Reliability of near infrared spectroscopy (NIRS) for measuring forearm oxygenation during incremental handgrip exercise.

Bert Celie1, Jan Boone, Rudy Van Coster, Jan Bourgois.   

Abstract

The purpose of this study was to test the reliability of a new handgrip exercise protocol measuring forearm oxygenation in 20 healthy subjects on two occasions. The retest took place 48 h later and at the same time of the day. The incremental exercise consisted of 2 min steps of cyclic handgrip contraction (1/2 Hz) separated by 1 min of recovery. The exercise started at 20% MVC, was increased with 10% MVC each step and was performed until exhaustion (69.5 and 73% MVC). Near infrared spectroscopy (NIRS) was used to measure deoxygenation (deoxy[Hb + Mb]) and oxygen saturation (SmO(2)) in the forearm muscles. Prior to the exercise protocol an arterial occlusion of the forearm was performed until deoxy(Hb + Mb) did no longer increase. Maximal increase in deoxy[Hb + Mb] during 10 s of each exercise bout was expressed relative to the occlusion amplitude. ICC was used to examine the test-retest reliability. Significant ICC's were reported at 50% (r = 0.466, p = 0.017) and 60% MVC (r = 0.553, p = 0.005). The group mean of the maximum increase in oxygen extraction was 45.6 ± 16.7% and at the retest 44.9 ± 17.0% with an ICC of r = 0.867 (p < 0.001) which could be classified (Landis and Koch 1979) as almost perfect. The absolute SmO(2) values showed reliable ICC's for every submaximal intensity except at 60% MVC. An ICC of r = 0.774 (p < 0.001) was found at maximal intensity. The results of the present study show that deoxy[Hb + Mb] and SmO(2) responses during this protocol are highly reliable and indicate that this protocol could be used to get insight into deoxygenation and oxygen saturation in a population with low exercise tolerance.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21952981     DOI: 10.1007/s00421-011-2183-x

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  12 in total

1.  Simultaneous measurements of cerebral oxygenation changes during brain activation by near-infrared spectroscopy and functional magnetic resonance imaging in healthy young and elderly subjects.

Authors:  D Jannet Mehagnoul-Schipper; Bas F W van der Kallen; Willy N J M Colier; Marco C van der Sluijs; Leon J Th O van Erning; Henk O M Thijssen; Berend Oeseburg; Willibrord H L Hoefnagels; René W M M Jansen
Journal:  Hum Brain Mapp       Date:  2002-05       Impact factor: 5.038

2.  Reliability of erector spinae oxygenation and blood volume responses using near-infrared spectroscopy in healthy males.

Authors:  Robert T Kell; Mamdouh Farag; Yagesh Bhambhani
Journal:  Eur J Appl Physiol       Date:  2004-01-14       Impact factor: 3.078

3.  Skin blood flow differentially affects near-infrared spectroscopy-derived measures of muscle oxygen saturation and blood volume at rest and during dynamic leg exercise.

Authors:  Garry A Tew; Alan D Ruddock; John M Saxton
Journal:  Eur J Appl Physiol       Date:  2010-08-11       Impact factor: 3.078

Review 4.  A brief review of the use of near infrared spectroscopy with particular interest in resistance exercise.

Authors:  Marta I R Pereira; Paulo S C Gomes; Yagesh N Bhambhani
Journal:  Sports Med       Date:  2007       Impact factor: 11.136

5.  A temporal comparison of BOLD, ASL, and NIRS hemodynamic responses to motor stimuli in adult humans.

Authors:  T J Huppert; R D Hoge; S G Diamond; M A Franceschini; D A Boas
Journal:  Neuroimage       Date:  2005-11-21       Impact factor: 6.556

6.  Reliability of near-infrared spectroscopy for measuring biceps brachii oxygenation during sustained and repeated isometric contractions.

Authors:  Makii Muthalib; Guillaume Y Millet; Valentina Quaresima; Kazunori Nosaka
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

7.  Effect of exercise protocol on deoxy[Hb + Mb]: incremental step versus ramp exercise.

Authors:  Jan Boone; Katrien Koppo; Thomas J Barstow; Jacques Bouckaert
Journal:  Med Sci Sports Exerc       Date:  2010-05       Impact factor: 5.411

Review 8.  Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease.

Authors:  R Boushel; H Langberg; J Olesen; J Gonzales-Alonzo; J Bülow; M Kjaer
Journal:  Scand J Med Sci Sports       Date:  2001-08       Impact factor: 4.221

9.  In vivo quantitative near-infrared spectroscopy in skeletal muscle during incremental isometric handgrip exercise.

Authors:  Mireille C P van Beekvelt; Baziel G M van Engelen; Ron A Wevers; Willy N J M Colier
Journal:  Clin Physiol Funct Imaging       Date:  2002-05       Impact factor: 2.273

10.  Impaired oxygen extraction in metabolic myopathies: detection and quantification by near-infrared spectroscopy.

Authors:  Bruno Grassi; Mauro Marzorati; Francesca Lanfranconi; Alessandra Ferri; Miriam Longaretti; Andrea Stucchi; Paola Vago; Claudio Marconi; Lucia Morandi
Journal:  Muscle Nerve       Date:  2007-04       Impact factor: 3.217

View more
  11 in total

1.  Reliability of near-infrared spectroscopy for measuring forearm and shoulder oxygenation in healthy males and females.

Authors:  Albert G Crenshaw; Guilherme H Elcadi; Fredrik Hellstrom; Svend Erik Mathiassen
Journal:  Eur J Appl Physiol       Date:  2011-11-23       Impact factor: 3.078

2.  Influence of heat stress and exercise intensity on vastus lateralis muscle and prefrontal cortex oxygenation.

Authors:  Julien D Périard; Martin W Thompson; Corinne Caillaud; Valentina Quaresima
Journal:  Eur J Appl Physiol       Date:  2012-05-31       Impact factor: 3.078

3.  Limb blood flow and tissue perfusion during exercise with blood flow restriction.

Authors:  Matthew A Kilgas; John McDaniel; Jon Stavres; Brandon S Pollock; Tyler J Singer; Steven J Elmer
Journal:  Eur J Appl Physiol       Date:  2018-11-12       Impact factor: 3.078

4.  Cross-section and feasibility study on the non-invasive evaluation of muscle hemodynamic responses in Duchenne muscular dystrophy by using a near-infrared diffuse optical technique.

Authors:  Wen-Chin Weng; Jung-Chih Chen; Chia-Yen Lee; Chia-Wei Lin; Wang-Tso Lee; Jeng-Yi Shieh; Chia-Chen Wang; Ching-Cheng Chuang
Journal:  Biomed Opt Express       Date:  2018-09-12       Impact factor: 3.732

5.  Impairments in microvascular function and skeletal muscle oxygenation in women with gestational diabetes mellitus: links to cardiovascular disease risk factors.

Authors:  Konstantina Dipla; Areti Triantafyllou; Iris Grigoriadou; Evangelia Kintiraki; Georgios A Triantafyllou; Pavlos Poulios; Ioannis S Vrabas; Andreas Zafeiridis; Stella Douma; Dimitrios G Goulis
Journal:  Diabetologia       Date:  2016-10-08       Impact factor: 10.122

6.  Hemodynamic function during finger force production tasks in healthy adults.

Authors:  Luca Pollonini; Lena Younes; Stacey L Gorniak
Journal:  Muscle Nerve       Date:  2017-03-29       Impact factor: 3.217

7.  Acute Effects of Cocoa Flavanols on Blood Pressure and Peripheral Vascular Reactivity in Type 2 Diabetes Mellitus and Essential Hypertension: A Protocol for an Acute, Randomized, Double-Blinded, Placebo-Controlled Cross-Over Trial.

Authors:  Anouk Tanghe; Bert Celie; Samyah Shadid; Ernst Rietzschel; Jos Op 't Roodt; Koen D Reesink; Elsa Heyman; Patrick Calders
Journal:  Front Cardiovasc Med       Date:  2021-03-15

8.  Oxygenation Threshold Derived from Near-Infrared Spectroscopy: Reliability and Its Relationship with the First Ventilatory Threshold.

Authors:  Stephan van der Zwaard; Richard T Jaspers; Ilse J Blokland; Chantal Achterberg; Jurrian M Visser; Anne R den Uil; Mathijs J Hofmijster; Koen Levels; Dionne A Noordhof; Arnold de Haan; Jos J de Koning; Willem J van der Laarse; Cornelis J de Ruiter
Journal:  PLoS One       Date:  2016-09-15       Impact factor: 3.240

9.  The effects of hypoxia on muscle deoxygenation and recruitment in the flexor digitorum superficialis during submaximal intermittent handgrip exercise.

Authors:  Hayley J Nell; Laura M Castelli; Dino Bertani; Aaron A Jipson; Sean F Meagher; Luana T Melo; Karl Zabjek; W Darlene Reid
Journal:  BMC Sports Sci Med Rehabil       Date:  2020-05-15

10.  Test-retest reliability of functional near infrared spectroscopy in infants.

Authors:  Anna Blasi; Sarah Lloyd-Fox; Mark H Johnson; Clare Elwell
Journal:  Neurophotonics       Date:  2014-09-08       Impact factor: 3.593

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.