Literature DB >> 20210482

Reliability of near-infrared spectroscopy for measuring biceps brachii oxygenation during sustained and repeated isometric contractions.

Makii Muthalib1, Guillaume Y Millet, Valentina Quaresima, Kazunori Nosaka.   

Abstract

We examine the test-retest reliability of biceps brachii tissue oxygenation index (TOI) parameters measured by near-infrared spectroscopy during a 10-s sustained and a 30-repeated (1-s contraction, 1-s relaxation) isometric contraction task at 30% of maximal voluntary contraction (30% MVC) and maximal (100% MVC) intensities. Eight healthy men (23 to 33 yr) were tested on three sessions separated by 3 h and 24 h, and the within-subject reliability of torque and each TOI parameter were determined by Bland-Altman+/-2 SD limits of agreement plots and coefficient of variation (CV). No significant (P>0.05) differences between the three sessions were found for mean values of torque and TOI parameters during the sustained and repeated tasks at both contraction intensities. All TOI parameters were within+/-2 SD limits of agreement. The CVs for torque integral were similar between the sustained and repeated task at both intensities (4 to 7%); however, the CVs for TOI parameters during the sustained and repeated task were lower for 100% MVC (7 to 11%) than for 30% MVC (22 to 36%). It is concluded that the reliability of the biceps brachii NIRS parameters during both sustained and repeated isometric contraction tasks is acceptable.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20210482     DOI: 10.1117/1.3309746

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  21 in total

1.  Reliability of near-infrared spectroscopy for measuring forearm and shoulder oxygenation in healthy males and females.

Authors:  Albert G Crenshaw; Guilherme H Elcadi; Fredrik Hellstrom; Svend Erik Mathiassen
Journal:  Eur J Appl Physiol       Date:  2011-11-23       Impact factor: 3.078

2.  Reliability of near infrared spectroscopy (NIRS) for measuring forearm oxygenation during incremental handgrip exercise.

Authors:  Bert Celie; Jan Boone; Rudy Van Coster; Jan Bourgois
Journal:  Eur J Appl Physiol       Date:  2011-09-28       Impact factor: 3.078

3.  Near infrared spectroscopy-derived interstitial hydrogen ion concentration and tissue oxygen saturation during ambulation.

Authors:  Stuart M C Lee; Mark S F Clarke; Daniel P O'Connor; Leah Stroud; Gwenn E C Ellerby; Babs R Soller
Journal:  Eur J Appl Physiol       Date:  2011-01-07       Impact factor: 3.078

4.  Influence of heat stress and exercise intensity on vastus lateralis muscle and prefrontal cortex oxygenation.

Authors:  Julien D Périard; Martin W Thompson; Corinne Caillaud; Valentina Quaresima
Journal:  Eur J Appl Physiol       Date:  2012-05-31       Impact factor: 3.078

5.  Muscle oxygen extraction and lung function are related to exercise tolerance after allogeneic hematopoietic stem cell transplantation.

Authors:  Tatsushi Wakasugi; Shinichiro Morishita; Katsuji Kaida; Kazuhiro Ikegame; Yuki Uchiyama; Kazuhisa Domen
Journal:  Support Care Cancer       Date:  2021-03-30       Impact factor: 3.603

6.  Impaired skeletal muscle oxygenation following allogeneic hematopoietic stem cell transplantation is associated with exercise capacity.

Authors:  Tatsushi Wakasugi; Shinichiro Morishita; Katsuji Kaida; Yusuke Itani; Norihiko Kodama; Kazuhiro Ikegame; Hiroyasu Ogawa; Kazuhisa Domen
Journal:  Support Care Cancer       Date:  2018-01-25       Impact factor: 3.603

7.  Repeated sprint training under hypoxia improves aerobic performance and repeated sprint ability by enhancing muscle deoxygenation and markers of angiogenesis in rugby sevens.

Authors:  Wadee Pramkratok; Tongthong Songsupap; Tossaporn Yimlamai
Journal:  Eur J Appl Physiol       Date:  2022-01-03       Impact factor: 3.078

8.  Near infrared spectroscopy for measuring changes in bone hemoglobin content after exercise in individuals with spinal cord injury.

Authors:  Adina E Draghici; Diane Potart; Joseph L Hollmann; Vivian Pera; Qianqian Fang; Charles A DiMarzio; J Andrew Taylor; Mark J Niedre; Sandra J Shefelbine
Journal:  J Orthop Res       Date:  2017-06-28       Impact factor: 3.494

Review 9.  A review of non-invasive techniques to detect and predict localised muscle fatigue.

Authors:  Mohamed R Al-Mulla; Francisco Sepulveda; Martin Colley
Journal:  Sensors (Basel)       Date:  2011-03-24       Impact factor: 3.576

10.  Acute microcirculatory effects of medium frequency versus high frequency neuromuscular electrical stimulation in critically ill patients - a pilot study.

Authors:  Epameinondas Angelopoulos; Eleftherios Karatzanos; Stavros Dimopoulos; Georgios Mitsiou; Christos Stefanou; Irini Patsaki; Anastasia Kotanidou; Christina Routsi; George Petrikkos; Serafeim Nanas
Journal:  Ann Intensive Care       Date:  2013-12-19       Impact factor: 6.925

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.