Pulse Arrival Time Based Cuff-Less and 24-H Wearable Blood Pressure Monitoring and its Diagnostic Value in Hypertension.

Yali Zheng1, Carmen C Y Poon2, Bryan P Yan3, James Y W Lau1.   

Abstract

Ambulatory blood pressure monitoring (ABPM) has become an essential tool in the diagnosis and management of hypertension. Current standard ABPM devices use an oscillometric cuff-based method which can cause physical discomfort to the patients with repeated inflations and deflations, especially during nighttime leading to sleep disturbance. The ability to measure ambulatory BP accurately and comfortably without a cuff would be attractive. This study validated the accuracy of a cuff-less approach for ABPM using pulse arrival time (PAT) measurements on both healthy and hypertensive subjects for potential use in hypertensive management, which is the first of its kind. The wearable cuff-less device was evaluated against a standard cuff-based device on 24 subjects of which 15 have known hypertension. BP measurements were taken from each subject over a 24-h period by the cuff-less and cuff-based devices every 15 to 30 minutes during daily activities. Mean BP of each subject during daytime, nighttime and over 24-h were calculated. Agreement between mean nighttime systolic BP (SBP) and diastolic (DBP) measured by the two devices evaluated using Bland-Altman plot were -1.4 ± 6.6 and 0.4 ± 6.7 mmHg, respectively. Receiver operator characteristics (ROC) statistics was used to assess the diagnostic accuracy of the cuff-less approach in the detection of BP above the hypertension threshold during nighttime (>120/70 mmHg). The area under ROC curves were 0.975/0.79 for nighttime. The results suggest that PAT-based approach is accurate and promising for ABPM without the issue of sleep disturbances associated with cuff-based devices.

Entities:  

Keywords:  Body sensor network; Cuff-less blood pressure; Mobile health; Pulse arrival time; Wearable

Mesh:

Year:  2016        PMID: 27447469     DOI: 10.1007/s10916-016-0558-6

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  36 in total

1.  The effects of pre-ejection period on post-exercise systolic blood pressure estimation using the pulse arrival time technique.

Authors:  Mico Yee Man Wong; Emma Pickwell-MacPherson; Yuan Ting Zhang; Jack C Y Cheng
Journal:  Eur J Appl Physiol       Date:  2010-09-08       Impact factor: 3.078

2.  Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research.

Authors:  Thomas G Pickering; John E Hall; Lawrence J Appel; Bonita E Falkner; John Graves; Martha N Hill; Daniel W Jones; Theodore Kurtz; Sheldon G Sheps; Edward J Roccella
Journal:  Hypertension       Date:  2004-12-20       Impact factor: 10.190

3.  Innovative continuous non-invasive cuffless blood pressure monitoring based on photoplethysmography technology.

Authors:  Juan C Ruiz-Rodríguez; Adolf Ruiz-Sanmartín; Vicent Ribas; Jesús Caballero; Alejandra García-Roche; Jordi Riera; Xavier Nuvials; Miriam de Nadal; Oriol de Sola-Morales; Joaquim Serra; Jordi Rello
Journal:  Intensive Care Med       Date:  2013-06-06       Impact factor: 17.440

4.  An examination of calibration intervals required for accurately tracking blood pressure using pulse transit time algorithms.

Authors:  B M McCarthy; C J Vaughan; B O'Flynn; A Mathewson; C Ó Mathúna
Journal:  J Hum Hypertens       Date:  2013-05-23       Impact factor: 3.012

Review 5.  A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time.

Authors:  Dilpreet Buxi; Jean-Michel Redouté; Mehmet Rasit Yuce
Journal:  Physiol Meas       Date:  2015-02-19       Impact factor: 2.833

6.  An armband wearable device for overnight and cuff-less blood pressure measurement.

Authors:  Ya-Li Zheng; Bryan P Yan; Yuan-Ting Zhang; Carmen C Y Poon
Journal:  IEEE Trans Biomed Eng       Date:  2014-04-18       Impact factor: 4.538

7.  Ambulatory blood pressure is superior to clinic blood pressure in predicting treatment-induced regression of left ventricular hypertrophy. SAMPLE Study Group. Study on Ambulatory Monitoring of Blood Pressure and Lisinopril Evaluation.

Authors:  G Mancia; A Zanchetti; E Agabiti-Rosei; G Benemio; R De Cesaris; R Fogari; A Pessina; C Porcellati; A Rappelli; A Salvetti; B Trimarco; E Agebiti-Rosei; A Pessino
Journal:  Circulation       Date:  1997-03-18       Impact factor: 29.690

8.  The influence of aging on the human sympathetic nervous system and brain norepinephrine turnover.

Authors:  Murray Esler; Jacqueline Hastings; Gavin Lambert; David Kaye; Garry Jennings; Douglas R Seals
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2002-03       Impact factor: 3.619

9.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

10.  2013 ESH/ESC guidelines for the management of arterial hypertension: the Task Force for the Management of Arterial Hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC).

Authors:  Giuseppe Mancia; Robert Fagard; Krzysztof Narkiewicz; Josep Redon; Alberto Zanchetti; Michael Böhm; Thierry Christiaens; Renata Cifkova; Guy De Backer; Anna Dominiczak; Maurizio Galderisi; Diederick E Grobbee; Tiny Jaarsma; Paulus Kirchhof; Sverre E Kjeldsen; Stéphane Laurent; Athanasios J Manolis; Peter M Nilsson; Luis Miguel Ruilope; Roland E Schmieder; Per Anton Sirnes; Peter Sleight; Margus Viigimaa; Bernard Waeber; Faiez Zannad; Josep Redon; Anna Dominiczak; Krzysztof Narkiewicz; Peter M Nilsson; Michel Burnier; Margus Viigimaa; Ettore Ambrosioni; Mark Caufield; Antonio Coca; Michael Hecht Olsen; Roland E Schmieder; Costas Tsioufis; Philippe van de Borne; Jose Luis Zamorano; Stephan Achenbach; Helmut Baumgartner; Jeroen J Bax; Héctor Bueno; Veronica Dean; Christi Deaton; Cetin Erol; Robert Fagard; Roberto Ferrari; David Hasdai; Arno W Hoes; Paulus Kirchhof; Juhani Knuuti; Philippe Kolh; Patrizio Lancellotti; Ales Linhart; Petros Nihoyannopoulos; Massimo F Piepoli; Piotr Ponikowski; Per Anton Sirnes; Juan Luis Tamargo; Michal Tendera; Adam Torbicki; William Wijns; Stephan Windecker; Denis L Clement; Antonio Coca; Thierry C Gillebert; Michal Tendera; Enrico Agabiti Rosei; Ettore Ambrosioni; Stefan D Anker; Johann Bauersachs; Jana Brguljan Hitij; Mark Caulfield; Marc De Buyzere; Sabina De Geest; Geneviève Anne Derumeaux; Serap Erdine; Csaba Farsang; Christian Funck-Brentano; Vjekoslav Gerc; Giuseppe Germano; Stephan Gielen; Herman Haller; Arno W Hoes; Jens Jordan; Thomas Kahan; Michel Komajda; Dragan Lovic; Heiko Mahrholdt; Michael Hecht Olsen; Jan Ostergren; Gianfranco Parati; Joep Perk; Jorge Polonia; Bogdan A Popescu; Zeljko Reiner; Lars Rydén; Yuriy Sirenko; Alice Stanton; Harry Struijker-Boudier; Costas Tsioufis; Philippe van de Borne; Charalambos Vlachopoulos; Massimo Volpe; David A Wood
Journal:  Eur Heart J       Date:  2013-06-14       Impact factor: 29.983

View more
  16 in total

1.  Assessing pulse transit time to the skeletal muscle microcirculation using near-infrared spectroscopy.

Authors:  Cody P Anderson; Song-Young Park
Journal:  J Appl Physiol (1985)       Date:  2022-07-14

2.  Estimating Blood Pressure from the Photoplethysmogram Signal and Demographic Features Using Machine Learning Techniques.

Authors:  Moajjem Hossain Chowdhury; Md Nazmul Islam Shuzan; Muhammad E H Chowdhury; Zaid B Mahbub; M Monir Uddin; Amith Khandakar; Mamun Bin Ibne Reaz
Journal:  Sensors (Basel)       Date:  2020-06-01       Impact factor: 3.576

3.  Blood Pressure Estimation Using On-body Continuous Wave Radar and Photoplethysmogram in Various Posture and Exercise Conditions.

Authors:  Malikeh Pour Ebrahim; Fatemeh Heydari; Taiyang Wu; Katherine Walker; Keith Joe; Jean-Michel Redoute; Mehmet Rasit Yuce
Journal:  Sci Rep       Date:  2019-11-08       Impact factor: 4.379

4.  An Optimization Study of Estimating Blood Pressure Models Based on Pulse Arrival Time for Continuous Monitoring.

Authors:  Jiang Shao; Ping Shi; Sijung Hu; Yang Liu; Hongliu Yu
Journal:  J Healthc Eng       Date:  2020-02-10       Impact factor: 2.682

5.  Overexpression of microRNA-506-3p aggravates the injury of vascular endothelial cells in patients with hypertension by downregulating Beclin1 expression.

Authors:  Fanfan Yi; Yugui Hao; Xiaoyi Chong; Wei Zhong
Journal:  Exp Ther Med       Date:  2018-01-10       Impact factor: 2.447

6.  Management of Hypertension in the Digital Era: Small Wearable Monitoring Devices for Remote Blood Pressure Monitoring.

Authors:  Kazuomi Kario
Journal:  Hypertension       Date:  2020-08-03       Impact factor: 10.190

7.  Alterations of blood pulsations parameters in carotid basin due to body position change.

Authors:  Alexei A Kamshilin; Tatiana V Krasnikova; Maxim A Volynsky; Serguei V Miridonov; Oleg V Mamontov
Journal:  Sci Rep       Date:  2018-09-12       Impact factor: 4.379

Review 8.  The use of photoplethysmography for assessing hypertension.

Authors:  Mohamed Elgendi; Richard Fletcher; Yongbo Liang; Newton Howard; Nigel H Lovell; Derek Abbott; Kenneth Lim; Rabab Ward
Journal:  NPJ Digit Med       Date:  2019-06-26

9.  Validation and Acceptability of a Cuffless Wrist-Worn Wearable Blood Pressure Monitoring Device Among Users and Health Care Professionals: Mixed Methods Study.

Authors:  Sheikh Mohammed Shariful Islam; Clara Chow; Ralph Maddison; Susie Cartledge; Chandan Karmakar; Jonathan Charles Rawstorn; Steve F Fraser
Journal:  JMIR Mhealth Uhealth       Date:  2019-09-14       Impact factor: 4.773

10.  A Revised Point-to-Point Calibration Approach with Adaptive Errors Correction to Weaken Initial Sensitivity of Cuff-Less Blood Pressure Estimation.

Authors:  Jiang Shao; Ping Shi; Sijung Hu; Hongliu Yu
Journal:  Sensors (Basel)       Date:  2020-04-13       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.