Literature DB >> 21959426

Correlation between bone density and angular deviation of implants placed using CT-generated surgical guides.

Oguz Ozan1, Kaan Orhan, Ilser Turkyilmaz.   

Abstract

BACKGROUND: The aim of this study was to evaluate the correlation between the density of bone where implants were placed and the angular deviations that occurred between the virtually planned and actually placed implants using 2 different stereolithographic surgical guides.
METHODS: The study population consisted of 54 patients who received 216 implants. Computed tomography machine was used for preoperative evaluation of the jawbone for implant therapy as well as determination of the bone density values (Hounsfield units [HU]) of the implantation site. All implant sockets were prepared using 2 different types of stereolithographic surgical guide. Ninety-four implants were installed using the surgical guides (Stentcad Beyond, Ay-Design; Kos-gep, ODTU, Ankara, Turkey) in the mouth, whereas 122 implants were placed after the surgical guides (Stentcad Classic; Kos-gep, ODTU) were removed.
RESULTS: The mean bone densities of maxilla and mandible were 561.36 (SD, 229.46) HU and 890.63 (SD, 361.85) HU, respectively. The mean angular deviations between planned and placed implants using Stentcad Classic and Stentcad Beyond surgical guides were 5.32 (SD, 1.96) degrees and 3.73 (SD, 1.14) degrees, respectively. Highly negative correlation was found between the bone density of the placed implant sites and angular deviations in the group in whom implants were installed with freehand.
CONCLUSIONS: The lower bone density values have resulted in the greater angular deviations in the group, in whom the implants were placed after the surgical guides were removed. This deviation might have been derived from the freehand placement of the implants and the poor quality of the bone.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21959426     DOI: 10.1097/SCS.0b013e31822e6305

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  9 in total

1.  [Research advances in the use of digital surgical guides in implantology].

Authors:  Xiao-Hua Wang; Ai-Peng Liu; Wen-Zheng Deng
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-02-01

2.  Accuracy of half-guided implant placement with machine-driven or manual insertion: a prospective, randomized clinical study.

Authors:  Kristof Orban; Endre Varga; Peter Windisch; Gabor Braunitzer; Balint Molnar
Journal:  Clin Oral Investig       Date:  2021-08-16       Impact factor: 3.606

3.  Comparison of Different Types of Static Computer-Guided Implant Surgery in Varying Bone Inclinations.

Authors:  Pisut Thangwarawut; Pokpong Amornvit; Dinesh Rokaya; Sirichai Kiattavorncharoen
Journal:  Materials (Basel)       Date:  2022-04-20       Impact factor: 3.748

Review 4.  Advantages and limitations of implant surgery with CAD/CAM surgical guides: A literature review.

Authors:  Gokce-Soganci Unsal; Ilser Turkyilmaz; Samantha Lakhia
Journal:  J Clin Exp Dent       Date:  2020-04-01

5.  Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol.

Authors:  Corina Marilena Cristache; Silviu Gurbanescu
Journal:  Int J Dent       Date:  2017-05-07

Review 6.  Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: a Systematic Review.

Authors:  Cheongbeom Seo; Gintaras Juodzbalys
Journal:  J Oral Maxillofac Res       Date:  2018-03-31

7.  Utilising the nasal aperture for template stabilisation for guided surgery in the atrophic maxilla.

Authors:  Pieter Onclin; Joep Kraeima; Bram B J Merema; Henny J A Meijer; Arjan Vissink; Gerry M Raghoebar
Journal:  Int J Implant Dent       Date:  2020-06-26

8.  Accuracy of computer-guided implantation in the placement of one-piece ceramic dental implants in the anterior region: A prospective clinical study.

Authors:  Nopparat Suksod; Chatchai Kunavisarut; Jira Kitisubkanchana
Journal:  PLoS One       Date:  2020-09-14       Impact factor: 3.240

9.  Influence of bone condition on implant placement accuracy with computer-guided surgery.

Authors:  Ramadhan Hardani Putra; Nobuhiro Yoda; Masahiro Iikubo; Yoshihiro Kataoka; Kensuke Yamauchi; Shigeto Koyama; Upul Cooray; Eha Renwi Astuti; Tetsu Takahashi; Keiichi Sasaki
Journal:  Int J Implant Dent       Date:  2020-09-20
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.