during transcatheter interventions. New developments].

Authors:  J Balzer
Journal:  Herz       Date:  2013-02       Impact factor: 1.443

9.  Practical update on imaging and transcatheter aortic valve implantation.

Authors:  Gisela Feltes; Iván J Núñez-Gil
Journal:  World J Cardiol       Date:  2015-04-26

10.  3D printing based on cardiac CT assists anatomic visualization prior to transcatheter aortic valve replacement.

Authors:  Beth Ripley; Tatiana Kelil; Michael K Cheezum; Alexandra Goncalves; Marcelo F Di Carli; Frank J Rybicki; Mike Steigner; Dimitrios Mitsouras; Ron Blankstein
Journal:  J Cardiovasc Comput Tomogr       Date:  2015-12-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.