Literature DB >> 21960657

Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure.

Guanqun Zhang1, Mingwu Gao, Da Xu, N Bari Olivier, Ramakrishna Mukkamala.   

Abstract

Pulse transit time (PTT) is a proven, simple to measure, marker of blood pressure (BP) that could potentially permit continuous, noninvasive, and cuff-less BP monitoring (after an initial calibration). However, pulse arrival time (PAT), which is equal to the sum of PTT and the pre-ejection period, is gaining popularity for BP tracking, because it is even simpler to measure. The aim of this study was to evaluate the hypothesis that PAT is an adequate surrogate for PTT as a marker of BP. PAT and PTT were estimated through the aorta using high-fidelity invasive arterial waveforms obtained from six dogs during wide BP changes induced by multiple interventions. These time delays and their reciprocals were evaluated in terms of their ability to predict diastolic, mean, and systolic BP (DBP, MBP, and SBP) per animal. The root mean squared error (RMSE) between the BP parameter predicted via the time delay and the measured BP parameter was specifically used as the evaluation metric. Taking the reciprocals of the time delays tended to reduce the RMSE values. The DBP, MBP, and SBP RMSE values for 1/PAT were 9.8 ± 5.2, 10.4 ± 5.6, and 11.9 ± 6.1 mmHg, whereas the corresponding values for 1/PTT were 5.3 ± 1.2, 4.8 ± 1.0, and 7.5 ± 2.2 mmHg (P < 0.05). Thus tracking BP via PAT was not only markedly worse than via PTT but also unable to meet the FDA BP error limits. In contrast to previous studies, our results quantitatively indicate that PAT is not an adequate surrogate for PTT in terms of detecting challenging BP changes.

Entities:  

Mesh:

Year:  2011        PMID: 21960657     DOI: 10.1152/japplphysiol.00980.2011

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  21 in total

1.  Continuous monitoring of cerebrovascular reactivity through pulse transit time and intracranial pressure.

Authors:  Xiuyun Liu; Kais Gadhoumi; Ran Xiao; Nate Tran; Peter Smielewski; Marek Czosnyka; Steven W Hetts; Nerissa Ko; Xiao Hu
Journal:  Physiol Meas       Date:  2019-01-23       Impact factor: 2.833

Review 2.  Learning and non-learning algorithms for cuffless blood pressure measurement: a review.

Authors:  Nishigandha Dnyaneshwar Agham; Uttam M Chaskar
Journal:  Med Biol Eng Comput       Date:  2021-06-03       Impact factor: 2.602

3.  Towards Continuous and Ambulatory Blood Pressure Monitoring: Methods for Efficient Data Acquisition for Pulse Transit Time Estimation.

Authors:  Oludotun Ode; Lara Orlandic; Omer T Inan
Journal:  Sensors (Basel)       Date:  2020-12-11       Impact factor: 3.576

4.  Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring.

Authors:  Chang-Sei Kim; Andrew M Carek; Ramakrishna Mukkamala; Omer T Inan; Jin-Oh Hahn
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-02       Impact factor: 4.538

5.  Robust Sensing of Distal Pulse Waveforms on a Modified Weighing Scale for Ubiquitous Pulse Transit Time Measurement.

Authors:  Andrew M Carek; Omer T Inan
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2017-05-23       Impact factor: 3.833

Review 6.  Wearable ballistocardiogram and seismocardiogram systems for health and performance.

Authors:  Mozziyar Etemadi; Omer T Inan
Journal:  J Appl Physiol (1985)       Date:  2017-08-10

7.  Pulse Arrival Time Based Cuff-Less and 24-H Wearable Blood Pressure Monitoring and its Diagnostic Value in Hypertension.

Authors:  Yali Zheng; Carmen C Y Poon; Bryan P Yan; James Y W Lau
Journal:  J Med Syst       Date:  2016-07-22       Impact factor: 4.460

8.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

9.  Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera.

Authors:  In Cheol Jeong; Joseph Finkelstein
Journal:  J Med Syst       Date:  2016-01-20       Impact factor: 4.460

10.  "Sleep disordered breathing and ECG R-wave to radial artery pulse delay, The Multi-Ethnic Study of Atherosclerosis".

Authors:  Younghoon Kwon; David R Jacobs; Pamela L Lutsey; Lyndia Brumback; Julio A Chirinos; Sara Mariani; Susan Redline; Daniel A Duprez
Journal:  Sleep Med       Date:  2018-05-21       Impact factor: 3.492

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.