Literature DB >> 21950780

Why use automated office blood pressure measurements in clinical practice?

Emmanuel A Andreadis1, Epameinondas T Angelopoulos, Gerasimos D Agaliotis, Athanasios P Tsakanikas, George P Mousoulis.   

Abstract

Automated office blood pressure (AOBP) measurement with the patient resting alone in a quiet examining room can eliminate the white-coat effect associated with conventional readings taken by manual sphygmomanometer. The key to reducing the white-coat response appears to be multiple blood pressure (BP) readings taken in a non-observer office setting, thus eliminating any interaction that could provoke an office-induced increase in BP. Furthermore, AOBP readings have shown a higher correlation with the mean awake ambulatory BP compared with BP readings recorded in routine clinical practice. Although there is a paucity of studies connecting AOBP with organ damage, AOBP values were recently found to be equally associated with left ventricular mass index as those of ambulatory BP. This concludes that in contrast to routine manual office BP, AOBP readings compare favourably with 24-hour ambulatory BP measurements in the appraisal of cardiac remodelling and, as such, could be complementary to ambulatory readings in a way similar to home BP measurements.

Entities:  

Mesh:

Year:  2011        PMID: 21950780     DOI: 10.2165/11593510-000000000-00000

Source DB:  PubMed          Journal:  High Blood Press Cardiovasc Prev        ISSN: 1120-9879


  19 in total

1.  Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults.

Authors:  W B White; Y A Anwar
Journal:  Blood Press Monit       Date:  2001-04       Impact factor: 1.444

2.  Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor.

Authors:  J M Wright; G S Mattu; T L Perry; M E Gelferc; K D Strange; A Zorn; Y Chen
Journal:  Blood Press Monit       Date:  2001-06       Impact factor: 1.444

3.  Consistent relationship between automated office blood pressure recorded in different settings.

Authors:  Martin G Myers; Miguel Valdivieso; Alexander Kiss
Journal:  Blood Press Monit       Date:  2009-06       Impact factor: 1.444

Review 4.  Measurement of blood pressure in the office: recognizing the problem and proposing the solution.

Authors:  Martin G Myers; Marshall Godwin; Martin Dawes; Alexander Kiss; Sheldon W Tobe; Janusz Kaczorowski
Journal:  Hypertension       Date:  2009-12-28       Impact factor: 10.190

Review 5.  Home Blood Pressure Measurements Will Not Replace 24-Hour Ambulatory Blood Pressure Monitoring.

Authors:  Paolo Verdecchia; Fabio Angeli; Giovanni Mazzotta; Giorgio Gentile; Gianpaolo Reboldi
Journal:  Hypertension       Date:  2009-08       Impact factor: 10.190

Review 6.  The 2010 Canadian Hypertension Education Program recommendations for the management of hypertension: part I - blood pressure measurement, diagnosis and assessment of risk.

Authors:  Robert R Quinn; Brenda R Hemmelgarn; Raj S Padwal; Martin G Myers; Lyne Cloutier; Peter Bolli; Donald W McKay; Nadia A Khan; Michael D Hill; Jeff Mahon; Daniel G Hackam; Steven Grover; Thomas Wilson; Brian Penner; Ellen Burgess; Finlay A McAlister; Maxime Lamarre-Cliche; Donna McLean; Ernesto L Schiffrin; George Honos; Karen Mann; Guy Tremblay; Alain Milot; Arun Chockalingam; Simon W Rabkin; Martin Dawes; Rhian M Touyz; Kevin D Burns; Marcel Ruzicka; Norman R C Campbell; Michel Vallée; G V Ramesh Prasad; Marcel Lebel; Sheldon W Tobe
Journal:  Can J Cardiol       Date:  2010-05       Impact factor: 5.223

7.  Automated blood pressure measurement in routine clinical practice.

Authors:  Martin G Myers
Journal:  Blood Press Monit       Date:  2006-04       Impact factor: 1.444

8.  Validation of the Microlife Watch BP Office professional device for office blood pressure measurement according to the International protocol.

Authors:  George S Stergiou; Dimitris Tzamouranis; Athanasios Protogerou; Efthimia Nasothimiou; Christos Kapralos
Journal:  Blood Press Monit       Date:  2008-10       Impact factor: 1.444

9.  Conventional versus automated measurement of blood pressure in primary care patients with systolic hypertension: randomised parallel design controlled trial.

Authors:  Martin G Myers; Marshall Godwin; Martin Dawes; Alexander Kiss; Sheldon W Tobe; F Curry Grant; Janusz Kaczorowski
Journal:  BMJ       Date:  2011-02-07

10.  The BpTRU automatic blood pressure monitor compared to 24 hour ambulatory blood pressure monitoring in the assessment of blood pressure in patients with hypertension.

Authors:  Linda Beckett; Marshall Godwin
Journal:  BMC Cardiovasc Disord       Date:  2005-06-28       Impact factor: 2.298

View more
  2 in total

1.  Blood Pressure Measurement Modalities: A Primer for Busy Practitioners.

Authors:  L Allen Kindman; J Rick Turner; John Lee
Journal:  J Clin Hypertens (Greenwich)       Date:  2015-11-12       Impact factor: 3.738

2.  Comparisons between different blood pressure measurement techniques in patients with chronic kidney disease.

Authors:  Shahrokh Ezzatzadegan Jahromi; Ghasem Haghighi; Jamshid Roozbeh; Vahid Ebrahimi
Journal:  Kidney Res Clin Pract       Date:  2019-06-30
  2 in total