Literature DB >> 21959750

Transfemoral implantation of an Edwards SAPIEN valve in a tricuspid bioprosthesis without fluoroscopic landmarks.

Patrick A Calvert1, Dominique Himbert, Eric Brochet, Costin Radu, Bernard Iung, Ulrik Hvass, Jean-Marc Darondel, Jean-Pol Depoix, Patrick Nataf, Alec Vahanian.   

Abstract

AIMS: We describe the first report of an Edwards SAPIEN valve implanted in a tricuspid bioprosthesis from the femoral vein. We highlight the feasibility of this previously avoided approach and the techniques involved. METHODS AND
RESULTS: A 61-year-old woman with multiple valve replacements for rheumatic heart disease presented with NHYA IV dyspnoea secondary to a severely stenosed tricuspid bioprosthesis. After failed aggressive medical therapy and surgical turn down, an Edwards SAPIEN XT valve was deployed in the tricuspid bioprosthesis via the right femoral vein. Adaptations to the standard transfemoral transcatheter aortic valve implantation (TAVI) technique included: (1) crossing the tricuspid bioprosthesis with a balloon floatation catheter; (2) temporary pacing wire in the coronary sinus rather than the right ventricle; (3) mounting of the SAPIEN XT valve in the reverse orientation to transfemoral TAVI; and (4) fine positioning of the final valve position pre-deployment by 3D transoesophageal echocardiography (3D TOE) alone due to complete radiolucency of the tricuspid bioprosthesis. The procedure was completed without complication and resulted in significant symptomatic improvement.
CONCLUSIONS: Deployment of an Edwards SAPIEN valve in a tricuspid bioprosthesis via the femoral vein is feasible and, with careful adaptations to established TAVI techniques, can be performed without complications and with good clinical response.

Entities:  

Mesh:

Year:  2012        PMID: 21959750     DOI: 10.4244/EIJV7I11A209

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  6 in total

1.  Transcatheter Advances in the Treatment of Adult and Congenital Valvular Heart Disease.

Authors:  Jayendrakumar S Patel; Samir R Kapadia; Lourdes Prieto; E Murat Tuzcu; Amar Krishnaswamy
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-11

Review 2.  Valve-in-valve implantations: is this the new standard for degenerated bioprostheses? Review of the literature.

Authors:  Krys Milburn; Vinayak Bapat; Martyn Thomas
Journal:  Clin Res Cardiol       Date:  2014-01-21       Impact factor: 5.460

Review 3.  [Interventions at the tricuspid valve: What is possible?].

Authors:  Alexander Lauten; H-R Figulla
Journal:  Herz       Date:  2015-08       Impact factor: 1.443

4.  Computer Vision Techniques for Transcatheter Intervention.

Authors:  Feng Zhao; Xianghua Xie; Matthew Roach
Journal:  IEEE J Transl Eng Health Med       Date:  2015-06-18       Impact factor: 3.316

Review 5.  Impact of Right-Sided-Catheter-Based Valve Implantation on Decision-Making in Congenital Heart Disease.

Authors:  Joanna Ghobrial; Jamil Aboulhosn
Journal:  Curr Cardiol Rep       Date:  2016-04       Impact factor: 2.931

6.  Noninvasive pacing during transfemoral implantation of the Edwards SAPIEN valve for tricuspid valve bioprosthesis stenosis.

Authors:  Marcin Demkow; Witold Rużyłło; Sebastian Bujak; Marek Konka; Piotr Szatkowski; Barbara Lubiszewska
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-02-11       Impact factor: 1.426

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.